DOWNLOAD Panasonic KX-TG2511RUM / KX-TG2511RUN / KX-TG2511RUS / KX-TG2511RUT / KX-TG2512RUN / KX-TG2512RUS / KX-TG2521RUT / KX-TGA250RUM / KX-TGA250RUN / KX-TGA250RUS / KX-TGA250RUT Service Manual ↓ Size: 3.56 MB | Pages: 83 in PDF or view online for FREE

Model
KX-TG2511RUM KX-TG2511RUN KX-TG2511RUS KX-TG2511RUT KX-TG2512RUN KX-TG2512RUS KX-TG2521RUT KX-TGA250RUM KX-TGA250RUN KX-TGA250RUS KX-TGA250RUT
Pages
83
Size
3.56 MB
Type
PDF
Document
Service Manual / Supplement
Brand
Device
Provideo / DIGITAL CORDLESS ANSWERING SYSTEM
File
kx-tg2511rum-kx-tg2511run-kx-tg2511rus-kx-tg2511ru.pdf
Date

Panasonic KX-TG2511RUM / KX-TG2511RUN / KX-TG2511RUS / KX-TG2511RUT / KX-TG2512RUN / KX-TG2512RUS / KX-TG2521RUT / KX-TGA250RUM / KX-TGA250RUN / KX-TGA250RUS / KX-TGA250RUT Service Manual / Supplement ▷ View online

57
KX-TG2511RUM/KX-TG2511RUN//KX-TG2511RUS/KX-TG2511RUT/KX-TG2512RUN/KX-TG2512RUS/KX-TG2521RUT/KX-TGA250RUM/KX-TGA250RUN/KX-TGA250RUS/KX-TGA250RUT
12.7.1.2. Handset
[Changed from original section “11.7.1.2. Handset”]
First, operate the PC setting according to The Setting Method of JIG (Handset)(P.53).
Then download the appropriate data according to the following procedures.
Note:
(*3)  W: country code, XXX: revision number
“XXX” vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting Method of
JIG (Handset)
 (P.53).
(*4) Refer to Check Point (Handset) (P.41)
Items
How to download/Required adjustment
EEPROM (IC3)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Change the address “0001” of EEPROM to “00” to download 
the data.
2) Default batch file: Execute the command “default.bat”.
3) Default batch file (remaining): Execute the command 
“TGA255RU_DEF_RevXXX.bat”. (*3)
4) Country version batch file: Execute the command 
“TGA255RU_W_RevXXX.bat”. (*3)
5) Clock adjustment: Refer to Check Point (H). (*4)
6) 1.8 V setting and battery low detection: Refer to Check Point 
(A), (F) and (G). (*4)
X'tal (X1)
System clock
Clock adjustment data is in EEPROM, adjust the data again
after replacing it.
1) Refer to Check Point (C). (*4)
58
KX-TG2511RUM/KX-TG2511RUN//KX-TG2511RUS/KX-TG2511RUT/KX-TG2512RUN/KX-TG2512RUS/KX-TG2521RUT/KX-TGA250RUM/KX-TGA250RUN/KX-TGA250RUS/KX-TGA250RUT
12.8. RF Specification
12.8.1.
Base Unit
*: Refer to Check Point (Base Unit) (P.39)
12.8.2.
Handset
**: Refer to Check Point (Handset) (P.41)
Item
Value
Refer to -. *
TX Power
19 ~ 24 dBm
Check Point (Base Unit) (H)
Modulation
-350 ± 50/+350 ± 50 kHz/div
Check Point (Base Unit) (I)
Frequency Offset
±20 kHz
Check Point (Base Unit) (J)
RX Sensitivity
< 1000 ppm
Check Point (Base Unit) (K)
Power RAMP
Power RAMP is matching
Check Point (Base Unit) (L)
Item
Value
Refer to -. **
TX Power
19 ~ 24 dBm
Check Point (Handset) (I)
Modulation
-350 ± 50/+350 ± 50 kHz/div 
Check Point (Handset) (J)
Frequency Offset
±20 kHz
Check Point (Handset) (K)
RX Sensitivity
< 1000 ppm
Check Point (Handset) (L)
Power RAMP
Power RAMP is matching
Check Point (Handset) (M)
59
KX-TG2511RUM/KX-TG2511RUN//KX-TG2511RUS/KX-TG2511RUT/KX-TG2512RUN/KX-TG2512RUS/KX-TG2521RUT/KX-TGA250RUM/KX-TGA250RUN/KX-TGA250RUS/KX-TGA250RUT
12.9. How to Check the Handset Speaker or Receiver
1. Prepare the digital voltmeter, and set the selector knob to ohm meter.
2. Put the probes at the speaker terminals as shown below.
12.10. Frequency Table (MHz)
Note:
Channel No. 10: In the Test Mode on Base Unit and Handset.
BASE UNIT
HANDSET
Channel No
Transmit Frequency
Receive Frequency
Transmit Frequency
Receive Frequency
1
1897.344 1897.344 1897.344 1897.344 
2
1895.616 1895.616 1895.616 1895.616 
3
1893.888 1893.888 1893.888 1893.888 
4
1892.160 1892.160 1892.160 1892.160 
5
1890.432 1890.432 1890.432 1890.432 
6
1888.704 1888.704 1888.704 1888.704 
7
1886.976 1886.976 1886.976 1886.976 
8
1885.248
1885.248
1885.248
1885.248
9
1883.520 1883.520 1883.520 1883.520 
10
1881.792 1881.792 1881.792 1881.792 
Handset speaker (receiver)
Digital Voltmeter
Is the value between
(+) terminal and (–) terminal about 34 
Ω?
RECEIVER:
Is the value between
(+) terminal and (–) terminal about 8 
Ω?
NG
NO
OK
YES
Replace the speaker 
(receiver).
SPEAKER:
60
KX-TG2511RUM/KX-TG2511RUN//KX-TG2511RUS/KX-TG2511RUT/KX-TG2512RUN/KX-TG2512RUS/KX-TG2521RUT/KX-TGA250RUM/KX-TGA250RUN/KX-TGA250RUS/KX-TGA250RUT
13 Miscellaneous
13.1. How to Replace the Flat Package IC
Even if you do not have the special tools (for example, a spot heater) to remove the Flat IC, with some solder (large amount), a
soldering iron and a cutter knife, you can easily remove the ICs that have more than 100 pins.
13.1.1.
Preparation
• PbF (: Pb free) Solder
• Soldering Iron
Tip Temperature of 700 
F ± 20 F (370 C ± 10 C)
Note: We recommend a 30 to 40 Watt soldering iron. An expert may be able to use a 60 to 80 Watt iron where someone with
less experience could overheat and damage the PCB foil.
• Flux
Recommended Flux: Specific Gravity 
 0.82.
Type 
 RMA (lower residue, non-cleaning type)
Note: See About Lead Free Solder (Pbf: Pb free) (P.5)
13.1.2.
How to Remove the IC
1. Put plenty of solder on the IC pins so that the pins can be completely covered.
Note:
If the IC pins are not soldered enough, you may give pressure to the P.C. board when cutting the pins with a cutter.
2. Make a few cuts into the joint (between the IC and its pins) first and then cut off the pins thoroughly.
3. While the solder melts, remove it together with the IC pins.
When you attach a new IC to the board, remove all solder left on the board with some tools like a soldering wire. If some solder is
left at the joint on the board, the new IC will not be attached properly.
Page of 83
Display