1.1 General Guidelines
1.1.1 Leakage Current Cold Check
1.1.2 Leakage Current Hot Check (See Figure 1 .)
TOP
PREVIOUS
NEXT
1.1 General Guidelines
TOP
PREVIOUS
NEXT
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts
which have been overheated or damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation
papers shields are properly installed.
3. After servicing, make the following leakage current checks to prevent the customer from
being exposed to shock hazards.
1.1.1 Leakage Current Cold Check
1.1.2 Leakage Current Hot Check (See Figure 1 .)
TOP
PREVIOUS
NEXT
1.1.1 Leakage Current Cold Check
TOP
PREVIOUS
NEXT
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each
exposed metallic cabinet part on the equipment such as screwheads, connectors, control shafts,
etc. When the exposed metallic part has a return path to the chassis,the reading should be
between 1M
etc. When the exposed metallic part has a return path to the chassis,the reading should be
between 1M
Ω
and 5.2M
Ω
.
When the exposed metal does not have a return path to the chassis, the reading must be
.
Figure 1
TOP
PREVIOUS
NEXT
1.1.2 Leakage Current Hot Check (See
Figure
1
.)
TOP
PREVIOUS
NEXT
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this
check.
2. Connect a 1.5k
Ω
, 10 watts resistor, in parallel with a 0.15
μF capacitors, between each
exposed metallic part on the set and a good earth ground such as a water pipe, as shown in
Figure 1
.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across
the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester
(Simpson Model 229 or equivalent) may be used to make the hot checks, leakage current must
not exceed 1/2 milli amp. In case a measurement is outsideof the limits specified, there is a
possibility of a shock hazard, and the equipment should be repaired and rechecked before it is
returned to the customer.
not exceed 1/2 milli amp. In case a measurement is outsideof the limits specified, there is a
possibility of a shock hazard, and the equipment should be repaired and rechecked before it is
returned to the customer.