DOWNLOAD Panasonic PT-EX12KU / PT-EX12KE (serv.man3) Service Manual ↓ Size: 31.31 MB | Pages: 127 in PDF or view online for FREE

Model
PT-EX12KU PT-EX12KE (serv.man3)
Pages
127
Size
31.31 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / LCD PROJECTOR
File
pt-ex12ku-pt-ex12ke-sm3.pdf
Date

Panasonic PT-EX12KU / PT-EX12KE (serv.man3) Service Manual ▷ View online

-97-
Electrical Adjustment
Grp / No. Item
Function
Range
Initial
Note
5 Press Add Data
Add Data by Air Pressure (Read only) 
0 - 1023
-
6 Filter Scroll Timer
Timer for Filter Scroll [hour] (Read only)
0 - 32767
-
7 Air Inlet Err Difference Data
Difference to judge the Intake Error
0 - 1023
-
249
Pressure Sensor
0 Pressure Monitor
Pressure Sensor Value [ADC] (Read only)
-
-
1 Pressure Monitor
Pressure Sensor Value with Compensate [ADC] (Read only)
-
-
2 Presss Offset
Offset Value
- 1023 - 1023
0
3 Press calib Effective Diff
Effective Range [ADC]
0 -123
1023
4 Press Sensor Calibration Log
0: Executed & Normal Range (Read ony)
10: Out of Range Minimum
20: Out of Range Maximum
99: Not execute Calibration
-
99
250
Fan Voltage
0 Fan 1 Min Adj
0 - 255
54
1 Fan 1 Max Adj
0 - 255
206
2 Fan 2 Min Adj
0 - 255
54
3 Fan 2 Max Adj
0 - 255
206
4 Fan 3 Min Adj
0 - 255
55
5 Fan 3 Max Adj
0 - 255
208
6 Fan 4 Min Adj
0 - 255
62
7 Fan 4 Max Adj
0 - 255
214
8 Fan 5 Min Adj
0 - 255
62
9 Fan 5 Max Adj
0 - 255
208
10 Fan 6 Min Adj
0 - 255
40
11 Fan 6 Max Adj
0 - 255
200
12 Fan 7 Min Adj
0 - 255
40
13 Fan 7 Max Adj
0 - 255
201
14 Fan 8 Min Adj
0 - 255
39
15 Fan 8 Max Adj
0 - 255
211
252
Fan Option
1 Safety Switch
Safety Application use
0 - 8
0
2 Fan Manual Switch
Fan Manual SW   (0: Auto  1: Manual)
0 - 1
0
3 Fan 1 Manual Voltage
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
0 - 255
100
4 Fan 2 Manual Voltage
0 - 255
100
5 Fan 3 Manual Voltage
0 - 255
100
6 Fan 4 Manual Voltage
0 - 255
100
7 Fan 5 Manual Voltage
0 - 255
100
8 Fan 6 Manual Voltage
0 - 255
100
9 Fan 7 Manual Voltage
0 - 255
100
10 Fan 8 Manual Voltage
0 - 255
100
253
Fan Temp Error Setting 
(Memorized)
Normal Ceiling
Top
Bottom
0 Temp A Warning 
Temp A (Room) to judge the Temp Error
30 - 100
44
44
44
44
1 Temp C-A Warnin
Temp C-A (Panel - Room) to judge the Temp Error
0 - 100
20
20
20
20
254
Fan Control Range Setting 
(Temp/Voltage)
Normal Ceiling
Top
Bottom
0 Normal  Fan Control Min Temp
Temp Sensor Control Start/End Temp at Normal
20 - 100
27
27
27
27
1 Normal  Fan Control Max Temp
20 - 100
42
42
42
42
2 Normal Fan 1 Min
Fan Voltage Set at Normal (Min/Max) (Duty)
0 - 255
60
60
60
60
3 Normal Fan 1 Max
