Panasonic AG-DVX100BP / AG-DVX100E / AG-DVX100BE / AG-DVX100AN / AG-DVX102BEN / AG-DVC180BMC Service Manual ▷ View online

INF-9 
5-1-2. Software Version Display. 
 
This unit have three pieces of microprocessor and two pieces of EEPROM. 
 
--- 
CAMERA board 
VTR board 
Microprocessor 
IC301 
IC2001(VTR MAIN MICON) 
IC3001(VTR SUB MICON) 
EEPROM IC307 
IC2006 
--- 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5-1-3. Hour Meter Display. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
ITEM Display 
Data 
Description 
TAPE RUN 
00000H 
– 
99999H 
It displays the time that the tape is running in units of hours. 
THREADING 00000T 
 99999T 
It displays the number of times the tape is inserted. 
CYLINDER 00000H 
 99999H 
It displays the time that the cylinder is rotating in units of hours. 
It displays same time as in the item HOUR METER of OTHER 
FUNCTION menu. 
SERVICE MENU 
 
DEFFECT COMP          OFF 
AUDIO FILTER                        ON 
VTR SUB MICON         1.001 
VTR MAIN MICON       1.77-P-F 
VTR EEPRPM            0.007 
VTR EEPROM SUM       D7EF 
CAM MICON                            0.D0 
CAM EEPROM            0.CA 
 
 
PUSH MENU TO RETURN 
(In case of VTR MAIN MICON) 
*.** - P - F 
Version Number 
N = NTSC 
P = PAL 
F = FLASH 
M = MASK 
This indicates the 
value of the check sum 
value of the VTR 
EEPROM displayed in 
hexadecimal. 
The version of VTR, and the 
CAMERA microprocessor, 
VTR and CAMERA EEPROM 
are displayed. 
TAPE RUN, THREADING are 
displayed in addition to the rotating 
time of the Cylinder (CYLINDER). 
SERVICE MENU
 
 
CYLINDER               10000H 
TAPE RUN               10000H 
THREADING             10000T 
Y LEVEL                   1B 
C LEVEL                   27 
DIF INFO                                    OFF 
DEBUG DISP                            OFF 
DEBUG MODE                          OFF 
 
 
PUSH MENU TO RETURN 
CAMERA C.B.A.(Foil side) 
IC307 
IC301 
VTR C.B.A.(Foil side) 
IC2001 
IC2006 
IC3001 
INF-10 
5-1-4. Adjustment item for Video Level 
 
Y LEVEL 
Y level of VIDEO OUT and S-VIDEO OUTPUT signal can be adjusted on this item. 
The displayed value is the same as value for Luminance level adjustment in EVR adjustment. 
 
C LEVEL 
C level of VIDEO OUT and S-VIDEO OUTPUT signal can be adjusted on this item. 
The displayed value is the same as value for Chroma level adjustment in EVR adjustment. 
 
 
 
5-1-5. DIF Status Display.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NORMAL: The DIF STATUS display is updated every five frames. 
FAST: The DIF STATUS display is updated every frame. 
 
Factory default setting is “OFF”. 
 
 
Items Description 
Remark 
NODECNT 
Number of NODE connections. 
 
MY_ID 
NODE ID of this unit. 
 
ROOT_ID ROOT 
ID 
 
IRM_ID 
PHY ID of IRM 
IRM(Isochronous Resonance Manager) 
IN_CH 
Input channel number of Isochronous data. 
 
OUT_CH 
Output channel number of Isochronous data.
 
 
DIFMODE DIF 
mode 
 
RX_IN 
Received condition of Isochronous data.
 
 
O_BCC 
Transmitted condition of Isochronous data. 
 
