47
|
KX-TCD961GB
TELEPHONE LINE TESTS
1. Connect the tel line from the base under test to the line simulator.
2. Send batch file “OFFHOOK”.
3. Check if the green “In-Use” LED is on.
4. Set the line current to 40 mA on the line simulator.
5. Send batch file “ONHOOK”.
6. Check that the line current is 0 ± 0.5 mA.
7. Check if the green “In-Use” LED is off.
8. Send batch file “OFFHOOK”.
9. Check the DC Voltage on TP45. It must be 9.5 ± 0.5V.
10. Send batch file “LINIMP 1”.
11. Check the DC Voltage on TP45. It must be < 3.0V.
12. Send batch file “LINIMP 0”.
13. Send batch file “PULDIAL”.
14. Observe on the line simulator current meter that 5 dial pulses are output causing the current to reduce to approx.
      20mA.
15. Send batch file “STRTDTMF”.
16. Check on the scope that a DTMF waveform is output on that tel line.
17. Send batch file “STOPDTMF”.
18. Disconnect the tel line from the base under test to the line simulator.
19. Connect the “Bell” Oscillator to the tel line.
20. Set the “Bell” Oscillator voltage to 30V RMS 23Hz.
21. Send batch file “RINGDET”.
22. Check that the ringing voltage has been detected (1 = detected).
CHARGE CURRENT TEST
1. Connect the 11V supply to J2 pin 6 (+) and J2 pin 5 (–).
2. Connect the ammeter with a series load resistor of 56
/2 W to J3 (+) and J4 (–).
3. Switch on the 11V supply.
4. Check the Charge Voltage to J3 and J4 9.5 ± 0.5 V.
5. Switch off the 11V supply.
6. Connect the 11V supply to the “11V Supply” sockets on the test jig.
|
48
|
KX-TCD961GB
CHECK PROCEDURE (HANDSET)
TEST EQUIPMENT REQUIRED AND EQUIPMENT SETUP
(a) CMD60
(b) Power Supply (12V 1A)
(c) Digital MultiMeter
(d) Oscilloscope
(e) Frequency Counter
(f) Computer (PC): Set the computer to the MS-DOS mode. Type: SET-COM1.
(g) Test software (Batch Files)
Connect a 3.9V supply to the board J3 (+), J4 (–).
Connect the computer serial link to the Test Fixture J6 (+), J8 (–).
INITIAL POWER + BBIC TESTS
1. Turn on the 3.9V supply.
2. Press the “Power-on” button.
3. Check for a “beep” and approx 80 mA current on the 3.9V supply.
4. Check the 3.0V supply voltage (TP2). It must be 3.0 ± 0.2V.
5. Connect RFCLK (TP56) to CH.1 on the scope.
6. Check if the clock waveform is 10,368.000 kHz.
7. Send batch file “SELF TEST”.
SET CLOCK FREQUENCY
1. Send batch file “FIX FREQ”.
2. Connect RFCLK (TP56) to the frequency counter.
3. Send batch file “SET FREQ nn” to set the clock frequency. The default value of nn is 80. Increase the value to
    increase the frequency. The clock frequency must be 10,368.000 kHz ± 0.02 kHz.
TEST MODE:
MANUAL TEST
MODULE TEST
CONFIG MENU
MODULE TEST
PP
RFPI:
DUMMY SLOT:
DUMMY CARRIER:
TRAFFIC SLOT:
TRAFFIC CARRIER:
RF LEVEL:
TRIGGER:
EXP. POWER:
SIGN
RF GENERATOR
0000000010
0
5
2
5
– 55 dBm
RISING SLOPE
30 dBm
SCRAMBLE:
FREQ:
DEVIATION:
SIGNAL:
RF LEVEL:
OFF
1888.704 MHz
288 kHz
00001111
– 40.7 dBm
|
49
|
KX-TCD961GB
QUICK Tx  CHECK
1. Set the CMD60 to MODULE TEST.
2. Send batch file “H”.
3. Confidence check of Power (NTP): must be +20 to +25 dBm.
4. Confidence check of Frequency Offset: must be 0 ± 40 kHz.
5. Confidence check of Deviation of B field Data Type 01010101: must be 207 to 270 kHz.
LOOPBACK TEST
1. Set the CMD60 to MANUAL TEST.
2. Set the CMD60 TRAFFIC CARRIER to 5.
3. Send batch file “TESTMODE”.
4. On the CMD60 press “SETUP CONNECT”.
5. Check Power (NTP): must be +20 to +25 dBm.
6. Press MODULATION.
7. Set Data Type to “Fig.36”.
8. Check the Frequency Drift: must be 0 ± 45 kHz/ms.
9. Check the Frequency Offset: must be 0 ± 40 kHz.
10. Send batch file “WREE 00 51 nm” to adjust the Deviation (Max. ± B Field) with Data Type: 01010101. Increase
      the value nm to increase the Deviation and vice-versa. The least significant digit (m) of the value must be 1 (i.e.
      only the values 31, 41, 51, 61 etc. are allowed). The Deviation must be 202 to 280 kHz.
11. Check the Deviation (Max.  ± B Field) with Data Type “Fig.36”: must be 280 to 370 kHz.
12. Press MENU UP.
13. Press POWER RAMP
14. Check the Burst fits mask.
15. Press MENU UP.
16. Press BER.
17. Note the Sensitivity (reduce the RF LEVEL for a BER of approx. 1000ppm) : RF LEVEL must be < – 90 dBm.
18. Press MENU UP.
19. Press BEARER RELEASE.
      (Note: These tests can be repeated on Traffic Carriers 0 and 9.)
|
50
|
KX-TCD961GB
TROUBLESHOOTING GUIDE
HANDSET: DOES NOT OPERATE.
Yes
No
Yes
No
Yes
No
1
No
Yes
No
Check the battery terminal, PCB 
and battery contact.
Check X1 and the surrounding
area.
Check the IC1 soldering.
Disconnect the AC adaptor of 
the base unit. Are clock 
waveforms output to IC1 pin 10 
of the handset?
Check the power of IC1.
Is it 3.0V?
Supply 3.6V voltage to the PCB
from an external source.
Defective battery contact.
Replace the batteries with fully 
charged ones, and set the power 
switch to ON.  Does "       " flash
on the LCD screen of the
handset?
No
Check the battery voltage.  
Is it more than 3.6V?
Does "    " remain lit, and is the
handset number displayed?
Set the handset power switch to
ON.  Does "    " flash on the LCD
screen of the handset?
Handset:  Insert the batteries.
Base unit:  Connect the AC adaptor and telephone cord.
2
3
Page of 66