DOWNLOAD Panasonic AG-DVX100BP / AG-DVX100E / AG-DVX100BE / AG-DVX100AN / AG-DVX102BEN / AG-DVC180BMC Service Manual ↓ Size: 45.97 MB | Pages: 127 in PDF or view online for FREE

Model
AG-DVX100BP AG-DVX100E AG-DVX100BE AG-DVX100AN AG-DVX102BEN AG-DVC180BMC
Pages
127
Size
45.97 MB
Type
PDF
Document
Service Manual
Brand
Device
Provideo / CAMERA RECORDER
File
ag-dvx100bp-ag-dvx100e-ag-dvx100be-ag-dvx100an-ag-.pdf
Date

Panasonic AG-DVX100BP / AG-DVX100E / AG-DVX100BE / AG-DVX100AN / AG-DVX102BEN / AG-DVC180BMC Service Manual ▷ View online

INF-13 
5-2-2. Other item.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5-3. ADJUST MENU (VCR mode) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOTE: Please do not change the setting of the items of “DEBUG DISP” and “DEBUG MODE”. These items 
are for factory use only. 
 
 
DIAGNOSTIC MENU 
 
BER DISPLAY                            OFF 
SAMPLE SPEED           SLOW 
DIF INFO                                      OFF 
CYLINDER                10000H 
TAPE RUN                10000H 
THREADING               10000T 
 
 
 
PUSH MENU TO EXIT 
These items are displayed even by the CAMERA
SERVICE menu. (refer to item 5-1-3 and 5-1-5. ) 
ADJUST MENU 
 
    ATF GAIN                              OFF 
    LINEARITY                            OFF 
AUDIO FILTER                      ON 
  Y LEVEL                 1B 
    C LEVEL                                  27 
    DEBUG DISP                        OFF 
    DEBUG MODE                      OFF 
    LCD OFFSET                        OFF 
     
 
PUSH MENU TO EXIT 
Setting item for LISTA Measurement 
These items are displayed even by 
the CAMERA SERVICE menu. 
(refer to item 5-1-1 and 5-1-4. ) 
ADJUST MENU 
 
    EVF OFFSET                          OFF 
     
 
     
     
     
     
     
     
 
PUSH MENU TO EXIT 
These items are displayed even by
the CAMERA SERVICE menu.
(refer to item 5-1-6. ) 
INF-14 
5-3-1. Setting item for LISTA Measurement 
 
ATF GAIN 
 
The speed of the tape changes if this item set to “ON” for the ATF sensitivity confirmation. 
After selected “ON”, By pressing SET(STILL) of OPERATION LEVER, enter the adjustment mode and then exit the 
menu once. The VTR mode is operated when the menu mode is exited temporarily. The screen below is displayed. 
NOW SERVO ADJUST 
 
PUSH MENU TO RETURN 
It will be returned to ADJUST MENU when the MENU button is pressed in this condition. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
LINEARITY 
 
The ATF sensitivity changes if this item set to “ON” for the LINEARITY confirmation. 
After selected “ON”, By pressing SET(STILL) of OPERATION LEVER, enter the adjustment mode and then exit the 
menu once. The VTR mode is operated when the menu mode is exited temporarily. The screen below is displayed. 
NOW SERVO ADJUST 
 
PUSH MENU TO RETURN 
It will be returned to ADJUST MENU when the MENU button is pressed in this condition. 
 
 
 
 
 
 
Press MENU button. 
After selected “ON”, By pressing SET(STILL) of OPERATION LEVER 
 
 
NOW SERVO ADJUST 
PUSH MENU TO RETURN 
 
 
(Adjustment mode screen) 
ADJUST MENU 
 
    ATF GAIN                                OFF 
    LINEARITY                              OFF 
AUDIO FILTER                        ON 
  Y LEVEL                  1B 
    C LEVEL                                    27 
    DEBUG DISP                          OFF 
    DEBUG MODE                        OFF 
    LCD OFFSET                          OFF 
     
 
PUSH MENU TO EXIT 
OFF 
ON 
INF-15 
6. EEPROM 
 
Several information are stored in EEPROM. Please refer to below explanation, which data stored in EEPROM. 
 
6-1. Each Menu Data
 
6-1-1. Setting menu data
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
n  : Each setting value are stored in VTR EEPROM. 
▲  : Each setting value are stored in CAMERA EEPROM. 
NOTE1: The item “PROGRESSIVE” and “NAME EDIT” in SCENE FILE screen, which is stored in VTR EEPROM. 
NOTE2:
 The item “Aspect CONV” in CAMERA SETUP screen, which is stored in VTR EEPROM. 
 
 
 
6-1-2. SERVICE menu data
 
 
Please refer to as follows. 
ITEM STORED 
IN 
DEFECT COMP 
AUDIO FILTER 
VTR EEPROM 
VTR SUB MICON 
VTR SUB MICON (IC3001) 
VTR MAIN MICON 
VTR MAIN MICON (IC2001) 
VTR EEPROM 
VTR EEPROM 
VTR EEPROM SUM 
VTR EEPROM 
CAM MICON 
CAM MICON (IC301) 
CAM EEPROM 
CAM EEPROM 
CYLINDER VTR 
EEPROM 
TAPE RUN 
VTR EEPROM 
THREADING VTR 
EEPROM 
Y LEVEL 
VTR EEPROM 
C LEVEL 
VTR EEPROM 
DIF INFO 
DEBUG DISP 
DEBUG MODE 
LCD OFFSET 
VTR EEPROM 
EVF OFFSET 
VTR EEPROM 
 
n
n
n
n
n
Common display items 




n
n
n
CAMERA MENU 
 
1. SCENE FILE 
2. CAMERA SETUP 
3. SW MODE 
4. AUTO SW 
5. RECORDING SETUP 
6. DISPLAY SETUP 
7. OTHER FUNCTIONS 
 
 
PUSH MENU TO EXIT 
VCR FUNCTIONS 
 
1. PLAYBACK FUNCTIONS 
2. RECORDING SETUP 
3. AV IN/OUT SETUP 
4. DISPLAY SETUP 
5. OTHER FUNCTIONS 
 
 
 
 
PUSH MENU TO EXIT 
INF-16 
6-1-3. DIAGNOSTIC menu data
 
 
Please refer to as follows. 
ITEM STORED 
IN 
BER DISPLAY 
SAMPLE SPEED 
DIF INFO 
CYLINDER VTR 
EEPROM 
TAPE RUN 
VTR EEPROM 
THREADING VTR 
EEPROM 
 
 
6-1-4. ADJUST menu data
 
 
Please refer to as follows. 
ITEM STORED 
IN 
ATF GAIN 
LINEARITY X 
AUDIO FILTER 
Y LEVEL 
VTR EEPROM 
C LEVEL 
VTR EEPROM 
DEBUG DISP 
DEBUG MODE 
LCD OFFSET 
VTR EEPROM 
EVF OFFSET 
VTR EEPROM 
 
 
6-1-5. The other data
 
 
Except setting menu data, below indicated information are stored in EEPROM. 
EEPROM INFORMATION 
REMARK 
CAMERA adjustment value 
Adjustment values are set by EVR software. 
CAMERA EEPROM 
Control data 
------------------ 
VTR adjustment Value 
Adjustment values are set by EVR software or 
SERVCE/ADJUST menu. 
HOUR METER 
------------------ 
Time code data 
------------------ 
VTR EEPROM 
Control data 
------------------ 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other AG-DVX100BP / AG-DVX100E / AG-DVX100BE / AG-DVX100AN / AG-DVX102BEN / AG-DVC180BMC service manuals if exist.