STYPE 
Type of VIDEO signal 
 
FIELD NTSC/PAL 
 
SPEED 
Speed of Isochronous data. 
IN_SPD in VCR MODE 
UID 
USER ID of 1394 equipment 
 
AS 
Source pack of AUDIO 
 
ASC 
Source control pack of AUDIO
 
 
VS 
Source pack of VIDEO
 
 
VSC 
Source control pack of VIDEO
 
 
HEADER HEADER 
pack 
 
 
Set the item “DIF INFO” to NORMAL 
or FAST and it does ON/OFF of the 
DIF STATUS display by pressing the 
MODE CHECK button on normal 
screen. 
SERVICE MENU
 
 
CYLINDER               10000H 
TAPE RUN               10000H 
THREADING             10000T 
Y LEVEL                   1B 
C LEVEL                   27 
DIF INFO                                    OFF 
DEBUG DISP                            OFF 
DEBUG MODE                          OFF 
 
 
PUSH MENU TO RETURN 
OFF 
NORMAL 
FAST 
INF-11 
5-1-6. LCD/EVF Correction
 
 
LCD OFFSET 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
EVF OFFSET 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
R signal output to LCD is corrected. 
1: Correction level 1 
2: Correction level 2 
SERVICE MENU
 
 
LCD OFFSET                                OFF 
EVF OFFSET                                OFF 
 
 
 
 
 
 
 
 
PUSH MENU TO RETURN 
SERVICE MENU
 
 
LCD OFFSET                                OFF 
EVF OFFSET                                OFF 
 
 
 
 
 
 
 
 
PUSH MENU TO RETURN 
OFF 

R signal output to EVF is corrected. 
1: Correction level 1 
2: Correction level 2 
OFF 

INF-12 
5-2. DIAGNOSTIC MENU (VCR mode)
 
5-2-1. How to display the Error Rate. 
This unit can be displayed Error Rate and it shows the playing condition of the VCR. 
In case of the error rate is displayed, BER DISPLAY and SAMPLE SPEED mode is select on DIAGNOSTIC menu. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
How to confirm the Error rate. 
1. Select the TOTAL in item of BER DISPLAY. 
2. Record the color bar signal on LP mode and playback the recorded portion. Confirm that the number of bar on 
display within 10 bars or less. The less bars displayed the better the error rate. 
TOT 
When selecting TOTAL in BER DISPLAY 
mode, it is displayed “TOT” and if select 
VIDEO, it is displayed    “VID” and if select 
AUDIO, it is displayed “AUD”. 
TOT 
CH1 
CH2 
The color of the bar 
In case of green display: Error rate is good 
In case of red display: Error rate is bad 
CH1 
CH2 
Select SLOW or FAST by OPERATION LEVER 
and press SET(STILL) of OPERATION LEVER. 
Factory default setting is “SLOW”. 
DIAGNOSTIC MENU 
 
BER DISPLAY                            OFF 
SAMPLE SPEED           SLOW 
DIF INFO                                      OFF 
CYLINDER                10000H 
TAPE RUN                10000H 
THREADING               10000T 
 
 
 
PUSH MENU TO EXIT 
DIAGNOSTIC MENU 
 
BER DISPLAY                            TOTAL 
SAMPLE SPEED            SLOW 
DIF INFO                                      OFF 
CYLINDER                10000H 
TAPE RUN                10000H 
THREADING               10000T 
 
 
 
PUSH MENU TO EXIT 
OFF 
VIDEO 
AUDIO 
TOTAL 
SLOW 
FAST 
Select the item BER DISPLAY and press
SET(STILL) of OPERATION LEVER. 
Select VIDEO, AUDIO or TOTAL by
OPERATION LEVER and press SET(STILL) of
OPERATION LEVER. 
Factory default setting is “OFF”. 
After selecting BER DISPLAY mode, move to 
item of SAMPLE SPEED by tilt the 
OPERATION LEVER in the DOWN ( 
■ 
:STOP) 
direction. 
The Audio Level Meter is change to error rate 
display, when returning to the normal screen. 
NOTE: 
The display screen is changed only in the VCR 
mode. 
Page of 127
Display

Click on the first or last page to see other AG-DVX100BP / AG-DVX100E / AG-DVX100BE / AG-DVX100AN / AG-DVX102BEN / AG-DVC180BMC service manuals if exist.