ADJ-5
SECTION 3 ADJUSTMENTS
< RZ970/RW930/RX110 >
1. 4. EEPROM data transfer
1. 4. 1. Equipment to be used
  1. Computer : Use it for the transfer of backup data.
  2. Communication cable : 
   3. Service software : [DataLogBackup.exe] Download from the projector service Web (PASS).
1. 4. 2. Connection preparations
  1. Check the settings of the projector.
 
    1) The [INPUT SELECT] of sub menu [RS-232C] must be set according to the connection method.
    2) The [EMULATE] of sub menu [RS-232C], please set to [DEFAULT]. (in service mode)
    3) Check the RS-232C settings (ID, Baudrate and Parity) and take a note.
 
 
    1) The [DIGITAL LINK MODE] of sub menu [NETWORK], is select to [AUTO] or [ETHERNET].
    2) Check the network IP address of the projector and take a note.
    3) Set the IP address of computer to approximate value of projector IP address.
        
    [Note]
      •  If you have changed the each menu settings, please return settings of the original (customers) after work.
      •  Set up your computer not to standby or shutdown..
  2. Connect the projector and the PC by using a communication cable.
Error message
Probable cause
PW1  Sensor value is wrong
Measured value of luminance sensor is abnormal.
Replace the sensor and perform index adjustment again.
PW1  Sensor value is wrong
CW   Sensor value is wrong
PW1  Adjustment was failed
Calculation error of PW1.  Replace the PW1 and perform index adjustment again.
PW1  Sensor value is wrong
Calculation error of PW2.  Replace the PW2 and perform index adjustment again.
CW   Adjustment was failed
Calculation error of CW.  Replace the CW and perform index adjustment again.
  [When the message "AUTO INDEX CALIBRATION INCOMPLETE" is displayed]
Serial terminal connection
D-sub 9 pin (male/female RS-232C straight)
LAN terminal connection
LAN cable. (When connecting directly, use a cross cable)
Serial terminal connection
LAN terminal connection
Projector
SERIAL IN
Communication cable (straight)
Computer
D-Sub 9P
(male)
LAN cable (straight)
LAN cable (straight)
Hub
Projector
LAN
Computer
Serial terminal connection example
LAN terminal connection example
ADJ-6
SECTION 3 ADJUSTMENTS
< RZ970/RW930/RX110 >
1. 4. 3. Backup the EEPROM data (It is before circuit board exchange)
  1. Switch the projector to "Normal-Standby" mode (Power indicator is lighting in red).
  2. Activate a [DataLogBackup.exe] Service software.
  3. Select "Option " → " Setting" and select the connection method, and enter the setting information of the projector.
 
 
    • Select [Serial] and setup the port, baud rate and parity.
 
 
    • Select [LAN] and set up IP Address, Username, Password and Command Port.
 
    [Note]
      • If the Username and Password has been changed, please select serial terminal connection.
  4. Select a model number and ID.
Items
Default
SERIAL
Port
Baud Rate
9600bps
Parity
None
LAN
IP Address
192.168.0.8
Username
admin1
Password
panasonic
Command Port
1024
Serial terminal connection
LAN terminal connection
ADJ-7
SECTION 3 ADJUSTMENTS
< RZ970/RW930/RX110 >
  5. Select the "Backup (EEPROM)” tab and put a checkmark to the "REPLACE A-PWB" of "COPY MODE" item.
      Then click the [READ EEPROM] button.
  6. Select the save place and click [Save(S)] button.
  7. Once the progress bar reaches the right side end, it is a read completion of the data.
    • [WRITE EEPROM] button and [READ EEPROM] button will return to normal display from gray.
  8. Select the "Quit" of "File" menu and quit the software.
ADJ-8
SECTION 3 ADJUSTMENTS
< RZ970/RW930/RX110 >
1. 4. 4. Restore the backup EEPROM data (After circuit board replace)
  1. Switch the projector to "Normal-Standby" mode (Power indicator is lighting in red).
  2. Activate a [DataLogBackup.exe] Service software.
  3. Select "Option " → " Setting" and select the connection method, and enter the setting information of the projector.
  4. Select a model number and ID.
  5. Select the "Backup (EEPROM)” tab and put a checkmark to the "REPLACE A-PWB" of "COPY MODE" item.
      Then click the [WRITE EEPROM] button.
6. Select the saved file and click [OPEN(O)] button.
7. Once the progress bar reaches the right side end, it is a write completion of the data.
  • [WRITE EEPROM] button and [READ EEPROM] button will return to normal display from gray.
8. Select the "Quit" of "File" menu and quit the software.
9. Restart the main power of projector and check that it operates properly.