Panasonic KX-TGA915EXS Service Manual ▷ View online
21
KX-TGA915EXS
Cross Reference:
Check Point (USB Adaptor) (P.22)
22
KX-TGA915EXS
10.2. Troubleshooting by Symptom (USB Adaptor)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not.
(*1) or not.
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to Check Point (USB Adaptor) (P.22)
level in detail.
(*2) Refer to Check Point (USB Adaptor) (P.22)
10.2.1. Check Point (USB Adaptor)
Please follow the items below when BBIC, EEPROM or Flash ROM is replaced.
Note:
After the measuring, suck up the solder of TP.
*: PC Setting (P.28) is required beforehand.
The connections of simulator equipments are as shown in Adjustment Standard (USB Adaptor) (P.30).
*: PC Setting (P.28) is required beforehand.
The connections of simulator equipments are as shown in Adjustment Standard (USB Adaptor) (P.30).
Items
Check
Point
Procedure
Check or
Replace Parts
(A)* 1.8 V Supply Adjustment
+1.8 V
1. Confirm that the voltage between test point +1.8 V and GND is 1.8 V ±0.02 V.
2. Execute the command “bandgap”, then check the current Value.
3. Adjust the 1.8 V voltage of +1.8 V executing command “bandgap XX” (XX is
2. Execute the command “bandgap”, then check the current Value.
3. Adjust the 1.8 V voltage of +1.8 V executing command “bandgap XX” (XX is
the value).
Q2, C4, R26
(B) 3.2 V Supply Confirmation
+3.2 V
1. Confirm that the voltage between test point +3.2 V and GND is 3.35 V ±0.3 V
(Backlight is OFF)/4.3 V ± 0.3 V (Backlight is ON).
IC4, C51, C37,
C1, C2, C3
(C) 2.5 V Supply Confirmation
+2.5 V
1. Confirm that the voltage between test point +2.5 V and GND is 3.0 V ±0.1 V.
IC9, C50
(D)*
BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC1, R59, R60,
R42, D1, Q9,
R53, C25,
C28, C20,
C21, R52,
C26, C23,
C28, C20,
C21, R52,
C26, C23,
R27, C24, X1,
C29, C27, Q8,
R49, R50,
R51, R39,
R51, R39,
R40, Q7, R41,
D2, IC2, R8,
R38
(E)* Flash ROM or EEPROM
Confirmation
-
1. Flash ROM or EEPROM Confirmation (Execute the command
“ChkTGA915PEXrevYY.bat”).
YY: revision number
YY: revision number
2. Confirm the returned checksum value.
3. The checksum is displayed in the last output line.
3. The checksum is displayed in the last output line.
Note:
“YY” and “checksum” vary depending on the country version. You can find them
in the batch file, PQZZ- mentioned in JIG and PC (P.28).
in the batch file, PQZZ- mentioned in JIG and PC (P.28).
IC5, IC1, R9,
R10, R11,
C42, Q4, R12
(F)*
BBIC Clock Adjustment
RFCLK
1. Apply 2.5 V between D (+) and D (-) with DC power.
2. Execute the command “conttx”.
3. Input Command “rdeeprom 00 01 01”, then you can confirm the current value.
4. Adjust the frequency of RFCLK executing the command “setfreq 00 xx (where
2. Execute the command “conttx”.
3. Input Command “rdeeprom 00 01 01”, then you can confirm the current value.
4. Adjust the frequency of RFCLK executing the command “setfreq 00 xx (where
xx is the value)” so that the reading of the frequency counter is 10.368000 MHz
±10 Hz.
±10 Hz.
IC1, X1, C35,
R12, IC20,
R127, R128
23
KX-TGA915EXS
(G)*
Transmitted Power
Confirmation
-
Remove the Antenna before starting step from 1 to 4.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030405
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL = -70 dBm
• RFPI: 0102030405
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL = -70 dBm
2. Execute the command “regcmd60 01 02 03 04 05”.
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is 19 dBm ~ 24 dBm.
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is 19 dBm ~ 24 dBm.
IC9, IC6, IC7,
R54, C31,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
R19, R20
(H)*
Modulation Check and
Adjustment
-
Follow steps 1 to 3 of (G).
4.Confirm that the B-Field Modulation is -350 ~ -400/+320 ~ +370 kHz/div using
data type Fig 31.
5.Adjust the B-Field Modulation if required. (Execute the command “Readmod”
and “wrtmod xx”, where xx is the value.)
data type Fig 31.
5.Adjust the B-Field Modulation if required. (Execute the command “Readmod”
and “wrtmod xx”, where xx is the value.)
IC9, IC6, IC7,
R54, C31,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
R19, R20
(I)*
Frequency Offset
Confirmation
-
Follow steps 1 to 3 of (G).
4.Confirm that the frequency Offset is < ±45 kHz.
IC9, IC6, IC7,
R54, C31,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
R19, R20
(J)*
Frequency Drift
Confirmation
-
Follow steps 1 to 3 of (G).
4.Confirm that the frequency Drift is < ±30 kHz/ms.
IC9, IC6, IC7,
R54, C31,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
R19, R20
(K)*
Sensitivity Receiver
Confirmation
-
Follow steps 1 to 3 of (G).
4.Set DECT tester power to -90 dBm.
5.Confirm that the BER is < 1000 ppm.
5.Confirm that the BER is < 1000 ppm.
IC9, IC6, IC7,
R54, C31,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
R19, R20
(L)*
Timing Confirmation
-
Follow steps 1 to 3 of (G).
4.Confirm that the Timing accuracy is < ±2.0 ppm.
IC9, IC6, IC7,
R54, C31,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
R19, R20
(M)* RSSI Level Confirmation
-
Follow steps 1 to 3 of (G).
4.Set DECT tester power to -81 dBm.
5.Execute the command “readrssi”.
6.Confirm that the returned value is 1D ±8 (hex).
7.Set DECT tester power to -63 dBm.
8.Execute the command “readrssi”.
9.Confirm that the returned value is 27 ±8 (hex).
5.Execute the command “readrssi”.
6.Confirm that the returned value is 1D ±8 (hex).
7.Set DECT tester power to -63 dBm.
8.Execute the command “readrssi”.
9.Confirm that the returned value is 27 ±8 (hex).
IC9, IC6, IC7,
R54, C31,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
R19, R20
Items
Check
Point
Procedure
Check or
Replace Parts
24
KX-TGA915EXS
(N)*
Power RAMP
Confirmation
-
Follow steps 1 to 3 of (G).
4.Confirm that Power RAMP is matching.
IC9, IC6, IC7,
R54, C31,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
C32, C50,
C45, R21,
R22, R58,
R13, R14,
R15, R16,
R17, R18,
R19, R20
Items
Check
Point
Procedure
Check or
Replace Parts