33
KX-PRS110RUW/KX-PRS120RUW/KX-PRSA10RUW
9.1.5.
Check Handset Transmission
Cross Reference:
Signal Route (P.15)
9.1.6.
Check Handset Reception
Cross Reference:
How to Check the Handset Speaker or Receiver (P.56).
Signal Route (P.15)
9.1.7.
Check Caller ID
Cross Reference:
Signal Route (P.15)
OK
Check MIC of Handset.
Check CDL TX (HANDSET) in Signal Route.
Check Handset Speaker in How to check the Handset 
Speaker or Receiver
.
OK
Check CDL RX (HANDSET) in Signal Route.
Check Caller ID in Signal Route.
34
KX-PRS110RUW/KX-PRS120RUW/KX-PRSA10RUW
9.1.8.
Bell Reception
9.1.8.1.
Base Unit
9.1.8.2.
Handset
Cross Reference:
Telephone Line Interface (P.12)
Check Link (P.27)
How to Check the Handset Speaker or Receiver (P.56)
9.1.9.
Check TAM Operation (for KX-PRS120 only)
Cross Reference:
Power Supply Circuit (P.11)
Note:
(*1) When replacing FLASH MEMORY (IC601), TAM data need to be written to it. Refer to Base Unit of Things to Do after
Replacing IC or X'tal
 (P.53)
When bell signal is coming, is there bell sound 
signal at BBIC (IC501:CIDINp, CIDINn)?
Check around C103, C104, C105, C106, C107, 
C108, C109, C110, C111, C112, C123, C124, 
R101, R102, R103, R104, R105, R106, R107, R108, 
R109, R110, R111, R112, P101
NO
Does the bell sound from SPEAKER?
Check around SP+, SP- .
When bell signal coming, is there bell sound signal 
at BBIC [IC1 (U8, V8)(U9, V9)] ?
NO
NO
YES
When bell signal coming, is there bell sound signal
at SP+, SP- ?
YES
Check BBIC (IC1), C36, C37
NO
Check cable of SPEAKER and resistance value
of SPEAKER.
Check IC601 and BBIC (IC501) of Base Unit. (*1)
Is there a TAM icon on the Handset display?
Turn on the Answering System.
Check Power Supply Circuit.
NO
NO
YES
Is the voltage of VDD3 of Base Unit about 3.0 V
and VDD1 about 1.8 V, VDD4 about 3.0 V, 
VDD5 about 3.0 V?
YES
35
KX-PRS110RUW/KX-PRS120RUW/KX-PRSA10RUW
9.2.
Troubleshooting by Symptom (Base Unit)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not. 
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to Check Point (Base Unit) (P.35)
9.2.1.
Check Point (Base Unit)
Please follow the items below when BBIC or EEPROM or FLASH is replaced.
Note:
After the measuring, suck up the solder of TP.
*: The Setting Method of JIG (Base Unit) (P.47) is required beforehand.
The connections of simulator equipment are as shown in Adjustment Standard (Base Unit) (P.49).
Symptom
Remedy (*2)
You don’t have DECT Tester.
You have DECT Tester. 
(Model Number: CMD60)
You cannot dial.
Check item (A) - (I), (R).
Check item (A) - (I), (J) - (N), (R).
You cannot hear the caller’s voice.
Check item (A) - (G), (O), (R).
Check item (A) - (G), (J) - (N), (O), (R).
You cannot use the handset a little away from base unit even if the
handset is within range of the base unit.
-
Check item (J) - (N).
The acoustic transmit level is high or low.
Check item (O).
Check item (O).
The acoustic reception level is high or low.
Check item (O).
Check item (O).
Base unit and handset do not link to each other.
Check item (A) - (I).
Check item (A) - (N).
The unit cannot charge.
Check item (P).
Check item (P).
TAM does not work. (for KX-PRS120 only)
Check item (Q).
Check item (Q).
Items
Check 
Point
Procedure
Check or 
Replace Parts
(A)
3.0 V Supply 
Confirmation
VDD3
1. Confirm that the voltage between test point VDD3 and GND is 3.0 V ± 0.2 V.
IC302, R321, 
R322, C341, 
C342 
(B)
1.8 V Supply 
Confirmation
VDD1
1. Confirm that the voltage between test point VDD1 and GND is 1.8 V ± 0.02 V.
2. Execute the command “VDD”, then check the current value.
3. Adjust the 1.8V voltage of VDD1 executing command “VDD XX“(XX is the
value).
Q301, IC501, 
R311, C311, 
C516, C519
(C) Charge Pump 3.0V
Supply Confirmation
VDD5
1. Confirm that the voltage between test point VDD5 and GND is 3.0 V -0.1/+0.3
V. 
