Panasonic AG-HVX200P / AG-HVX200AN / AG-HVX200E / AG-HVX200MC / AG-HVX202EN Service Manual ▷ View online
INF-11
7-2. Operation flow chart after board exchanged
7-2-1. CAMERA Board
CAMERA Adjustment is required.
Regarding required adjustment items, refer to item “7-3. Adjustment after replacement of major
Parts”.
Regarding required adjustment items, refer to item “7-3. Adjustment after replacement of major
Parts”.
NO
CAMERA Board is exchanged.
Overall check
YES
Confirm that the software version.
●CAM MICON
●CAM FPGA
●CAM EEPROM
(Refer to Global Service WEB Site
about number of latest version.)
●CAM MICON
●CAM FPGA
●CAM EEPROM
(Refer to Global Service WEB Site
about number of latest version.)
(Confirmation method
Page INF-20)
Page INF-20)
( Page INF-16)
*The CAM MICON and CAM FPGA
software do not required update.
Regarding EEPROM updata procedure,
refer to item “14. EEPROM data update
procedure” in this section. ( Page INF-49)
software do not required update.
Regarding EEPROM updata procedure,
refer to item “14. EEPROM data update
procedure” in this section. ( Page INF-49)
INF-12
7-2-2. VTR Board
VTR Adjustment is required.
Regarding required adjustment items, refer to item “7-3. Adjustment after
replacement of major Parts”.
Regarding required adjustment items, refer to item “7-3. Adjustment after
replacement of major Parts”.
Is it possible to backup the
data of VCR EEPROM?
data of VCR EEPROM?
Backup the EEPROM data
NO
YES
YES
NO
NO
YES
*The VCR MICON and VCR DUO
software do not required update.
Regarding EEPROM updata procedure,
refer to item “14. EEPROM data update
procedure” in this section.
software do not required update.
Regarding EEPROM updata procedure,
refer to item “14. EEPROM data update
procedure” in this section.
VTR Board is exchanged.
Exchange the VTR Board and load
the back up data to new board.
the back up data to new board.
Confirm that the software version.
●VCR MICON ●VCR DUO
●VCR EEPROM
(Refer to Global Service WEB Site
about number of latest version.)
●VCR MICON ●VCR DUO
●VCR EEPROM
(Refer to Global Service WEB Site
about number of latest version.)
Overall check
Confirm that the software version.
●VCR MICON ●VCR DUO
●VCR EEPROM
(Refer to Global Service WEB Site
about number of latest version.)
●VCR MICON ●VCR DUO
●VCR EEPROM
(Refer to Global Service WEB Site
about number of latest version.)
Hour meter is becomes to “0”.
Write the 1394 UID(TAPE) numbers.
If the numbers are missed, So please contact the
Panasonic Service Engineering.
Regarding UID writing procedure, refer to item “15. UID Writing procedure”.
If the numbers are missed, So please contact the
Panasonic Service Engineering.
Regarding UID writing procedure, refer to item “15. UID Writing procedure”.
(EEPROM data save and writing procedure
Page INF-42)
Page INF-42)
(Confirmation method
Page INF-20)
Page INF-20)
(Confirmation method
Page INF-20)
Page INF-20)
( Page INF-53)
( Page INF-16)
( Page INF-49)
INF-13
7-2-3. CODEC Board
Is it possible to backup the data
of CODEC EEPROM?
of CODEC EEPROM?
Backup the EEPROM data
NO
YES
YES
NO
NO
YES
CODEC Board is exchanged.
Exchange the CODEC Board and load
the back up data to new board.
the back up data to new board.
Overall check
Write the Serial Number
With Serial Number Writing Procedure, contact Panasonic Service Engineering.
With Serial Number Writing Procedure, contact Panasonic Service Engineering.
(EEPROM data save and writing procedure
Page INF-42)
Page INF-42)
Confirm that the software version.