0 - 255
132
132
132
132
4 Normal Fan 2 Min
0 - 255
60
60
60
60
5 Normal Fan 2 Max
0 - 255
132
132
132
132
6 Normal Fan 3 Min
0 - 255
60
60
60
60
7 Normal Fan 3 Max
0 - 255
132
132
132
132
8 Normal Fan 4 Min 
0 - 255
85
85
85
85
9 Normal Fan 4 Max 
0 - 255
132
132
132
132
10 Normal Fan 5 Min 
0 - 255
80
80
80
80
11 Normal Fan 5 Max
0 - 255
132
132
132
132
12 Normal Fan 6 Min 
0 - 255
115
115
105
105
13 Normal Fan 6 Max
0 - 255
115
115
105
105
14 Normal Fan 7 Min 
0 - 255
115
115
105
105
15 Normal Fan 7 Max
0 - 255
115
115
105
105
16 Normal Fan 8 Min 
0 - 255
70
70
70
70
17 Normal Fan 8 Max
0 - 255
132
132
132
132
18 Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp at Eco
20 - 100
27
27
27
27
19 Eco Fan Control Max Temp
20 - 100
42
42
42
42
20 Eco Fan 1 Min
0 - 255
50
50
50
50
21 Eco Fan 1 Max
0 - 255
132
132
132
132
22 Eco Fan 2 Min
Fan Voltage Set at Eco (Min/Max) Duty)
0 - 255
50
50
50
50
23 Eco Fan 2 Max
0 - 255
132
132
132
132
24 Eco Fan 3 Min
0 - 255
50
50
50
50
-98-
Electrical Adjustment
Grp / No. Item
Function
Range
Initial
Note
25 Eco Fan 3 Max
0 - 255
132
132
132
132
26 Eco Fan 4 Min 
0 - 255
60
60
60
60
27 Eco Fan 4 Max 
0 - 255
125
125
125
125
28 Eco Fan 5 Min 
0 - 255
70
70
70
70
29 Eco Fan 5 Max 
0 - 255
125
125
125
125
30 Eco Fan 6 Min 
0 - 255
80
80
70
70
31 Eco Fan 6 Max 
0 - 255
80
80
70
70
32 Eco Fan 7 Min 
0 - 255
80
80
70
70
33 Eco Fan 7 Max 
0 - 255
80
80
70
70
34 Eco Fan 8 Min 
0 - 255
55
55
55
55
35 Eco Fan 8 Max 
0 - 255
125
125
125
125
255
Fan Start/Cooling Setting
0 Fan 1 Initial Volt
Fan Start Voltage (Duty)
0 - 255
50
1 Fan 2 Initial Volt
0 - 255
50
2 Fan 3 Initial Volt
0 - 255
50
3 Fan 4 Initial Volt
0 - 255
75
4 Fan 5 Initial Volt
0 - 255
70
5 Fan 6 Initial Volt
0 - 255
80
6 Fan 7 Initial Volt
0 - 255
80
7 Fan 8 Initial Volt
0 - 255
55
8 Cooling Time
Cooling Time Setting (x30 sec.)  1: 30  3: 90  15: 450
1 - 15
3
10 Temp Error Cooling Time
Cooling Time Setting When the Temp Error occurs (x30 sec.)  
 1: 30  3: 90  15: 450
1 - 15
3
11 OnStart Cooling Start Threshold
0 - 100
38
12 After shutdown cooling
Cooling Operation after Shut Down (0: No, 1: Yes)
0 - 1
1
260
Auto Calibration (Common)
0 Execute Calibration
Execute Calibration when the Value is changed to 1. (For PC 
White 100%)
0 - 1
0
1 Loop Count
Max Times of Calibration
1 - 30
8
2 Auto Status
Calibration Log (Read only)
0: Calibration End Correctly  1: On Adjusting  9: Calibration Error
0 / 1 / 9
0
3 AutoWait
Waiting time
1 - 20
3
4 CHECK - Tolerance
Tolerance of Offset
1 - 255
4
5 Time out wait
Wait Time until Time out [sec.]