IC501, C511
(D) Charge Pump 3.0V
Supply Confirmation
VDD4
1. Confirm that the voltage between test point VDD4 and GND is 3.0 V ± 0.2 V. 
IC501, C509, 
R507
(E)*
BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC501, X501
(F)* EEPROM Confirmation
-
1. EEP-ROM Confirmation (Execute the command "sendchar EPV").
2. Confirm the returned Value. (Value for reference is written at "EEPROM C/
SUM” in Software_Version_Table.xls).
IC501, RA611, 
IC611, C611
(G)* BBIC Clock Adjustment
CKM
1. Confirm that the voltage between testpoint VDD4 and GND is less than 1.0 V.
2. Input Command “ sendchar sfr”, then you can confirm the current value.
3. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
4. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CKM
executing the command “sendchar sfr xx xx (where xx is the value)” so that
the reading of the frequency counter is 10.368000 MHz ± 5 Hz.
IC501, X501, 
C502
(H)* Hookswitch Check with 
DC Characteristics
-
1. Connect Telephone Socket to Tel-simulator which is connected with 600 
.
2. Set line voltage to 48 V and line current to 40mA at off-hook condition of
normal telephone.
3. Execute the command “hookoff”
4. Confirm that the line current is 40 mA ± 5 mA.
5. Execute the command “hookon”.
6. Confirm that the line current is less than + 0.8 mA.
P101, Q141, 
R141, R142, 
Q142, R144, 
R145, D101, 
R161~R167, 
D141, Q161, 
R151, IC501
checksum value
422E
program number
DDR1RN
ex.)
36
KX-PRS110RUW/KX-PRS120RUW/KX-PRSA10RUW
(I) DTMF Generator Check
-
1. Connect Telephone Socket to DTMF tester. (Load=600 
)
2. Link Handset and push dial key.
3. Confirm DTMF character.
4. Confirm that the high Group is -3.0 ± 2 dBm.
5. Confirm that the low Group is-6.0 ± 2 dBm
IC501, C184, 
Q161, D141
, C187
(J)*
Transmitted Power 
Confirmation
-
ANTI_TP
Remove the Antenna before starting step from 1 to 7.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: FP
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• PMID: 00000
• RF LEVEL = -70 dBm.
2. Execute the command ”sendchar TST”.
3. Execute the command “sendchar dmv 2 2”.
4. Check that “Signalling Status” has been set to “Locked”, then press “ACCEPT
RFPI”.
5. Initiate connection from Dect tester (“set up connect”)
6. Execute the command “ANT1”.
7. Confirm that the NTP value at ANT is 19.0 dBm ~ 25.0 dBm.
IC501, C803, 
C851, C853,  
DA802, Q302, 
C312, R312 
(K)* Modulation Check and 
Adjustment
-
ANTI_TP
Follow steps 1 to 6 of (J).
7.Confirm that the B-Field Modulation is -350 ± 50/+350 ± 50 kHz/div using data
type Fig31.
Refer to (J)
(L)* Frequency Offset Check
-
ANTI_TP
Follow steps 1 to 6 of (J).
7.Confirm that the frequency offset is < ± 20 kHz.
Refer to (J) 
(M)*
Sensitivity Receiver 
Confirmation
-
ANTI_TP
Follow steps 1 to 6 of (J).
7.Set DECT tester power to -88 dBm.
8.Confirm that the BER is < 1000 ppm.
Refer to (J) 
(N)*
Power RAMP 
Confirmation
-
Follow steps 1 to 6 of (J).
7.Confirm that Power RAMP is matching.
Refer to (J) 
(O)
Audio Check
-
1. Link with Handset which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 50 mA.
3. Input -45 dBm (600 
)/1 kHz to MIC of Handset. Measure the Level at Line I/F
and distortion level.
4. Confirm that the level is -1.5 dBm and that the distortion level is <5% at TEL
Line (600 
 Load).
5. Input -20 dBm (600 
)/1kHz to Line I/F. Measure the Level at Receiver of
Handset and distortion level (Receive volume set to second position from
minimum).
6. Confirm that the level is -31.0 ± 4 dBm and that the distortion level is <5 % at
Receiver (34 
 Load).
IC501, SA101, 
P101, D101, 
Q141, Q142, 
R141, R142, 
R144, R145, 
D141, Q161, 
R163, R164, 
C171, C173, 
R178, C184, 
C187 
(P)
Charging Check
-
1. Connect Charge Contact 12 
/2 W resistor between charge+ and charge-.
2. Measure and confirm voltage across the resistor is 3.6 V ± 0.4 V.
R371, R372, 
D362, C351
(Q)
TAM Operation 
Confirmation
(for KX-PRS120 only)
-
1. TAM Confirmation (Execute the command "sendchar VPI").
2. Confirm the returned Value (Value is "DD37RN 01").
IC501, IC601, 
R601, RA601, 
C601
(R)
2.4V Supply 
Confirmation VDD2 
VDD2
1. Confirm that the voltage between test point VDD2 and GND is 2.5V ± 0.2V.
IC501, Q302, 
C312, R312
Items
Check 
Point
Procedure
Check or 
Replace Parts
Page of 83