DOWNLOAD Panasonic KX-TGF310RUM / KX-TGF320RUM / KX-TGF320UCM / KX-TGFA30RUM Service Manual ↓ Size: 9.24 MB | Pages: 116 in PDF or view online for FREE

Model
KX-TGF310RUM KX-TGF320RUM KX-TGF320UCM KX-TGFA30RUM
Pages
116
Size
9.24 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / DIGITAL CORDED/ CORDLESS PHONE
File
kx-tgf310rum-kx-tgf320rum-kx-tgf320ucm-kx-tgfa30ru.pdf
Date

Panasonic KX-TGF310RUM / KX-TGF320RUM / KX-TGF320UCM / KX-TGFA30RUM Service Manual ▷ View online

57
KX-TGF310RUM/KX-TGF320RUM/KX-TGF320UCM/KX-TGFA30RUM
10.1.4. How to Replace the Base unit LCD
LCD HOLDER
LCD PLATE
REFLECTOR SHEET
**colour is Black (PNHX1689YA/Z1)
*PROCESS IT AS SHOWN IN FIGURE.
*PROCESS IT AS SHOWN IN FIGURE.
*PROCESS IT AS SHOWN IN FIGURE.
REVERSE.
LED P.C.B.
58
KX-TGF310RUM/KX-TGF320RUM/KX-TGF320UCM/KX-TGFA30RUM
LCD
Attach LCD P.C.B  under conditions to push edge face.
LCD P.C.B.
FFC/8
View A
STICK IT ALONG THESE LINES.
SHEET/LCD
View A
*INSERT FFC IN THE HOLE OF COVER/LCD.
GRILL/LCD
COVER/LCD
59
KX-TGF310RUM/KX-TGF320RUM/KX-TGF320UCM/KX-TGFA30RUM
10.2. How to Replace the Handset LCD
Note:
The illustrations are simplified in this page.
They may differ from the actual product.
Peel off the FFC (Flexible Flat Cable) from 
the LCD, in the direction of the arrow. Take 
care to ensure that the foil on the P.C. board 
is not damaged.
Fit the heatseal of a new LCD.
Heatweld with the tip of the soldering 
iron about 5 to 8 seconds 
(in case of 60W soldering iron).
0.2 mm
0.2 mm
P. C. board
New LCD
Tip of Soldering Iron
(Part No. PQZZ430PIR)
Rubber of Soldering Iron
(Part No. PQZZ430PRB)
If interval tolerance between center lines
is less than 0.2 mm, it is o.k.
Horizontal Interval
Tolerance
Vertical Interval
Tolerance
OK
NG
NG
NG
(Horizontal interval tolerance is
 more than 0.2 mm.)
(Vertical interval tolerance is
 more than 0.2 mm.)
(Inclined)
60
KX-TGF310RUM/KX-TGF320RUM/KX-TGF320UCM/KX-TGFA30RUM
11 Measurements and Adjustments
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in 
 Troubleshooting Guide (P.30)
11.1. Equipment Required
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
Hewlett Packard, 53131A is recommended.
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
This equipment may be useful in order to precisely adjust like a mass production.
11.2. The Setting Method of JIG (Base Unit)
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: Refer to parts list of Fixtures 
and Tools (P.116).
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
11.2.1. Connections (Base Unit)
 Connect the AC adaptor.
 Connect the JIG Cable GND (black).
 Connect the JIG Cable RX (red) and TX (yellow).
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
) New value (k)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
Base unit P. C. board
URX
UTX
GND
AC adaptor
1
DC JACK
UTX (yellow)
3
2
3
GND (black)
URX (red)
To Serial Port
(COM port 1*)
JIG Cable
PC
Page of 116
Display