DOWNLOAD Panasonic PT-DZ12000U / PT-DZ12000E / PT-D12000U / PT-D12000E / PT-DW100U / PT-DW100E (serv.man2) Service Manual ↓ Size: 30.43 MB | Pages: 127 in PDF or view online for FREE

Model
PT-DZ12000U PT-DZ12000E PT-D12000U PT-D12000E PT-DW100U PT-DW100E (serv.man2)
Pages
127
Size
30.43 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / DLP BASED PROJECTOR
File
pt-dz12000u-pt-dz12000e-pt-d12000u-pt-d12000e-pt-d.pdf
Date

Panasonic PT-DZ12000U / PT-DZ12000E / PT-D12000U / PT-D12000E / PT-DW100U / PT-DW100E (serv.man2) Service Manual ▷ View online

4.3.7. Additional Function for RS-232C in PROJECTOR SETUP menu
     ·    
SIGNAL SELECTOR
ON: Sets it when an optional signal selector is connected.
OFF: Default setting
4.3.8. Additional Function for AIR FILTER CLEANING in PROJECTOR SETUP menu
     ·    
CREANING
ON: Default setting
OFF: Disables automatic cleaning operation.
4.3.9. Additional Function for INITIALIZE in PROJECTOR SETUP menu
     ·    
SHUTTER COUNTER
Initializes it when the shutter is replaced.
     ·    
CLEANING COUNTER
Initializes it when the air filter unit is replaced.
4.3.10. Addition of EXTRA OPTION
     ·    
LIGHT OUTPUT
Adjusts brightness with Dynamic Iris. It darkens as the value becomes small.
     ·    
CUT OFF
Sets whether to display each color of Red, Green and Blue.
     ·    
GAMMA SELECT
DEFAULT: Default setting
ALL: Selecting items of GAMMA SELECT in PICTURE menu increase.
     ·    
POWER ON SHUTTER
OPEN: Opens the shutter when power ON.
CLOSE: Closes the shutter when power ON.
     ·    
POWER OFF SHUTTER
OPEN: Opens the shutter when power OFF.
CLOSE: Closes the shutter when power OFF.
13
PT-DZ12000U / PT-DZ12000E / PT-D12000U / PT-D12000E / PT-DW100U / PT-DW100E
IGNORE: Does not control the shutter when power OFF.
     ·    
CINEMA FILTER
NONE: Default setting
INSTALLED: When installing the color filter that expands the color region
     ·    
AIR FILTER
NORMAL: Default setting
SPECIAL: Sets it when the smoke cut filter is installed.
     ·    
UNIFORMITY
Sets the value of color unevenness correction.
     ·    
FRONT LAMP LED
ON: Default setting
OFF: Prohibits a green lighting.
     ·    
LAMP CHANGE MUTE
ON: Turns off the projection temporarily when switching the lighting lamp.
OFF: Does not turn off the projection when switching the lighting lamp. However, a video noise might appear momentarily in the
projection.
     ·    
LENS SHIFT CALIBRATION
Calibrates the limit and the home position of the lens shift.
Execute LENS SHIFT CALIBRATION according to the procedure of the next paragraph when replacing the lens mount, LH-
Module or LV-Module.
     ·    
COOLING TIME
NORMAL: Sets all the cooling time to 240 seconds.
FAST: Default setting (Sets all the cooling time to 170 seconds.)
     ·    
MENU LOCK
ON: Sets the menu lock.
OFF: Default setting
     ·    
MENU LOCK PASSW ORD
Sets the password for the menu lock release. The default (initial password) is "AAAA".
4.3.11. Execution of LENS SHIFT CALIBRATION
 1. Enter the serviceman mode according to the section 4.1. "Setting to Serviceman Mode".
 2. Select LENS SHIFT CALIBRATION in EXTRA OPTION.
 3. Press the ENTER button. When you execute LENS SHIFT CALIBRATION, press the ENTER button again when displayed
"SURE?".
 4. The lens moves up/down/right/left, and the limit and the home position values of the shift are set again automatically.
 5. When the lens stops, re-setting is finished.
5 Self-diagnosis Display
There is a self-diagnosis display located at the side of the projector which automatically displays their details when error, warning
or others occur.
