INF-9
5-1-2. Software Version Display.
This unit have three pieces of microprocessor and two pieces of EEPROM.
---
CAMERA board
VTR board
Microprocessor
IC301
IC2001(VTR MAIN MICON)
IC3001(VTR SUB MICON)
EEPROM IC307
IC2006
---
5-1-3. Hour Meter Display.
ITEM Display
Data
Description
TAPE RUN
00000H
–
99999H
It displays the time that the tape is running in units of hours.
THREADING 00000T
–
99999T
It displays the number of times the tape is inserted.
CYLINDER 00000H
–
99999H
It displays the time that the cylinder is rotating in units of hours.
It displays same time as in the item HOUR METER of OTHER
FUNCTION menu.
It displays same time as in the item HOUR METER of OTHER
FUNCTION menu.
SERVICE MENU
DEFFECT COMP OFF
AUDIO FILTER ON
VTR SUB MICON 1.001
VTR MAIN MICON 1.77-P-F
VTR EEPRPM 0.007
VTR EEPROM SUM D7EF
CAM MICON 0.D0
CAM EEPROM 0.CA
PUSH MENU TO RETURN
(In case of VTR MAIN MICON)
*.** - P - F
*.** - P - F
Version Number
N = NTSC
P = PAL
P = PAL
F = FLASH
M = MASK
M = MASK
This indicates the
value of the check sum
value of the VTR
EEPROM displayed in
hexadecimal.
value of the check sum
value of the VTR
EEPROM displayed in
hexadecimal.
The version of VTR, and the
CAMERA microprocessor,
VTR and CAMERA EEPROM
are displayed.
CAMERA microprocessor,
VTR and CAMERA EEPROM
are displayed.
TAPE RUN, THREADING are
displayed in addition to the rotating
time of the Cylinder (CYLINDER).
displayed in addition to the rotating
time of the Cylinder (CYLINDER).
SERVICE MENU
CYLINDER 10000H
TAPE RUN 10000H
THREADING 10000T
Y LEVEL 1B
C LEVEL 27
DIF INFO OFF
DEBUG DISP OFF
DEBUG MODE OFF
PUSH MENU TO RETURN
CAMERA C.B.A.(Foil side)
IC307
IC301
VTR C.B.A.(Foil side)
IC2001
IC2006
IC3001
INF-10
5-1-4. Adjustment item for Video Level
Y LEVEL
Y level of VIDEO OUT and S-VIDEO OUTPUT signal can be adjusted on this item.
The displayed value is the same as value for Luminance level adjustment in EVR adjustment.
C LEVEL
C level of VIDEO OUT and S-VIDEO OUTPUT signal can be adjusted on this item.
The displayed value is the same as value for Chroma level adjustment in EVR adjustment.
5-1-5. DIF Status Display.
NORMAL: The DIF STATUS display is updated every five frames.
FAST: The DIF STATUS display is updated every frame.
Factory default setting is “OFF”.
Items Description
Remark
NODECNT
Number of NODE connections.
MY_ID
NODE ID of this unit.
ROOT_ID ROOT
ID
IRM_ID
PHY ID of IRM
IRM(Isochronous Resonance Manager)
IN_CH
Input channel number of Isochronous data.
OUT_CH
Output channel number of Isochronous data.
DIFMODE DIF
mode
RX_IN
Received condition of Isochronous data.
O_BCC
Transmitted condition of Isochronous data.
STYPE
Type of VIDEO signal
FIELD NTSC/PAL
SPEED
Speed of Isochronous data.
IN_SPD in VCR MODE
UID
USER ID of 1394 equipment
AS
Source pack of AUDIO
ASC
Source control pack of AUDIO
VS
Source pack of VIDEO
VSC
Source control pack of VIDEO
HEADER HEADER
pack
Set the item “DIF INFO” to NORMAL
or FAST and it does ON/OFF of the
DIF STATUS display by pressing the
MODE CHECK button on normal
screen.
or FAST and it does ON/OFF of the
DIF STATUS display by pressing the
MODE CHECK button on normal
screen.
