Panasonic PT-MZ16K / PT-MZ13K / PT-MZ10K (serv.man2) Service Manual ▷ View online
INF-15
SECTION 1 SERVICE INFORMATION
<MZ16K/MZ13K/MZ10K>
4. FLICKER ADJUST
• Perform the flicker adjustment. ( Refer to "SECTION 3 Adjustment")
* Take this adjustment after replacing the optical block or A-PCB.
5. POWER OFF MESSAGE
• Setting of the shutter function with standby operation
- SHUTTER KEEP: When pushing the standby key while the shutter mode is on, the projector keeps the shutter mode on
and sets into standby mode.
- SHUTTER OPEN: When pushing the standby key while the shutter mode is on, the projector opens the shutter and displays
the "Power OFF confirmation message". (Default)
* This projector does not provide the mechanical shutter but it operates the same function.
6. ERROR OSD
• Enables to display the error information of the LIGHT indicators on the screen (It is useful when using the projector with rear
projection mode)
- ON : "LD1/LD2 ERROR" is displayed on the screen if the lighting error occurs. (It will disappear when any of the control
buttons is pressed.)
- OFF : No message is displayed on the screen if the lighting error occurs. (Default)
7. MODEL
• Setting up the model no. of the projector. (Refer to "SECTION 3 Adjustment")
* Take this setting after replacing the A-PCB. The setting will be apply after turning on the Main sw. It is not necessary if the
EEPROM data can be transferred from the original PCB.
8. LIGHT RUNTIME RESET
• Reset the runtime of the LD unit after replacing the LD unit. The resetting will be apply after turning on the Main sw. (Refer to
"SECTION 3 Adjustment")
- LD1-1 : Resets the runtime of LD1-1 unit.
- LD1-2 : Resets the runtime of LD1-2 unit.
- LD2-1 : Resets the runtime of LD2-1 unit.
9. PANEL TYPE SETTING
• Setting up the LCD panel type (L-Type or R-Type). ( Refer to "SECTION 3 Adjustment")
10. RGB PIXEL ADJUST
• Adjusts the convergence. Each pixel cab be moved +- 2 dots vertically and horizontally.( Refer to "SECTION 3 Adjustment")
11. GHOST FB CALIBRATION
• Performs the panel ghost feedback calibration.( Refer to "SECTION 3 Adjustment")
12. CLOG SENSOR CALIBRATION
• Calibrates the clog sensor circuit. ( Refer to "SECTION 3 Adjustment")
13. MUTE TIME OFFSET
• Setting up the black mute time expansion.
If the noise appears at input signal switching, etc., this setting can be invisible it to expand the mute time.
- DISABLE: Default
- 0.5s: expand the mute period in 0.5 second.
|
- 5.0 S: Expand the mute period in 5.0 seconds.
INF-16
SECTION 1 SERVICE INFORMATION
<MZ16K/MZ13K/MZ10K>
14. INDICATOR SETTING
• Set this when you want to turn off the indicator LED.
– INDICATOR MODE
– NORMAL : The indicator maintains lighting (Default)
– OFF : The indicator will be forcibly turned off.
– TIMEOUT : The indicator turns off when no operation is taken for a certain time.
– NO ACTIVITY TIME
Setup the time to turn off when INDICATOR MODE setting is TIMEOUT.
You can set the time up to 15 minutes in 1 minute. (Default 15 MIN)
*If INDICATOR MODE setting is NORMAL or OFF, this will be grayed out.
15. COMMAND CONTROL TIMEOUT
• Setting up the communication specifications of the command control.
- 0 SEC : 1 command 1 session mode. (Default)
- 30 SEC : Keeps a session for 30 seconds.
- Switches the time with qw button.
16. DIGITAL LINK OPTION
• Setting up if the DIGITAL LINK firmware update failed.
- 0: Normal mode (Default)
- 1: Writing mode by the special tool
17. HDMI HOT PLUG CONTROL
• At the turning on the projector, setup when the abnormal HDMI signal (no information frame, etc.) is output from source
equipment, it controls the Hot Plug and outputs the signal again.
- DISABLE : Hot Plug is "High" during connecting to the source equipment.*1
- POWER ON : Hot Plug is switched from "Low" to "High" once when starting up the main power supply. (Default) *1, *2
*1 : When changing the setting of "EDID Selection" or "EDID Mode" on the HDMI IN menu, the Hop Plug becomes
"Low".
*2 : The source equipment may output the signal again to the connected equipment (monitors, projectors).
18. WAVE PLACE CONTROL
• Setting up the color correction function with the wave plate turning operation.
- OFF: Disable the correction function.
- ON: Enable the correction function (Default)
19. LIGHT OUT CONTROL
• Setting up the operation if the dynamic contrast is set off.
- OFF: Native contrast, measurement mode.
- ON: Normal mode (Default)
INF-17
SECTION 1 SERVICE INFORMATION
<MZ16K/MZ13K/MZ10K>
3.3.2. Additional function of each menu
1. [PICTURE] menu
[AI WINDOW] is added to the [USER] setting in sub menu [DYNAMIC CONTRAST].
• [AI WINDOW]
Sets up the APL detective area. (AUTO/MANUAL, further settings are available in MANUAL mode)
DYNAMIC CONTRAST
AUTO CONTRAST
BRIGHT SIGNAL LEVEL
DISABLE
OFF
0
OFF
30%
LIGHTS OUT TIMER
LIGHTS OUT SIGNAL LEVEL
LIGHTS OUT FADE-IN
LIGHTS OUT FADE-OUT
MANUAL INTENSITY
DYNAMIC GAMMA
AI WINDOW
MULTI PROJECTOR SYNC
MENU SELECT
SUB MENU
ENTER
AI WINDOW
AI MODE
VERTICAL SIZE
AUTO
HORIZONTAL SIZE
VERTIACAL POSITION
HORIZONTAL POSITION
MENU SELECT
CHANGE
AI WINDOW
AI MODE
VERTICAL SIZE
5
5
MANUAL
90%
90%
HORIZONTAL SIZE
VERTIACAL POSITION
HORIZONTAL POSITION
MENU SELECT
CHANGE
2. [POSITION] menu
2 items below are added in the sub menu.
• [HDMI EQUALIZER]
When noise contamination to HDMI input caused by long cable or ex-
ternal device, set this item so that the noise decreases. (AUTO/0 - 15)
• [DVI EQUALIZER]
When noise contamination to DVI input caused by long cable or ex-
ternal device, set this item so that the noise decreases. (AUTO/LOW/
MID/HIGH)
INF-18
SECTION 1 SERVICE INFORMATION
<MZ16K/MZ13K/MZ10K>
(2) The following special mode are added to sub menu [RS232C] - [EMULATE].
- MODE HI (other companies)
- MODE MI (other companies)
- MODE NE (other companies)
- MODE SO (other companies)
- MODE EP (other companies)
- MODE CH (other companies)
- MODE SA (other companies)
- OTHER (other companies/models)
- MODE_SH (other companies)
* The sub-CPU firmware can not be updated when the emulate setting is selected to "MODE_**" or OTHER.
3. [PROJECTOR SETUP] menu
(1) The following two items are added to the sub-menu.
• [COOLING CONDITION]
- Fan control can be set manually according to the projection method. (Usually set to [AUTO].)
• [HIGH ALTITUDE MODE]
- Altitude can be set manually. (Usually set to [AUTO].)
Click on the first or last page to see other PT-MZ16K / PT-MZ13K / PT-MZ10K (serv.man2) service manuals if exist.