Panasonic AG-DVX100BP / AG-DVX100E / AG-DVX100BE / AG-DVX100AN / AG-DVX102BEN / AG-DVC180BMC Service Manual ▷ View online
INF-5
3. MANUAL TAPE EJECT (EMERGENCY EJECT)
When the tape cannot be ejected by normal operation because of trouble in the electrical system or mechanical
system, the tape can be removed from the unit manually by using the following method.
NOTE: By below indicated method, the unit will not take up tape slack. Be careful when removing the tape from
Cassette Holder.
1. Unscrew the screw (A) and open the cassette cover as shown in figure.
2. Supply 4.5 Volts using 3 AA batteries in series to unload the posts using the motor.
3. Stop supplying the power when the tape is ejected and remove the tape from Cassette Holder.
<How to rolls up tape>
Be sure to take up the tape slack so that tape does not become damaged.
1. Remove the Mechanism Unit.
2. Supply 4.5 Volts to unload the posts using the motor.
3. Stop supplying the power at unloading complete position.
NOTE: If power is supplied too long, then the Cassette tape will be ejected prematurely.
4. Turn the Gear of Supply Reel as shown in figure, and this will take up the slack in the tape.
5. Supply 4.5 Volts again to eject the tape using the motor and remove the tape from Cassette Holder.
(B)
(A)
LOADING MOTOR
UNLOADING ............ A: +4.5V B: GND
LOADING ................. A: GND B: +4.5V
LOADING ................. A: GND B: +4.5V
Turn this Gear with the tip of
a tweezers.
a tweezers.
(Bottom side of Mechanism)
SCREW (A)
INF-6
11
4. LITHIUM BATTERY
4-1. Replacement Procedure
1. There is a Lithium battery on the BACK CONNECT C.B.A.
2. Unsolder the Lithium battery and then replace with the new one. Please refer to item “16. Removal of BACK
2. Unsolder the Lithium battery and then replace with the new one. Please refer to item “16. Removal of BACK
CONNECT C.B.A.” in section 2(Disassembly Procedure) about how removal of BACK CONNECT C.B.A..
NOTE:
The lithium battery is a critical component.
It must never be subjected to excessive heat of discharge.
It must therefore only be fitted in equipment designed specifically for its use.
Replacement batteries must be of the same type and manufacture.
They must be fitted in the same manner and location as the original battery, with the correct polarity contacts
observed.
Do not attempt to re-charge the old battery or re-use it for any other purpose.
It should be disposed of in waste products destined for burial rather than incineration.
CAUTION
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the equipment manufacturer.
Discard used batteries according to manufacture’s instructions.
Replace only with the same or equivalent type recommended by the equipment manufacturer.
Discard used batteries according to manufacture’s instructions.
BACK CONNECT C.B.A.
LITHIUM BATTERY
IC2002<3>
(REAL TIME CLOCK)
(REAL TIME CLOCK)
RTC_3V
60B
60A
P2002 P53
BACK_CONNECT C.B.A.
VTR C.B.A.
(LI-BATT)
B51
INF-7
5. SERVICE MENU
The SERVICE(CAMERA mode), DIAGNOSTIC(VCR mode) and ADJUST(VCR mode) menu can be displayed as
follows.
Press the button in order of “ADUB button” → “STOP button” → “MODE CHK button” → “MENU button”,
SERVICE menu in CAMERA mode, DIAGNOSTIC and the ADJUST menu in VCR mode can be displayed in
addition to a setup menus.
Next, Tilt the OPERATION lever in the UP( ► :PLAY) or DOWN (
■
:STOP) direction, select the DIAGNOSTIC or
ADJUST menu, press SET(STILL) of the OPERATION lever to open the DIAGNOSTIC or ADJUST menu.
CAMERA MENU
1. SCENE FILE
2. CAMERA SETUP
3. SW MODE
4. AUTO SW
5. RECORDING SETUP
6. DISPLAY SETUP
7. OTHER FUNCTIONS
SERVICE MENU
PUSH MENU TO EXIT
VCR FUNCTIONS
1. PLAYBACK FUNCTIONS
2. RECORDING SETUP
3. AV IN/OUT SETUP
4. DISPLAY SETUP
5. OTHER FUNCTIONS
DIAGNOSTIC MENU
ADJUST MENU
ADJUST MENU
PUSH MENU TO EXIT
Press the button in order of “ADUB
button” → “STOP button” → “MODE
CHK button” → “MENU button”.
button” → “STOP button” → “MODE
CHK button” → “MENU button”.
Normal Screen
(CAMERA mode)
Normal Screen
(VCR mode)
INF-8
5-1. SERVICE MENU (CAMERA mode)
5-1-1. Audio Filter
AUDIO FILTER
ON: The mechanism noise cancellation function operates by IC3001(DUO).
OFF: The mechanism noise cancellation function does not operates by IC3001(DUO).
Factory default setting is “ON”.
SERVICE MENU
CYLINDER 10000H
TAPE RUN 10000H
THREADING 10000T
Y LEVEL 1B
C LEVEL 27
DIF INFO OFF
DEBUG DISP OFF
DEBUG MODE OFF
PUSH MENU TO RETURN
SERVICE MENU
LCD OFFSET OFF
EVF OFFSET OFF
PUSH MENU TO RETURN
NOTE: Please do not change the setting of the
items of “DEFFECT COMP”, “DEBUG
DISP” and “DEBUG MODE”. These items
are for factory use only.
Factory default setting is “OFF”.
DISP” and “DEBUG MODE”. These items
are for factory use only.
Factory default setting is “OFF”.
SERVICE MENU
DEFFECT COMP OFF
AUDIO FILTER ON
VTR SUB MICON 1.001
VTR MAIN MICON 1.77-P-F
VTR EEPRPM 0.007
VTR EEPROM SUM D7EF
CAM MICON 0.D0
CAM EEPROM 0.CA
PUSH MENU TO RETURN