1 - 255
20
261
Auto Calibration (RGB) 
<10bits>
0 OFFSET AREA H START
Black Level Acq. Area H Start
0 - 1000
975
1 OFFSET AREA V START
Black Level Acq. Area V Start
0 - 1000
500
2 GAIN AREA H START
White Level Acq. Area H Start
0 - 1000
25
3 GAIN AREA V START
White Level Acq. Area V Start
0 - 1000
500
4 Image AREA H WIDTH
Black/White Level Area Width
0 - 4095
13
5 Image AREA V HEIGHT
Black/White Level Area Height
0 - 4095
9
6 OFFSET Target
Black Level Adj target
0 - 1023
0
7 OFFSET Tolerance
Black Level Adj telerance
1 - 1023
1
8 GAIN Target
White Level Adj target
0 - 1023
942
9 GAIN Tolerance
White Level Adj telerance
1 - 1023
1
10 Image Level Tolerance
Acq. Image Level Adj Tolerance
1 - 255
4
262
Auto Calibration (CVBS/SVIDEO)  <10bits>
0 Y Image Area Start X
Y Image Area H Start
0 - 1000
10
1 Y Image Area Start Y
Y Image Area V Start
0 - 1000
200
6 Image Area H WIDTH
Image Level Acq. Width
0 - 4095
8
7 Image Area V HEIGHT
Image Level Acq. Height
0 - 4095
9
8 Y Target Level
Y Level Adj target
0 - 1023
745
11 Gain Tolerance
Level Adj Tolerance
1 - 255
1
12 Image Level Tolerance
Acq. Image Level Adj Tolerance
1 - 255
4
264
Auto Calibration (YCbCr) 
<10bits>
(YCbCr 1080I)
0 Y-OFFSET AREA H START
Y - Offset Acq Area H Start
0 - 1000
925
1 Y-OFFSET AREA V START
Y - Offset Acq Area V Start
0 - 1000
500
2 CB - OFFSET AREA H START
CB - Offset Acq. Area H Start
0 - 1000
925
3 CB - OFFSET AREA V START
CB - Offset Acq. Area V Start
0 - 1000
500
4 CR - OFFSET AREA H START
CR - Offset Acq. Area H Start
0 - 1000
925
5 CR - OFFSET AREA V START
CR - Offset Acq. Area V Start
0 - 1000
500
6 Y - GAIN AREA H START
Y
0 - 1000
50
7 Y - GAIN AREA V START
0 - 1000
500
8 CB - GAIN AREA H START
0 - 1000
800
9 CB - GAIN AREA V START
0 - 1000
500
10 CR - GAIN AREA H START
0 - 1000
700
11 CR - GAIN AREA V START
0 - 1000
500
12 Image AREA H WIDTH
YCBCR Level Acq. Width
0 - 4095
13
13 Image AREA V HEIGHT
YCBCR Level Acq. Height
0 - 4095
9
-99-
Electrical Adjustment
Grp / No. Item
Function
Range
Initial
Note
14 Y - OFFSET TARGET
0 - 1023
0
15 CB OFFSET TARGET
0 - 1023
512
16 CR OFFSET TARGET
0 - 1023
512
17 Y - GAIN TARGET
0 - 1023
870
18 CB - GAIN TARGET
0 - 1023
947
19 CR - GAIN TARGET
0 - 1023
947
20 OFFSET Tolerance
OFFSET Adj Tolerance
1 - 255
1
21 GAIN Tolerance
GAIN Adj Tolerance
1 - 255
1
22 Image Level Tolerance
Acq. Image Level Adj Tolerance
1 - 255
4
290
Color Matching Target Data
0 Target Red - X
Target Data Adj for Color Matching Function
0 - 1000
650
1 Target Red - Y
0 - 1000
340
10 Target Green - X
0 - 1000
340
11 Target Green - Y
0 - 1000
625
20 Target Blue - X
0 - 1000
150
21 Target Blue - Y
0 - 1000
90
30 Target White: PC/AV Standard - X
0 - 1000
315
31 Target White: PC/AV Standard - Y
0 - 1000
329
32 Target White: PC/AV Real/Cinema - X
0 - 1000
315
33 Target White: PC/AV Real/Cinema - Y
0 - 1000
329
34 Target White: PC/AV Dynamic - X
0 - 1000
315
35 Target White: PC/AV Dynamic - Y
0 - 1000
329
100 Target Data Update
After setting the data, target data  will be updated when the value 
is set to 10.
-
300
Closed Caption
2 Multi WIndow Caption
at PIP Mode 0: Off, 1: On
0 - 1
1
430
Model No. Setting [No Name]
0 Display Model No. Setting
0: Not defined
1: PT-EX12K
2: PT-EX12KU
3: PT-EX12KE
4: PT-EX12KEJ
5: PT-SLX12KC
0
-
1 Model No. Setting
Model No. si set when the value is seto to 10.
0 - 10
0
431
Model No. Setting [PT-EX12K]
0 Display Model No. Setting
Reger to Group 430-0
0
-
1 Model No. Setting
Model No. si set when the value is seto to 10.
0 - 10
0
432
Model No. Setting [PT-EX12KU]
0 Display Model No. Setting
Reger to Group 430-0
0
-
1 Model No. Setting
Model No. si set when the value is seto to 10.
0 - 10
0
433
Model No. Setting [PT-EX12KE]
0 Display Model No. Setting
Reger to Group 430-0
0
-
1 Model No. Setting
Model No. si set when the value is seto to 10.
0 - 10
0
434
Model No. Setting [PT-EX12KEJ]
0 Display Model No. Setting
Reger to Group 430-0
0
-
1 Model No. Setting
Model No. si set when the value is seto to 10.
