Panasonic KX-TG2511RUM / KX-TG2511RUN / KX-TG2511RUS / KX-TG2511RUT / KX-TG2512RUN / KX-TG2512RUS / KX-TG2521RUT / KX-TGA250RUM / KX-TGA250RUN / KX-TGA250RUS / KX-TGA250RUT Service Manual / Supplement ▷ View online
49
KX-TG2511RUM/KX-TG2511RUN//KX-TG2511RUS/KX-TG2511RUT/KX-TG2512RUN/KX-TG2512RUS/KX-TG2521RUT/KX-TGA250RUM/KX-TGA250RUN/KX-TGA250RUS/KX-TGA250RUT
12 Measurements and Adjustments
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in
Troubleshooting Guide (P.28)
Troubleshooting Guide (P.28)
12.1. Equipment Required
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
Hewlett Packard, 53131A is recommended.
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
This equipment may be useful in order to precisely adjust like a mass production.
12.2. The Setting Method of JIG (Base Unit)
This section explains the PC setting to use command required in Check Point (Base Unit) (P.39).
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PNZZTG2521RU
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PNZZTG2521RU
Note:
*: If you have the JIG Cable for TCD500 series (PQZZ1CD505E), change the following values of resistance. Then you can use
it as a JIG Cable for both TCD300 and TCD500 series. (It is an upper compatible JIG Cable.)
it as a JIG Cable for both TCD300 and TCD500 series. (It is an upper compatible JIG Cable.)
12.2.1.
Connections
Connect the AC adaptor to DC-JACK (base unit).
Connect the JIG Cable GND (black) to GND.
Connect the JIG Cable RX (red) to URX and TX (yellow) to UTX.
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
) New value (k)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
Base unit P. C. board
UTX (yellow)
AC adaptor
1
2
3
3
GND (black)
URX (red)
GND
UTX
URX
To Serial Port
(COM port 1*)
(COM port 1*)
PC
50
KX-TG2511RUM/KX-TG2511RUN//KX-TG2511RUS/KX-TG2511RUT/KX-TG2512RUN/KX-TG2512RUS/KX-TG2521RUT/KX-TGA250RUM/KX-TGA250RUN/KX-TGA250RUS/KX-TGA250RUT
12.2.2.
How to install Batch file into P.C.
Note:
• “*****” varies depending on the country or models.
12.2.3.
Commands
See the table below for frequently used commands.
Command name
Function
Example
rdeeprom
Read the data of EEPROM
Type “rdeeprom 00 00 FF”, and the data from address
“00 00” to “FF” is read out.
“00 00” to “FF” is read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E
98” is written.
98” is written.
hookoff
Off-hook mode on Base
Type “hookoff”.
hookon
On-hook mode on Base
Type “hookon”.
getchk
Read checksum
Type “getchk”.
wreeprom
Write the data of EEPROM
Type “wreeprom 01 23 45”. “01 23” is address and “45”
is data to be written.
is data to be written.
1.
Insert the Batch file CD-ROM into CD-ROM drive and
copy PNZZTG**** folder to your PC (example: D drive).
2.
Open an MS-DOS mode window.
3.
At the DOS prompt, type "D:" (for example) to select the
drive, then press the Enter key.
4.
Type "CD
㪳PNZZTG****", then press the Enter key.
5.
Type "SET_COM=X", then press the Enter key
(X: COM port number used for the serial connection on your PC).
6.
Type "READID", then press the Enter key.
䊶If any error messages appear, change the port number or
䇭check the cable connection.
䊶If any value appear, go to next step.
7.
Type "DOSKEY", then press the Enter key.