●SYS MICON ●P2CS OS
●P2CS AP ●SYS FPGA
●SYS EEPROM
(Refer to Global Service WEB Site
about number of latest version.)
●SYS MICON ●P2CS OS
●P2CS AP ●SYS FPGA
●SYS EEPROM
(Refer to Global Service WEB Site
about number of latest version.)
(Confirmation method:
NOTE
Page INF-20)
Rewriting setting of data according to destination
(It required E and MC model only).
Refer to item “16. Rewriting setting of data according to destination”.
(It required E and MC model only).
Refer to item “16. Rewriting setting of data according to destination”.
Write the 1394 UID(P2 & SBP2) numbers.
If the numbers are missed, so please contact the Panasonic Service Engineering.
Regarding UID writing procedure, refer to item “15. UID Writing procedure”.
If the numbers are missed, so please contact the Panasonic Service Engineering.
Regarding UID writing procedure, refer to item “15. UID Writing procedure”.
The DATA initialization is executed.
Refer to item “9-5. DATA INIT.”.
Refer to item “9-5. DATA INIT.”.
Confirm that the software version.
●SYS MICON ●P2CS OS
●P2CS AP ●SYS FPGA
●SYS EEPROM
(Refer to Global Service WEB Site
about number of latest version.)
●SYS MICON ●P2CS OS
●P2CS AP ●SYS FPGA
●SYS EEPROM
(Refer to Global Service WEB Site
about number of latest version.)
(Confirmation method:
NOTE
Page INF-20)
( Page INF-27)
( Page INF-54)
( Page INF-53)
Update to latest version.
*The SYS FPGA software do not
required update.
Regarding software(firmware) updata
procedure, refer to item “10. Firmware
update procedure” in this section.
Regarding EEPROM updata procedure,
refer to item “14. EEPROM data update
procedure” in this section.
*The SYS FPGA software do not
required update.
Regarding software(firmware) updata
procedure, refer to item “10. Firmware
update procedure” in this section.
Regarding EEPROM updata procedure,
refer to item “14. EEPROM data update
procedure” in this section.
( Page INF-29)
( Page INF-49)
NOTE:
Regarding version confirmation about SYS
MICON and P2CS OS/AP, refer to item “10.
Firmware update procedure” in this
section.
Regarding version confirmation about SYS
MICON and P2CS OS/AP, refer to item “10.
Firmware update procedure” in this
section.
( Page INF-29)
INF-14
7-2-4. CAMERA LENS Ass`y
When LENS Ass`y, PRISM Ass`y and ZOOM MOTOR Ass`y are is exchanged, it requires same operation.
7-2-5. ZOOM SW Ass`y
When ZOOM SW board is exchanged, it requires same operation.
7-2-6. SIDE JACK1 Board
CAMERA LENS Ass`y is exchanged.
CAMERA Adjustment is required.
Regarding required adjustment items, refer to item
“7-3. Adjustment after replacement of major Parts”.
Regarding required adjustment items, refer to item
“7-3. Adjustment after replacement of major Parts”.
Overall check
ZOOM SW Ass`y is exchanged.
Overall check
SIDE JACK1 is exchanged.
Re-adjustment
OK
NG
Confirmation of CAMERA Adjustment is required.
Regarding required confirmation items, refer to item
“7-3. Adjustment after replacement of major Parts”.
Regarding required confirmation items, refer to item
“7-3. Adjustment after replacement of major Parts”.
Overall check
( Page INF-16)
CAMERA Adjustment is required.
Regarding required adjustment items, refer to item
“7-3. Adjustment after replacement of major Parts”.
Regarding required adjustment items, refer to item
“7-3. Adjustment after replacement of major Parts”.
( Page INF-16)
( Page INF-16)
Click on the first or last page to see other AG-HVX200P / AG-HVX200AN / AG-HVX200E / AG-HVX200MC / AG-HVX202EN service manuals if exist.