DOWNLOAD Panasonic PT-EX16KU / PT-EX16KE (serv.man4) Service Manual ↓ Size: 37.53 MB | Pages: 127 in PDF or view online for FREE

Model
PT-EX16KU PT-EX16KE (serv.man4)
Pages
127
Size
37.53 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / LCD PROJECTOR
File
pt-ex16ku-pt-ex16ke-sm4.pdf
Date

Panasonic PT-EX16KU / PT-EX16KE (serv.man4) Service Manual ▷ View online

-53-
Optical Parts Disassembly
L
2-2 LCD panels removal
Remove 3 screws-C (M2x6) on each LCD panel and remove the LCD panel.
C
C
C
C
C
C
C
C
C
R-LCD panel
B-LCD panel
LCD panel type check
There are 2 types combination of the LCD panel/prism assembly and the optical parts, named Type-R and Type-L. 
Since both have no compatibility, each type should be combined with the same type, and the specific parts should 
be used. If not, the poor optical characteristics may degrade the quality of a projected image.
Confirm the "R" label or "L" label on top of the LCD panel/ prism assembly and optical unit.
Confirm that both marking "R" is
 matched.
LCD panel/prism assy Type-R
Confirm that both marking "L" is
 matched.
LCD panel/prism assy Type-L
G-LCD panel
L
R
R
-54-
Optical Parts Disassembly
3  Polarized glass(IN)/Optical filter assy removal
Remove 2 screws-A (M2.5x6) on each stopper and take the polarized glasses up-
ward off.
A
A
A
Polarized glass(IN)/
Optical filter assy
*  Note on handling the polarized glass (IN) assy
Care the Polarized glass (IN) assy to maintain with the follow-
ing points.
-  When removing the dust on the outer surface of the Polarized 
glass (IN) assy, wipe with the soft cloth gently.
-  When removing the dust on the inner surface of the Polarized 
glass (IN) assy, The inner surface (light incoming side) of 
the Polarized glass(IN/B)1 and Polarized glass-(IN/G)1 have 
a very sensitive surface. Never touch or wipe the surfaces. 
When removing the dust, use a commercial (inert gas) air 
spray to remove them. Never use organic solvents. Grab the 
edge of the glass with new gloves when handling the polar-
ized glass. 
Optical filter (ICV) assy
Polarized glass (IN) 
assy
(M3x6)
Never touch or wipe 
the surface of this side
Polarized 
glass (IN)1
-55-
Optical Parts Disassembly
There are 2 types combination of the LCD panel/prism assembly named Type-R and Type-L. Mount the polarized 
glasses and optical filters according to the type of the LCD panel assembly as shown in the figure below 
3-1  Polarized glass(IN)/Optical filter mounting
Prism side
Optical filter-(ICV)
TYPE-L
Polarized glass Assy for Red
Polarized glass Assy for Green
Polarized glass Assy for Blue
Pre-Polarized glass-(IN/R)
Polarized glass-(IN/R)
(M2x2)
(M2x2)
(M2x2)
(M2x2)
(M3x6)
(M2x2)
(M3x6)
(M2x2)
(M2x2)
(M2x2)
Polarized glass-(IN/G)1*
Polarized glass-(IN/G)2
Optical filter-(ICV)
Optical filter-(ICV)
Polarized glass-(IN/B)1*
Optical filter-(IN/B)2
(M2x2)
(M3x6)
(M2x2)
(M2x2)
(M2x2)
Film side
Film side
Marking
(Behind)
Marking
(Behind)
Film side
No mounting 
direction
Marking
(Black)
Marking
(Red)
Marking
(Black)
Film side
Film side
Film side
Prism side
Prism side
-56-
Optical Parts Disassembly
Prism side
Optical filter-(ICV)
TYPE-R
Polarized glass Assy for Red
Polarized glass Assy for Green
Polarized glass Assy for Blue
Pre-Polarized glass-(IN/R)
Polarized glass-(IN/R)
(M2x2)
(M2x2)
(M2x2)
(M2x2)
(M3x6)
(M2x2)
(M3x6)
(M2x2)
(M2x2)
(M2x2)
Polarized glass-(IN/G)1*
Polarized glass-(IN/G)2
Optical filter-(ICV)
Optical filter-(ICV)
Polarized glass-(IN/B)1*
Optical filter-(IN/B)2
(M2x2)
(M3x6)
(M2x2)
(M2x2)
(M2x2)
Film side
Film side
Marking
(Behind)
Marking
(Behind)
Film side
No mounting 
direction
Marking
(Red)
Marking
(Black)
Marking
(Red)
Film side
Film side
Film side
Prism side
Prism side
Page of 127
Display