Panasonic AW-E600E Service Manual ▷ View online

2
Pin No.
Signal
Pin No.
Signal
1
Return Control
7
Iris Follow
2
Not Used
8
Auto/Remote Control
3
GND
9
Not Used
4
Auto/Manual Control
10
Not Used
5
Iris Control
11
Not Used
6
Lens Power
12
Not Used
<Front View>
Iris Connector (IRIS)
o q
i
w
u
e
y
t
r
!2
!0
!1
10. I/F Remote Connector (I/F REMOTE)
Input terminal dedicated to control signals from the
optional Remote Control Box (RCB) (WV-CB700A) and
the RCU (WV-RC700A, WV-RC550) and the camera
pan/tilt unit (AW-PH300).
* WV-CB700A is connected through the optional RCB
cable (AW-CA50T10).
* WV-RC700A/WV-RC550 is connected through the
optional RCU cable (AW-CA50A26).
* AW-PH300 is connected through the optional pan/ tilt
unit cable (AW-CA50T15).
11. Power Indicator
Red LED lamp lights to indicate that the specified DC
power is supplied to the camera.
7. NO/BAR Switch (NO/BAR/
)
The item just below can be selected by pressing this
switch while the Main Menu is on the screen.
While the Sub Menu is displayed any setting can be
brought down to a lower value with this switch.  When
the menu is not displayed or the camera is in shooting
mode, the colour bar and the shooting conditions are
alternately indicated by pressing the switch.
8. Video Output Connector (VIDEO OUT)
A composite video signal is provided at this connector.
9. Iris Connector (IRIS)
Input terminal for lens with an iris control function.
13. Cable Clamp
Clamp the DC Power Supply Cable (AW-CA4T1) con-
nected to the DC 12 V Input Connector to prevent it from
slipping out.
14. G/L Input Connector (G/L IN)
Signals synchronized with the reference signal are to be
supplied to this connector when the camera is to be syn-
chronized with the reference signal BBS.
15. Optional Card Slot
Slot for inserting an optional card.  For details, refer to
the manual for optional cards.
12. DC 12 V Input Connector (DC 12V IN)
12 V DC is supplied through the optional DC power sup-
ply cable (AW-CA4T1).
3
1. Test Equipment Required
8
The following test Equipments are required for
adjustment of the Convertible Camera AW-E600E.
8
Oscilloscope
8
Frequency Counter
8
Digital Voltmeter
8
Vectorscope
8
Waveform Monitor
8
Underscanned Colour Video Monitor
8
Signal Generator
8
12 V DC Power Supply Unit
8
Lux Meter
8
Lighting (200 footcandles (2,000 lx), Colour Temperature
3,200 K)
8
Auto Iris Lens (1/2" Bayonet-Mount)
8
Camera Cables AW-CA50T6
8
Remote Control Box (WV-CB700A)
8
1/2 ND Filter (2 pieces)
8
RCB Cable (AW-CA50T10)
8
Logarithmic Gray Scale Chart (Part No. : YWV2310RB99)
8
Extension Board between Joint Board and Preprocess or
DSP/Encoder Board (Part No. : 0E1A020A)
8
Extension Board between Power Board and Option Card
(Part No. : 0E1A021A)
8
Extension Board between Joint Board and Preamp. Board
(Part No. : 0E1A036A)
8
Extension Board between Joint Board and Drive Board
(Part No. : 0E1A037A)
ADJUSTMENT PROCEDURE
8
Extension Board between CCD and Preamp. Board (Part
No. : 0E1A038A)
8
Extension Board between CCD and Drive Board (Part No.
: 0E1A039A)
8
Extension Board between Joint Board and Preamp.
Board (Part No. : 0E1A040A)
8
Manual Adjustment Card (Part No. : 0E1A022A)
2. Disassembling Procedure for
Adjustment
8
Referring to Fig. 2-1, remove four screws that secure the
Rear Panel and remove the Rear Panel.
Fig. 2-1
Remove four screws.
Rear Panel
R
G
B
SIGNAL GND
VIDEO OUT
VIDEO GND
GND
28MHz
28MHZ GND
VD
HD
15.5V
12V (UNREG)
R  PEDE
SW    VR
SW    VR
SW    VR
SW    VR
SW    VR
SW    VR
SW    VR
SW    VR
SW    VR
WRITE SW
WIDE TELE
NEAR FAR
ZOOM SW GAIN SW
IRIS  VR
LENS CN
IRIS CONT SW
FOCUS SW
R  GAIN
R  PULCAN
G  PEDE
G  GAIN
G  PULCAN
B  PEDE
B  GAIN
B  PULCAN
7V
3V
2.5V
0.5V
–5V
–9V
GND
CAMERA  SIDE
4
3. Connection and Setting Up for
Adjustment
3.1. Connection
8
The Fig. 3-1 shows the connection diagram for the
adjustment procedure.
Fig. 3-1
8
Connect the Underscanned Colour Video Monitor to the
Video Output Connector on the Rear Panel of the
Convertible Camera AW-E600E through the Waveform
Monitor and the Vectorscope.
8
Terminate the input terminal of the Underscanned Colour
Video Monitor with 75 
.
8
Mount the Auto Iris Lens to the AW-E600E.
8
Connect the Power Supply Unit to the DC 12 V Input
Connector on the Rear Panel of the AW-E600E.
8
For the Optional Card AW-PB301 and AW-PB302,
connect the AW-CA50T6 to the I/F Remote Connector on
the Rear Panel of the AW-E600E.
8
Terminate the Connectors of the AW-CA50T6 with 75 
.
