INF-11 
7-2. Operation flow chart after board exchanged
 
 
7-2-1. CAMERA Board
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CAMERA Adjustment is required. 
Regarding required adjustment items, refer to item “7-3. Adjustment after replacement of major
Parts”
NO 
CAMERA Board is exchanged. 
Overall check 
YES 
Confirm that the software version. 
CAM MICON 
CAM FPGA 
CAM EEPROM 
(Refer to Global Service WEB Site 
about number of latest version.) 
(Confirmation method 
     Page INF-20) 
(     Page INF-16) 
*The CAM MICON and CAM FPGA 
software do not required update. 
Regarding EEPROM updata procedure,
refer to item “14. EEPROM data update
procedure” 
in this section. (     Page INF-49) 
INF-12 
7-2-2. VTR Board
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
VTR Adjustment is required. 
Regarding required adjustment items, refer to item “7-3. Adjustment after
replacement of major Parts”
Is it possible to backup the 
data of VCR EEPROM? 
Backup the EEPROM data 
NO 
YES 
YES 
NO 
NO 
YES 
*The VCR MICON and VCR DUO 
software do not required update. 
Regarding EEPROM updata procedure, 
refer to item “14. EEPROM data update 
procedure” 
in this section. 
VTR Board is exchanged. 
Exchange the VTR Board and load 
the back up data to new board. 
Confirm that the software version. 
VCR MICON    VCR DUO 
VCR EEPROM 
(Refer to Global Service WEB Site
about number of latest version.) 
Overall check 
Confirm that the software version. 
VCR MICON    VCR DUO 
VCR EEPROM 
(Refer to Global Service WEB Site
about number of latest version.) 
Hour meter is becomes to “0”. 
Write the 1394 UID(TAPE) numbers. 
If the numbers are missed, So please contact the 
Panasonic Service Engineering. 
Regarding UID writing procedure, refer to item “15. UID Writing procedure”
(EEPROM data save and writing procedure 
     Page INF-42) 
(Confirmation method 
     Page INF-20) 
(Confirmation method 
     Page INF-20) 
(     Page INF-53) 
(     Page INF-16) 
(     Page INF-49) 
INF-13 
7-2-3. CODEC Board
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Is it possible to backup the data 
of CODEC EEPROM? 
Backup the EEPROM data 
NO 
YES 
YES 
NO 
NO 
YES 
CODEC Board is exchanged. 
Exchange the CODEC Board and load
the back up data to new board. 
Overall check 
Write the Serial Number 
With Serial Number Writing Procedure, contact Panasonic Service Engineering. 
(EEPROM data save and writing procedure 
     Page INF-42) 
Confirm that the software version. 
SYS MICON P2CS OS 
P2CS AP SYS FPGA 
SYS EEPROM 
(Refer to Global Service WEB Site 
about number of latest version.) 
(Confirmation method: 
NOTE
 
            Page INF-20) 
Rewriting setting of data according to destination 
(It required E and MC model only). 
Refer to item “16. Rewriting setting of data according to destination”. 
Write the 1394 UID(P2 & SBP2) numbers. 
If the numbers are missed, so please contact the Panasonic Service Engineering. 
Regarding UID writing procedure, refer to item “15. UID Writing procedure”
The DATA initialization is executed. 
Refer to item “9-5. DATA INIT.”. 
Confirm that the software version. 
SYS MICON P2CS OS 
P2CS AP SYS FPGA 
SYS EEPROM 
(Refer to Global Service WEB Site 
about number of latest version.) 
(Confirmation method: 
NOTE
 
            Page INF-20) 
(     Page INF-27) 
(     Page INF-54) 
(     Page INF-53) 
Update to latest version. 
*The SYS FPGA software do not 
required update. 
Regarding software(firmware) updata 
procedure, refer to item “10. Firmware 
update procedure” 
in this section. 
 
Regarding EEPROM updata procedure, 
refer to item “14. EEPROM data update 
procedure” 
in this section. 
 
(     Page INF-29) 
(     Page INF-49) 
NOTE: 
Regarding version confirmation about SYS 
MICON and P2CS OS/AP, refer to item “10. 
Firmware update procedure” in this 
section.
 
(     Page INF-29) 
INF-14 
7-2-4. CAMERA LENS Ass`y
 
 
When LENS Ass`y, PRISM Ass`y and ZOOM MOTOR Ass`y are is exchanged, it requires same operation. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
7-2-5. ZOOM SW Ass`y
 
 
When ZOOM SW board is exchanged, it requires same operation. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
7-2-6. SIDE JACK1 Board
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CAMERA LENS Ass`y is exchanged. 
CAMERA Adjustment is required. 
Regarding required adjustment items, refer to item 
“7-3. Adjustment after replacement of major Parts”
Overall check 
ZOOM SW Ass`y is exchanged. 
Overall check 
SIDE JACK1 is exchanged. 
Re-adjustment 
OK 
NG 
Confirmation of CAMERA Adjustment is required. 
Regarding required confirmation items, refer to item 
“7-3. Adjustment after replacement of major Parts”
Overall check 
(     Page INF-16) 
CAMERA Adjustment is required. 
Regarding required adjustment items, refer to item 
“7-3. Adjustment after replacement of major Parts”