DOWNLOAD Panasonic TY-42TM5H / TY-37TM5H Service Manual ↓ Size: 801.87 KB | Pages: 10 in PDF or view online for FREE

Model
TY-42TM5H TY-37TM5H
Pages
10
Size
801.87 KB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
ty-42tm5h-ty-37tm5h.pdf
Date

Panasonic TY-42TM5H / TY-37TM5H Service Manual ▷ View online

3 Conductor Views
3.1.
H-Board (TY-37/42TM5H)
A
B
C
D
E
F
G
H
I
1
2
3
4
5
6
H-BOARD(FOIL SIDE)
TXN/H10JKS-K (FOR TY-42TM5H)
TXN/H10KJS-K (FOR TY-37TM5H)
TY-42TM5H H-BOARD TXN/H10JKS-K
TY-37TM5H H-BOARD TXN/H10KJS-K
TY-42TM5H H-BOARD TXN/H10JKS-K
TY-37TM5H H-BOARD TXN/H10KJS-K
JK3311
IC3699
H1
H2
TNPA2247
2 H
1
10
19
26
18
9
SEE
REVERSE
FOR ORDER NO.
8
5
4
1
A1
A2
B2
B1
B25
B24
A24
A25
A1
A2
B2
B1
B20
B19
A20
A19
TY-42TM5H / TY-37TM5H
5
A
B
C
D
E
F
G
H
I
1
2
3
4
5
6
Parts Location
H-BOARD (COMPONENT SIDE)
IC
IC3451 
B-2
IC3699
D-2
Q3451 
A-2
Q3452 
B-3
Q3453 
A-2
Q3454 
B-2
Q3455 
B-2
Q3456 
B-3
Q3457 
B-2
Q3458 
A-2
Q3459 
B-3
TRANSISTOR
TY-42TM5H H-BOARD TXN/H10JKS-K
TY-37TM5H H-BOARD TXN/H10KJS-K
TY-42TM5H H-BOARD TXN/H10JKS-K
TY-37TM5H H-BOARD TXN/H10KJS-K
H-BOARD(COMPONENT SIDE)
TXN/H10JKS-K (FOR TY-42TM5H)
TXN/H10KJS-K (FOR TY-37TM5H)
C3451
C3452
C3453
C3454
Q3451
C3455
Q3452
C3456
Q3453
C3457
Q3454
C3458
Q3455
C3459
Q3456
Q3457
Q3458
Q3459
C3460
C3461
C3462
C3463
C3464
C3465
C3466
C3467
C3468
D3451
D3452
R3451
R3452
R3453
R3454
R3455
R3456
R3457
R3458
IC3451
R3459
R3460
R3461
R3462
R3463
R3464
R3465
R3466
R3467
R3468
R3469
R3470
R3471
R3472
R3473
R3474
R3475
R3476
R3477
R3478
R3479
R3480
R3481
R3482
R3483
R3484
JK3311
R3485
R3486
R3487
R3488
R3489
R3490
R3491
R3492
R3493
R3494
R3495
R3496
R3497
R3498
R3499
IC3699
C3506
H1
H2
JS28
JS29
JS30
R3521
R3522
L3451
L3452
L3453
L3454
L3455
L3456
L3457
L3458
L3459
L3460
TNPA2247
2 H
TY-42TM5H / TY-37TM5H
6
Components identified by     mark have special characteristics important for safety.
When replacing any of these components, use only manufacture's specified parts.
Important Safety Notice
Notes:
1. Resistor
All resistors are cabon 1/4W resistor, unless marked as follows:
Unit of resistance is OHM [
W] (K=1,000, M=1,000,000).
: Nonflammable
: Metal Oxide
: Solid
: Metal Film
: Wire Wound
: Fuse:
2. Capacitor
All capacitors are ceramic 50V capacitor, unless marked as follows:
Unit of capacitance is 
mF, unless otherwise noted.
: Temperature Compensation
: Electrolytic
: Polyester
: Bipolar
: Metalized Polyester
: Dipped Tantalum
: Polypropylene
: Z-Type
3. Coil
Unit of inductance is 
mF, unless otherwise noted.
4. Test Point
: Test Point position
5. Earth Symbol
: Chassis Earth (Cold)
: Line Earth (Hot)
6. Voltage Measurement
Voltage is measured by a DC voltmeter.
Conditions of the measurement are the following:
Power Source ................................................... AC 120V, 50/60Hz
 (North America model)/AC220-240V,
 50/60Hz (Except North America)
Receiving Signal ............................................... Colour Bar signal (RF)
All customer's controls ...................................... Maximum positions
7. Number in red circle indicates waveform nember.
(See waveform pattern table.)
8. When arrow mark (     ) is found, connection is easily found from the direction of arrow
9.   Indicates the major signal flow.
: Video
Audio
10. This schematic diagram is the latest at the time of printing and subject to change without 
notice.
+
-
M
m
T
Z
NP
TY-37TM5H/TY-42TM5H
Schematic Diagram Notes
Remarks:
1. The Power Circuit contains a circuit area which uses a separate power supply to isolate the 
earth connection.
The circuit is defined by HOT and COLD indications in the schematic diagram. Take the 
follwing precautions.
All circuits, except the Power Circuit, are cold.
Precautions
a. Do not touch the hot part or the hot and cold parts at the same time or you may 
be shocked.
b. Do not short- circuit the hot and cold circuits or a fuse may blow and parts may 
break.
c. Do not connect an instrument, such as an oscilloscope, to the hot and cold 
circuits simultaneously or a fuse may blow.
    Connect the earth of instruments to the earth connection of the circuit being 
measured.
d. Make sure to disconnect the power plug before removing the chassis.
2. Following diodes are interchangeable.
MA150- MA162 (Replacement part)
TY-37TM5H/TY-42TM5H
Schematic Diagram Notes
4 Block and Schematic Diagrams
4.1.
Schematic Diagram Notes
TY-42TM5H / TY-37TM5H
7
4.2.
H-Board (TY-37/42TM5H) Block and Schematic Diagrams
TY-37TM5H/TY-42TM5H
H-Board Block and Schematic Diagrams
TY-37TM5H/TY-42TM5H
H-Board Block and Schematic Diagrams
TY-42TM5H / TY-37TM5H
8
Page of 10
Display

Click on the first or last page to see other TY-42TM5H / TY-37TM5H service manuals if exist.