KX-TG1105RUJ / KX-TG1105R UM / KX-TG1106R UM / KX-TGA110RUJ / KX-TGA110RUM
15.3. Telephone Line Interface
<Function>
 
·
 
Bell signal detection
 
·
 
Clip signal detection
 
·
 
ON/OFF hook circuit
 
·
 
Audio circuits
Bell & Clip (: Calling Line Identification Presentation: Caller ID) signal detection:
In the standby mode, Q2 is open to cut the DC loop current and decrease the ring load.
When ring voltage appears at the TP3 (A) and TP40 (B) leads (when the telephone rings), the signal is transferred as follows;
 
·
 
A
C4
R2
R29
IC2 (DLP) [BELL & CLIP]
 
·
 
B
C3
R1
R30
IC2 (DLP) [BELL & CLIP]
ON/OFF hook circuit:
In the standby mode, Q2 is open, and connected as to cut the DC loop current and to cut the voice signal. The unit is
consequently in an off-hook condition.
When IC2 detects a ring signal or press the TALK Key onto the handset, Q3 turns on and then Q2 turns on, thus providing an
off-hook condition (DC current flows through the circuit) and the following signal flow makes the loop current.
 
·
 
A
D2
Q2
R8
Q6
R19
R20
D2
B [OFF HOOK]
Audio circuits:
Refer to SIGNAL ROUTE (P.50).
15.4. Transmitter/Receiver
Base Unit and Handset mainly consist of RF Module and DECT BBIC.
Base Unit and Handset transmit/receive voice signal and data signal through the antenna on carrier frequency.
Signal Path:
*Refer to SIGNAL ROUTE (P.50).
15.4.1. Transmitter Block
The voice signal input from the TEL LINE interface goes to RF Module (IC3) through DECT BBIC (IC2) as shown in BLOCK
DIAGRAM (BASE UNIT) 
(P.42)
The voice signal passes through the analog part of IC2 where it is amplified and converted to a digital audio stream signal. The
burst switch controller processes this stream performing encryption and scrambling, adding the various other fields to produce
the GAP (Generic Access Profile) standard DECT frame, assigning to a time slot and channel etc.
In IC3, the carrier frequency is changing, and frequency modulated RF signal is generated and amplified, and radiated from
antenna. Handset detects the voice signal or data signal in the circuit same as the following explanation of Receiver Block.
15.4.2. Receiver Block
The signal of 1.9 GHz band (1.881792 GHz ~ 1.897344 GHz) which is input from antenna is input to IC3 as shown in BLOCK
DIAGRAM (BASE UNIT) 
(P.42).
In IC3, the signal of 1.9 GHz band is demodulated, and goes to IC2 as GAP (Generic Access Profile) standard DECT frames.
It passes through the decoding section burst switch controller where it separates out the frame information and performs de-
encryption and de-scrambling as required. It then goes to the DSP section where it is turned back into analog audio. This is
amplified by the analog front end, and goes to the TEL LINE Interface.
15.5. Pulse Dialling
During pulse dialing the hookswitch (Q2, Q3) is used to generate the pulses using the HOOK control signal, which is set high
during pulses. To force the line impedance low during the “pause” intervals between dial pulses, the PULSE_DIAL signal turns
on Q7.
46
KX-TG1105RUJ / KX-TG1105R UM / KX-TG1106R UM / KX-TGA110RUJ / KX-TGA110RUM
16 BLOCK DIAGRAM (HANDSET)
33
CPU
IC4
IC3
BBIC
A/D
D/A
Analog
Front
End
Speech 
Encoding
Speech 
Decoding
DSP
ADPCM
Codec
Filter
BMC
RF
Interface
MIC
EEPROM
IC2
SDA
SCL
66
67
5
6
SYRI
RSSI
SYEN
RXDA
TXDA
16
12
48
23
13
RF
Module
ANT
BATTERY
TERMINAL
Battery+
Battery-
CHARGE
CIRCUIT
CHARGE
CHARGE DETECT
SWITCHED
SUPPLY
CHARGE
CONTACTS
TP5
4.0V
VDDBAT
VDDLR
SWITCH
31
XTAL
10.368
MHz
KEYPAD
COLUMNS
RINGER
ROWS
LCD
14 Seg
Display
ON SWITCH
38
27
26
36
37
28
pin 2, 5~9
COM 0~5
segment 0~29
pin1, 90~100, 87, 78~84,
72~76, 61, 62, 56~58
EARPIECE
42
41
45
17~21
4.0V
Q104
4.0V
LED102
LED101
Q4
53~55, 59, 60
34
70
88
Burst 
Encoding
Burst 
Decoding
+
TP6
D3
46
19
4
5
12
10
KX-TGA110 BLOCK DIAGRAM (HANDSET)
47
KX-TG1105RUJ / KX-TG1105R UM / KX-TG1106R UM / KX-TGA110RUJ / KX-TGA110RUM
17 CIRCUIT OPERATION (HANDSET)
17.1. Outline
Handset consists of the following ICs as shown in BLOCK DIAGRAM (HANDSET) (P.47).
 
·
 
DECT BBIC (Base Band IC): IC4
 − 
All data signals (forming/analyzing ACK or CMD signal)
 − 
All interfaces (ex: Key, Detector Circuit, Charge, DC/DC Converter, EEPROM, LCD)
 
·
 
RF Module: IC3
 − 
PLL Oscillator
 − 
Detector
 − 
Compress/Expander
 − 
Amplifier for transmission and reception
 
·
 
EEPROM: IC2
 − 
Temporary operating parameters (for RF, etc.)
17.2. Power Supply Circuit/Reset Circuit
Circuit Operation:
When power on the Handset, the voltage is as follows;
BATTERY (2.2 V ~ 2.6V: TP3)
4.0V
IC3 (6, 25), D3
IC4 (37)
IC4 (39, 63) (2.65V)
The Reset signal generates R19, C23 and 2.65V.
17.3. Charge Circuit
Circuit Operation:
When charging the handset on the Base Unit, the charge current is as follows;
DC+ (5.5V ~ 6V)
D4
R43, R44
CHARGE+ (Base)
CHARGE+ (Handset)
L4
Q2
F1
BATTERY+... Battery...
BATTERY-
R21
GND
L5
CHARGE- (Handset)
CHARGE- (Base)
GND
DC- (GND)
In this way, the BBIC on Handset detects the fact that the battery is charged.
The charge current is controlled by switching Q2 of Handset.
Refer to Fig.101 in Power Supply Circuit (P.44).
17.4. Battery Low/Power Down Detector
Circuit Operation:
“Battery Low” and “Power Down” are detected by BBIC which check the voltage from battery.
The detected voltage is as follows;
 
·
 
Battery Low
Battery voltage: V (Batt) < 2.3V
The BBIC detects this level and “
” starts flashing and “battery alarm” starts ringing.
 
·
 
Power Down
Battery voltage: V (Batt) < 2.2V
The BBIC detects this level and power down.