8
Connect the probe of the Digital Voltmeter, Oscilloscope
or Frequency Counter at the desired Test Point in each
adjustment step.
3.2. Setting Up for Standard Picture
8
The adjustment should be done after 10 minutes warm-up.
8
Set the Logarithmic Gray Scale Chart.
8
Incident light of 2,000 ± 50 lx on the Logarithmic Gray
Scale Chart.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Set the Camera so that the Logarithmic Gray Scale Chart
becomes full picture on the Underscanned Colour Video
Monitor.
8
Connect the Oscilloscope to E301 (G-IN) on the Preamp.
Board.
8
Adjust  the Lens Focus to obtain correct focal point.
Waveform
Monitor
Vectorscope
Underscanned
Colour  Video
Monitor
75
 Ω
AW-E600E
Signal Generator
Lens
Test Chart
Lcm
12V DC Power Supply
AW-CA50T6
I/F Remote
Video Out
G/L In
8
Set the Lens Iris so that the peak level of the Gray Scale
from the Blanking level becomes 200 mVp-p as shown in
Fig. 3-2.
Fig. 3-2
8
The adjustments should be done with this Standard
Picture, unless otherwise specified.
4. Adjustment Procedure
8
Refer to the Location of the Test Points and
Adjusting Controls on the page 8.
(1). Internal Frequency Adjustment
Test Point:
TP2 (INT 8FSC)
DSP/Encoder Board
Adjust:
R283 (INT 8FSC)
DSP/Encoder Board
8
Connect the Frequency Counter to TP2.
8
Adjust R283 so that Internal Frequency becomes 28.375
MHz ± 10 Hz.
(2). Preamp. DC Voltage Adjustment
Test Point:
E301 (G-IN)
Preamp. Board
E303 (G)
Preamp. Board
E103 (B)
Preamp. Board
E503 (R)
Preamp. Board
Adjust:
R327 (G-DC1)
Preamp. Board
R127 (R-DC1)
Preamp. Board
R527 (B-DC1)
Preamp. Board
8
Connect the Oscilloscope to E301.
8
Adjust  the Lens Focus to obtain correct focal point.
8
Set the Lens Iris so that the peak level of the Gray Scale
from the Blanking level becomes 200 mVp-p as shown in
Fig. 4-1.
8
Change the connection of  the Oscilloscope to E303.
8
Adjust R327 so that the DC Voltage at E303 becomes 1.3
V DC as shown in Fig. 4-1.
8
Change the connection of  the Oscilloscope to E103.
8
Adjust R127 so that the DC Voltage at E103 becomes 1.3
V DC as shown in Fig. 4-1.
8
Change the connection of  the Oscilloscope to E503.
200 mVp-p
5
8
Adjust R527 so that the DC Voltage at E503 becomes 1.3
V DC as shown in Fig. 4-1.
Fig. 4-1
(3). Preamp. Output Gain Adjustment
Test Point:
E301 (G-IN)
Preamp. Board
E201 (G-IN)
Preprocess Board
E301 (B-IN)
Preprocess Board
E101 (R-IN)
Preprocess Board
Adjust:
R355 (G-GAIN)
Preamp. Board
R363 (G-DC2)
Preamp. Board
R155 (B-GAIN)
Preamp. Board
R163 (B-DC2)
Preamp. Board
R555 (R-GAIN)
Preamp. Board
R563 (R-DC2)
Preamp. Board
8
Connect the Oscilloscope to E301 on the Preamp. Board.
8
Adjust  the Lens Focus to obtain correct focal point.
8
Set the Lens Iris so that the peak level of the Gray Scale
from the Blanking level becomes 200 mVp-p as shown in
Fig. 4-2.
Fig. 4-2
8
Change the connection of the Oscilloscope to E201 on the
Preprocess Board.
8
Adjust R355 so that the Gch Signal level at E201
becomes  300 mV as shown in Fig 4-3.
8
Set the Oscilloscope to the DC mode.
8
Adjust R363 so that the Gch DC Voltage at E201
becomes  100 mV DC as shown in Fig 4-3.
Fig. 4-3
8
Change the connection of the Oscilloscope to E301 on the
Preprocess Board.
8
Adjust R155 so that the Bch Signal level at E301 becomes
300 mV as shown in Fig 4-4.
8
Set the Oscilloscope to the DC mode.
8
Adjust R163 so that the Bch DC Voltage at E301 becomes
300 mV DC as shown in Fig 4-4.
Fig. 4-4
8
Change the connection of the Oscilloscope to E101 on the
Preprocess Board.
8
Adjust R555 so that the Rch Signal level at E101 becomes
300 mV as shown in Fig 4-3.
8
Set the Oscilloscope to the DC mode.
8
Adjust R563 so that the Rch DC Voltage at E101 becomes
100 mV DC as shown in Fig 4-3.
(4). White Clip Adjustment
Test Point:
E101 (R-IN)
Preprocess Board
E201 (G-IN)
Preprocess Board
E301 (B-IN)
Preprocess Board
Adjust:
R701 (G-WCLP)
Preamp.-Sub Board
R705 (R-WCLP)
Preamp.-Sub Board
R707 (B-WCLP)
Preamp.-Sub Board
8
Observe at E101, E201 and E301 by the Oscilloscope.
8
Turn R701, R705 and R707 so that the signals are not
clipped.
8
Aim the Logarithmic Gray Scale Chart.
8
Set the Lens Iris by two digit to open direction.
8
Connect CH1 of the Oscilloscope to E201 and CH2 of the
Oscilloscope to E101.
Ground
Level
1.3 V DC
200 mVp-p
300 mVp-p
100 mV DC
300 mVp-p
300 mV DC
Page of 44
Display