Sharp AE-A18 (serv.man12) Service Manual ▷ View online
25
AH/AY-AP18DR
AH/AY-AP24DR
AH/AY-AP24DR
Table Y-7
AY-AP18DR
7
~
42˚C
ON
-2
~
45˚C
ON
~
7˚C , 42˚C
~
OFF
~
-2˚C , 45˚C
~
OFF
0.3V
~
4.5V
ON
~
0.3V , 4.5V
~
ON
0.3V
~
4.5V
ON
~
0.3V , 4.5V
~
ON
~
0.3V , 4.5V
~
OFF
0.3V
~
4.5V
OFF
~
0.3V , 4.5V
~
OFF
0.3V
~
4.5V
OFF
AH-AP18DR
7
~
42˚C
ON
-2
~
45˚C
ON
~
7˚C , 42˚C
~
OFF
~
-2˚C , 45˚C
~
OFF
0.3V
~
4.5V
ON
~
0.3V , 4.5V
~
ON
0.3V
~
4.5V
ON
~
0.3V , 4.5V
~
ON
~
0.3V , 4.5V
~
OFF
0.3V
~
4.5V
OFF
~
0.3V , 4.5V
~
OFF
0.3V
~
4.5V
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
BLUE
Out Fan(JP18)
TEST(JP8)
Cluster(JP19)
Dry Fan(JP11)
31
Sweat(JP3)
Hot Keep(JP2)
OPEN
21
Power On Start(JP5)
Wireless(JP4)
MODEL SELECTION(AN4 input voltage)
GREEN
ON
ON
OFF
ON
OFF
ON
1000
rpm
OFF
ON
OFF
ON
OFF
OFF
CT INPUT(AN2 input voltage)
BLUE
ON
OFF
11
FEED BACK CIRCUIT
AN3( )
1
FLICK
OFF
OFF
OFF
OPEN
OFF
OFF
OFF
ON
ON
ON
ON
Compressor
02
Room temp.
Pipe temp.
Indoor
Fan
Louver
FAN HIGH
FAN AUTO
CLUSTER
Outdoor
fan
4-way
valve
Power
STEP
No
Buzzer
Lamps
Cluster
Selector
RED
YELLOW
FAN SOFT
FAN LOW
OFF
41
DEICE 1
DEICE 2
Louver Collection(AN5 input voltage)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
51
Pipe 1
Pipe 2
Cooling mode FAN speed Collection(AN6 input voltage)
OFF
OFF
OFF
ON
OFF
OFF
OFF
61
EEPROM
Micro SW
Heating mode FAN speed Collection(AN6 input voltage)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
71
OFF
OFF
EEPROM VERSION(UPPER 4bit)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
81
OFF
OFF
CLOSE
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
EEPROM VERSION(LOWER 4bit)
STEP
No
Buzzer
Lam
p
s
Cluster
Outdoor
Indoor
Fan
Louver
RED
YELLOW
FAN SOFT
FAN LOW
FAN HIGH
FAN AUTO
CLUSTER
Power
Selector
02
Room temp.
Pipe temp.
ON
ON
ON
ON
BLUE
OFF
OFF
OFF
OFF
OPEN
11
FEED BACK CIRCUIT
CT INPUT(AN2 input voltage)
BLUE
ON
OFF
ON
1000
rpm
OFF
OFF
OFF
OPEN
FLICK
21
Power On Start(JP5)
Wireless(JP4)
MODEL SELECTION(AN4 input voltage)
GREEN
ON
ON
OFF
31
Sweat(JP3)
Hot Keep(JP2)
Out Fan(JP18)
TEST(JP8)
Cluster(JP19)
Dry Fan(JP11)
OFF
OFF
OFF
OFF
41
DEICE 1
DEICE 2
Louver Collection(AN5 input voltage)
OFF
OFF
OFF
OFF
51
Pipe 1
Pipe 2
Cooling mode FAN speed Collection(AN6 input voltage)
OFF
OFF
OFF
OFF
OFF
61
EEPROM
Micro SW
Heating mode FAN speed Collection(AN6 input voltage)
OFF
OFF
OFF
OFF
OFF
ON
71
OFF
OFF
EEPROM VERSION(UPPER 4bit)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
81
OFF
OFF
CLOSE
OFF
OFF
OFF
OFF
OFF
OFF
EEPROM VERSION(LOWER 4bit)
0.1V
~
4.9V
ON
-0.1V , 4.9V
~
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
AN3( 1)
0.1V
~
4.9V
ON
-0.1V , 4.9V
~
OFF
AH/AY-AP18DR
AH/AY-AP24DR
AH/AY-AP24DR
26
20.
