-65-
Troubleshooting
No audio output
Follow the procedures below.
Check IC5202 and peripheral circuit.
Check if the power supply of L5007and L5008 reaches 5.5V
Yes
Check related circuits of Q50011/Q5010/Q5005/Q5001.
Check the voltage of pin 
4 and pin9 is more than 
3V. 
No
1. Check if the loudspeaker cable is plugged or broken. 
2. Check if the loudspeaker is damaged.
Check pin 43 and 46 of 
IC5007 have audio signal 
output. 
No
Yes
-66-
Troubleshooting
Shutdown system
This projector provides the shutdown function to set into the standby mode immediately for product safety when 
the projector has the fan operation error or lamp lightning error.
LED indication status
Shutdown detection
Probable cause
OSD warning
Not lighting or flashing
Power supply block
Fuse : Rated 6.3A
Blown out of fuse
(with another reason)
Thermal switch 
      Over 120ºC
Blown out of thermal fuse (with another 
reason) 
Check usage environment
Ballast block
Fuse 
Intake duct clogging
Ballast block error
ON(G)/STANDBY(R) LED 
blinks in Orange
WARNING LED blinks in 
Red
Lamp cover switch 
       Shutdown immediately if switch 
is OFF
Lamp cover is not installed securely
ON(G)/STANDBY(R) LED 
blinks in Orange
WARNING LED is Off
Intake air temperature sensor
Intake air temperature error 
      Filter clogging 
      High temperature of environment 
      Ventilation holes are blocked
Internal temperature sensor A
Internal temperature sensor A error 
      Filter clogging 
      High temperature of environment 
      Ventilation holes are blocked
Internal temperature sensor B
Internal temperature sensor B error 
      Filter clogging 
      High temperature of environment 
      Ventilation holes are blocked
ON(G)/STANDBY(R) LED 
lights in Orange
WARNING LED is Off
Each FAN LOCK signal 
      No signal
FAN A (F3001/F3002)
Connector disconnection
Fan rotation error
Each FAN LOCK signal 
      No signal
FAN B (F3003/F3004)
Connector disconnection
Fan rotation error
Each FAN LOCK signal 
      No signal
FAN C (F3005)
Connector disconnection
Fan rotation error
ON(G)/STANDBY(R) LED 
lights in Orange
WARNING LED lights in 
Red
Iris operation error
Iris unit error
Connector disconnection
ON(G)/STANDBY(R) LED 
lights in Orange 
WARNING LED is Off 
Detects Power error signal "P-FAIL". Internal power supply line error
ON(G)/STANDBY(R)  LED 
lights in Red 
WARNING LED blinks in 
Red
Lamp runtime
      Over 6600 hours (It will auto-
matically shutoff in 10 min.)
Use of lamp runtime over
Indicate lamp replacing icon
-67-
Troubleshooting
Error log
This projector provides the error history log function. To 
check the logs, you need to enter the service mode and 
select Group No. "220" and item No. "0" to "49". The error 
code is displayed on the data column. The description of 
the error code is listed on the table below.
* How to enter the service mode and select the group, item 
and data value, see "Electrical Adjustment".
1. Enter the Service Mode, and select Group No. "220" and Item No. "50".
2 The history log will be reset when the data value is set to "10". The value automatically returns to "0".
Group
No.
Item
No.
Data
(Error code)
220
0
1
2
3
:
:
49
1001 
← Latest error code
1002
2000
2001
  :
  :
2201
Error
Error 
code
Error information
0
Normal
Power error
1000
Main Power supply error
1001
FAN A/B Power supply error  (F3001/F3002/F3003/F3004)
1002
FAN C Power supply error (F3005)
1003
IRIS Power supply error
Power management error
1100
Shutdown on Power management (Depending on the setting)
External temp error
2000
Intake temperature error. Detects error on Intake temp sensor
2001
Intake temperature error. Detects abnormal value on Intake temp sensor
Internal temp A error
2100
Internal temperature error. Detects error on temp sensor A
2101
Internal temperature error. Detects abnormal value on Iemp sensor A
Internal temp B error
2200
Internal temperature error. Detects error on temp sensor B
2201
Internal temperature error. Detects abnormal value on temp sensor B
Lamp error
3000
Lamp on failure
3100
Lamp usage time is over
How to reset the error log
-68-
Serial control
<SERIAL IN> terminal
The <SERIAL IN> terminal of the projector conforms with RS--232C so that the projector can be connected to 
and controlled from a computer. 
 
J
Connection
 
J
Pin assignments and signal names
D-Sub 9-pin (female)
Outside view
Pin No.
Signal names
Contents
NC
TXD
Transmitted data
RXD
Received data
NC
GND
Earth
NC
CTS
Connected internally
RTS
NC
 
J
Communication conditions (Factory default)
Signal level
RS-232C-compliant
Character length
8 bits
Sync. method
Asynchronous
Stop bit
1 bit
Baud rate
19,200 bps
X parameter
None
Parity
None
S parameter
None
D-Sub 9 pin (male)
D-Sub 9 pin (female)
Connecting terminals on projector
Computer
Communication cable (straight)