<Example>
C:
>Documents and Settings>D:
D:
>>CD >PNZZTG****
D:
>PNZZTG**** >SET_COM=X
D:
>PNZZTG****>READID
00 52 4F A8 A8
D:
D:
>PNZZTG****>DOSKEY
D:
>PNZZTG****>
<Example: error happens>
C:
>Documents and Settings>D:
D:
>>CD >PNZZTG****
D:
>PNZZTG**** >SET_COM=X
D:
>PNZZTG****>READID
ޓCreateFile error
ERROR 10: Can't open serial port
D:
ERROR 10: Can't open serial port
D:
>PNZZTG ****>
<Example for Windows>
On your computer, click [Start], select Programs
(All Programs for Windows XP/Windows Server 2003),
then click
MS-DOS Prompt. (for Windows 95/Windows 98)
Or
Accessories-MS-DOS Prompt. (for Windows Me)
Or
Command Prompt. (for Windows NT 4.0)
Or
Accessories-Command Prompt.
(for Windows 2000/Windows XP/Windows Server 2003)
(All Programs for Windows XP/Windows Server 2003),
then click
MS-DOS Prompt. (for Windows 95/Windows 98)
Or
Accessories-MS-DOS Prompt. (for Windows Me)
Or
Command Prompt. (for Windows NT 4.0)
Or
Accessories-Command Prompt.
(for Windows 2000/Windows XP/Windows Server 2003)
51
KX-TG2511RUM/KX-TG2511RUN//KX-TG2511RUS/KX-TG2511RUT/KX-TG2512RUN/KX-TG2512RUS/KX-TG2521RUT/KX-TGA250RUM/KX-TGA250RUN/KX-TGA250RUS/KX-TGA250RUT
12.3. Adjustment Standard (Base Unit)
When connecting the simulator equipment for checking, please refer to below.
12.3.1.
Bottom View
Note:
(A) - (O) is referred to Check Point (Base Unit) (P.39)
VREF
C521
C120
D133
RA505
RTCK
R331
D132
C124
Q111
C601
C123
TM
S
TCK
VDDC
+3.0V
R601
RA151
TDO
VCCA
S
TM/CKM/P15
D113
R332
C331
R114
TDI
R
S
TN
C611
IC601
C185
R702
IC611
Q702
Q701
R373
R374
R701
D361
C361
D153
R111
R112
C111
C114
C121
C122
R121
R122
C112
R115
R116
R117
R118
C115
C116
R113
C110
C113
Q302
R306
VBAT
D301
+6.5V
URX
UTX
GND
R101
R102
R504 R503
R506
DCP
CHARGE-
F301
CHARGE+
DCM
L1R
L1T
LINE_DC
HAK_CL1
GAP1
Q140
R148 R149
ANT1
C103
C104
C302
C312
DC_IN
TP10
PNLB1214Z*
B
CTS60
CKM(G)
VBAT(A)
+3.0V(B)
DECT Tester
(H)(I)(J)(K)
52
KX-TG2511RUM/KX-TG2511RUN//KX-TG2511RUS/KX-TG2511RUT/KX-TG2512RUN/KX-TG2512RUS/KX-TG2521RUT/KX-TGA250RUM/KX-TGA250RUN/KX-TGA250RUS/KX-TGA250RUT
12.4. Adjustment Standard (Charger Unit)
When connecting the simulator equipment for checking, please refer to below.
12.4.1.
Bottom View
Note:
(A) is referred to Check Point (Charger Unit) (P.40)
Charge-
Charge+
12 /2 W
12 /2 W
Digital
Digital
V
Volt Meter
DC POWER
DC POWER
DC 6.5 V
(A)
(A)
TP4
TP3
1
2
J1
A
F1
PbF
PNLP1029YA
PQUP11532Y
TP3T
P
3
TP4(GND)T
P
4
(G
N
D
)
Click on the first or last page to see other KX-TG2511RUM / KX-TG2511RUN / KX-TG2511RUS / KX-TG2511RUT / KX-TG2512RUN / KX-TG2512RUS / KX-TG2521RUT / KX-TGA250RUM / KX-TGA250RUN / KX-TGA250RUS / KX-TGA250RUT service manuals if exist.