Diagnosis procedure
When indoor fan motor is out of order or compressor lock occurs, the compressor, indoor fan motor, outdoor
fan motor, and louver are all stopped and the operation LED(red) turns on or off synchronously with the timimg
of the timer LED.
When the thermistor for room temperature or pipe temperature is open or short state, the operation LED turns
on or off synchronously with the timing of the timer LED by pushing continously for more than 5 seconds
"AUX." button during suspension of operation.
When indoor fan motor is out of order or compressor lock occurs, the compressor, indoor fan motor, outdoor
fan motor, and louver are all stopped and the operation LED(red) turns on or off synchronously with the timimg
of the timer LED.
When the thermistor for room temperature or pipe temperature is open or short state, the operation LED turns
on or off synchronously with the timing of the timer LED by pushing continously for more than 5 seconds
"AUX." button during suspension of operation.
Timing chart of Timer LED and Operation LED of DIAGNOSIS PROCEDURE.
When "OI" button the remote controller or "AUX." button in the unit is pushed, the unit is free from
DIAGNOSIS PROCEDURE.
When "OI" button the remote controller or "AUX." button in the unit is pushed, the unit is free from
DIAGNOSIS PROCEDURE.
When the louver unit is not properly installed, all lamps on the indicator panel will blink, operation are all stop
and Remote signal is not accept.
and Remote signal is not accept.
Indoor
fan motor
fan motor
Comp.-lock
Thermistor
short state
short state
Thermistor
open state
open state
Timer
LED
LED
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Operation
LED
LED
Operation
LED
LED
Operation
LED
LED
Operation
LED
LED
1sec.
1sec.
4sec.
27
AH/AY-AP18DR
AH/AY-AP24DR
AH/AY-AP24DR
TROUBLESHOOTING GUIDE OF CONTROL CIRCUIT
measure the secondary voltage
of transformer.
of transformer.
YES
NO
YES
NO
The machine does not function
at all with remote controller and
switch on the indoor unit.
at all with remote controller and
switch on the indoor unit.
Using a tester, measure the
voltage between anodes of D1
and D2 on PWB ass'y.
voltage between anodes of D1
and D2 on PWB ass'y.
Is the measured value
approx. 17.5 Vac ?
Replace the PWB with a new
one.
one.
Is the WPE1
open circuit ?
Replace the fuse and varistor
with new ones.
with new ones.
Replace the transformer with
a new one.
a new one.
OK
FAIL
Check the cleaning
switch 2(1), CN9, CN8
and lead wires.
Replace the cleaning switch 2(1).
(or reset connector)
(or reset connector)
AH/AY-AP18DR
AH/AY-AP24DR
AH/AY-AP24DR
28
YES
NO
NO
YES
The machine does not function
with remote controller
with remote controller
Push button "O/I" on the
wireless remote controller.
wireless remote controller.
Is transmitting
indicator of the remote
controller active ?
Is indicator lamp of
indoor unit proper ?
Replace the
PWB with a
new one.
PWB with a
new one.
Does beep sound
from the indoor unit ?
Using a tester,
measure the voltage
between terminals
of resistor R26
on the PWB ass'y.
measure the voltage
between terminals
of resistor R26
on the PWB ass'y.
Push the button "O/I".
Are batteries of the
wireless remote controller
proper ?
Replace the batteries
with new ones.
with new ones.
Replace the wireless
remote controller.
remote controller.
When the signal is
received, does the voltage
change ?
Replace the PWB with a new
one.
one.
PWB is normal.
Inspect the outdoor unit.
Inspect the outdoor unit.
NO
YES
NO
YES
Replace the photo
detector unit with a new
one.
detector unit with a new
one.
NO
YES