0 - 10
0
435
Model No. Setting [PT-SLX12KC]
0 Display Model No. Setting
Reger to Group 430-0
0
-
1 Model No. Setting
Model No. si set when the value is seto to 10.
0 - 10
0
500
SCART(480i)
0 Total Dots
0 - 4095
858
1 Disp Dots
0 - 4095
674
2 H Back Porch
0 - 4095
154
3 V Back Porch
0 - 4095
38
4 Disp Line
0 - 4095
456
5 Clamp Position
0 - 4095
80
6 Clamp Width
0 - 4095
20
8 VSBEG
0 - 15
1
9 Filed Enable
0 - 1
1
10 FLDBEG
0 - 15
1
11 FLDEND
0 - 15
9
12 PHASE
0 - 63
16
22 (Sub) H Back Porch
0 - 4095
140
23 (Sub) V Back Porch
0 - 4095
42
25 (Sub) Clamp Position
0 - 4095
0
26 (Sub) Clamp Width
0 - 4095
0
-100-
Electrical Adjustment
Grp / No. Item
Function
Range
Initial
Note
28 (Sub) VSBEG
0 - 15
1
29 (Sub) Filed Enable
0 - 1
0
30 (Sub) FLDBEG
0 - 15
4
31 (Sub) FLDEND
0 - 15
10
32 (Sub) PHASE
0 - 63
16
501
SCART (575i)
0 Total Dots
0 - 4095
868
1 Disp Dots
0 - 4095
670
2 H Back Porch
0 - 4095
166
3 V Back Porch
0 - 4095
52
4 Disp Line
0 - 4095
540
5 Clamp Position
0 - 4095
90
6 Clamp Width
0 - 4095
20
8 VSBEG
0 - 15
1
9 Filed Enable
0 - 1
1
10 FLDBEG
0 - 15
1
11 FLDEND
0 - 15
9
12 PHASE
0 - 63
16
22 (Sub) H Back Porch
0 - 4095
156
23 (Sub) V Back Porch
0 - 4095
62
25 (Sub) Clamp Position
0 - 4095
0
26 (Sub) Clamp Width
0 - 4095
0
28 (Sub) VSBEG
0 - 15
1
29 (Sub) Filed Enable
0 - 1
0
30 (Sub) FLDBEG
0 - 15
4
31 (Sub) FLDEND
0 - 15
10
32 (Sub) PHASE
0 - 63
16
510
RGB Video (480i)
0 Total Dots
0 - 4095
858
1 Disp Dots
0 - 4095
712
2 H Back Porch
0 - 4095
144
3 V Back Porch
0 - 4095
38
4 Disp Line
0 - 4095
486
5 Clamp Position
0 - 4095
1
6 Clamp Width
0 - 4095
31
8 VSBEG
0 - 15
1
9 Filed Enable
0 - 1
1
10 FLDBEG
0 - 15
1
11 FLDEND
0 - 15
10
12 PHASE
0 - 63
16
22 (Sub) H Back Porch
0 - 4095
146
23 (Sub) V Back Porch
0 - 4095
40
25 (Sub) Clamp Position
0 - 4095
91
26 (Sub) Clamp Width
0 - 4095
20
28 (Sub) VSBEG
0 - 15
1
29 (Sub) Filed Enable
0 - 1
1
30 (Sub) FLDBEG
0 - 15
3
31 (Sub) FLDEND
0 - 15
10
32 (Sub) PHASE
0 - 63
32
511
RGB Video (575i)
0 Total Dots
0 - 4095
866
1 Disp Dots
0 - 4095
706
2 H Back Porch
0 - 4095
162
3 V Back Porch
0 - 4095
42
4 Disp Line
0 - 4095
576
5 Clamp Position
0 - 4095
1
6 Clamp Width
0 - 4095
31
8 VSBEG
0 - 15
1
9 Filed Enable
0 - 1
1
10 FLDBEG
0 - 15
1
11 FLDEND
0 - 15
10
12 PHASE
0 - 63
32
22 (Sub) H Back Porch
0 - 4095
160
23 (Sub) V Back Porch
0 - 4095
44
25 (Sub) Clamp Position
0 - 4095
99
26 (Sub) Clamp Width
0 - 4095
20
28 (Sub) VSBEG
0 - 15
1
29 (Sub) Filed Enable
0 - 1
1
30 (Sub) FLDBEG
0 - 15
3
31 (Sub) FLDEND
0 - 15
10
Page of 127