SERVICE MENU
CYLINDER 10000H
TAPE RUN 10000H
THREADING 10000T
Y LEVEL 1B
C LEVEL 27
DIF INFO OFF
DEBUG DISP OFF
DEBUG MODE OFF
PUSH MENU TO RETURN
OFF
NORMAL
FAST
INF-11
5-1-6. LCD/EVF Correction
LCD OFFSET
EVF OFFSET
R signal output to LCD is corrected.
1: Correction level 1
2: Correction level 2
1: Correction level 1
2: Correction level 2
SERVICE MENU
LCD OFFSET OFF
EVF OFFSET OFF
PUSH MENU TO RETURN
SERVICE MENU
LCD OFFSET OFF
EVF OFFSET OFF
PUSH MENU TO RETURN
OFF
1
2
2
R signal output to EVF is corrected.
1: Correction level 1
2: Correction level 2
1: Correction level 1
2: Correction level 2
OFF
1
2
2
INF-12
5-2. DIAGNOSTIC MENU (VCR mode)
5-2-1. How to display the Error Rate.
This unit can be displayed Error Rate and it shows the playing condition of the VCR.
In case of the error rate is displayed, BER DISPLAY and SAMPLE SPEED mode is select on DIAGNOSTIC menu.
In case of the error rate is displayed, BER DISPLAY and SAMPLE SPEED mode is select on DIAGNOSTIC menu.
How to confirm the Error rate.
1. Select the TOTAL in item of BER DISPLAY.
2. Record the color bar signal on LP mode and playback the recorded portion. Confirm that the number of bar on
2. Record the color bar signal on LP mode and playback the recorded portion. Confirm that the number of bar on
display within 10 bars or less. The less bars displayed the better the error rate.
TOT
When selecting TOTAL in BER DISPLAY
mode, it is displayed “TOT” and if select
VIDEO, it is displayed “VID” and if select
AUDIO, it is displayed “AUD”.
mode, it is displayed “TOT” and if select
VIDEO, it is displayed “VID” and if select
AUDIO, it is displayed “AUD”.
TOT
CH1
CH2
The color of the bar
In case of green display: Error rate is good
In case of red display: Error rate is bad
In case of green display: Error rate is good
In case of red display: Error rate is bad
CH1
CH2
Select SLOW or FAST by OPERATION LEVER
and press SET(STILL) of OPERATION LEVER.
Factory default setting is “SLOW”.
and press SET(STILL) of OPERATION LEVER.
Factory default setting is “SLOW”.
DIAGNOSTIC MENU
BER DISPLAY OFF
SAMPLE SPEED SLOW
DIF INFO OFF
CYLINDER 10000H
TAPE RUN 10000H
THREADING 10000T
PUSH MENU TO EXIT
DIAGNOSTIC MENU
BER DISPLAY TOTAL
SAMPLE SPEED SLOW
DIF INFO OFF
CYLINDER 10000H
TAPE RUN 10000H
THREADING 10000T
PUSH MENU TO EXIT
OFF
VIDEO
AUDIO
TOTAL
AUDIO
TOTAL
SLOW
FAST
Select the item BER DISPLAY and press
SET(STILL) of OPERATION LEVER.
Select VIDEO, AUDIO or TOTAL by
OPERATION LEVER and press SET(STILL) of
OPERATION LEVER.
Factory default setting is “OFF”.
SET(STILL) of OPERATION LEVER.
Select VIDEO, AUDIO or TOTAL by
OPERATION LEVER and press SET(STILL) of
OPERATION LEVER.
Factory default setting is “OFF”.
After selecting BER DISPLAY mode, move to
item of SAMPLE SPEED by tilt the
OPERATION LEVER in the DOWN (
item of SAMPLE SPEED by tilt the
OPERATION LEVER in the DOWN (
■
:STOP)
direction.
The Audio Level Meter is change to error rate
display, when returning to the normal screen.
NOTE:
The display screen is changed only in the VCR
mode.
display, when returning to the normal screen.
NOTE:
The display screen is changed only in the VCR
mode.