If a code is displayed in the self-diagnosis display, check the part of the cause according to the content of the code table below.
5.1. Code Table
Self-
diagnosis
display
Contents
Shutdown
Display condition
Remarks
U11
Temperature warning (IN)
Intake air temperature is the specific value or
higher.
U12
Temperature warning (OPT)
Optical module temperature is the specific
value or higher.
U13
Temperature warning (OUT)
Lamp surroundings temperature is the specific
value or higher.
U14
Low temperature warning (OPT)
Optical module temperature is less than the
specific value.
14
PT-DZ12000U / PT-DZ12000E / PT-D12000U / PT-D12000E / PT-DW100U / PT-DW100E
Self-
diagnosis
display
Contents
Shutdown
Display condition
Remarks
U15
Optical output restriction for the
projector protection
40 °C (35 °C when ALTITUDE MODE is ON) or
higher in ambient temperature at QUAD mode
U21
Temperature error (IN)
Intake air temperature is the specific value or
higher.
After turning on the power, the
shutdown processing is not
done for 2.5 minutes.
U22
Temperature error (OPT)
Optical module temperature is the specific
value or higher.
U23
Temperature error (OUT)
Lamp surroundings temperature is the specific
value or higher.
U24
Low temperature error (OPT)
*1
Optical module temperature is less than 5°C.
U41
Lamp 1 operating time warning
Lamp cumulative usage time is 1 800 hour or
longer.
LAMP monitor lights in red.
U42
Lamp 2 operating time warning
U43
Lamp 3 operating time warning
U44
Lamp 4 operating time warning
U61
Lamp 1: 2 000 hour operating time
exceeded
*2
Lamp cumulative usage time is 2 000 hour or
longer.
After turning on the lamp, it will
turn off in 10 minutes. LAMP
monitor lights in red.
U62
Lamp 2: 2 000 hour operating time
exceeded
*2
U63
Lamp 3: 2 000 hour operating time
exceeded
*2
U64
Lamp 4: 2 000 hour operating time
exceeded
*2
U51
Lamp 1 going out
*2
Lamp goes out after turning on.
LAMP monitor blinks 3 times in
red.
U52
Lamp 2 going out
*2
U53
Lamp 3 going out
*2
U54
Lamp 4 going out
*2
U51
Lamp 1 lighting failure
*2
Lamp ignition failure
LAMP monitor blinks 3 times in
red.
U52
Lamp 2 lighting failure
*2
U53
Lamp 3 lighting failure
*2
U54
Lamp 4 lighting failure
*2
U70
Air filter unit not installed
Air filter unit is not installed.
Confirms the installation when
turning on the power.
U71
Lamp 1 not installed
Lamp is not installed (The lamp memory cannot
be read.)
LAMP monitor blinks 3 times in
red.
U72
Lamp 2 not installed
U73
Lamp 3 not installed
U74
Lamp 4 not installed
U75
Special filter setting
SPECIAL has been selected on AIR FILTER in
EXTRA OPTION menu.
This display is not an error.
U81
AC power supply voltage drop
warning (less than 99 V)
AC power supply voltage drops.
U91
Lamp unit cover is not closed
Lamp unit cover is not closed for 1 second or
longer.
If the cover is not closed when
turning on the power, it does
not turn on.
H11
Thermosensor disconnected (IN)
Intake air thermosensor is disconnected.
H12
Thermosensor disconnected (OPT)
Optical module thermosensor is disconnected.
H13
Thermosensor
disconnected
(OUT)
Lamp
surroundings
thermosensor
is
disconnected.
H18
Airflow sensor disconnected
Airflow sensor is disconnected.
U04
Air filter is blocked
The air filter accumulates dust.
H01
Internal clock battery replacement
The date is before December 31, 2005 or after
January 1, 2036.
If this error occurs, the date is
reset on 00:00:00, January 1,
2006.
15
PT-DZ12000U / PT-DZ12000E / PT-D12000U / PT-D12000E / PT-DW100U / PT-DW100E
Self-
diagnosis
display
Contents
Shutdown
Display condition
Remarks
FE1
Fan error 1: P-UNIT FAN
The fan stops for 5 seconds or longer.
Power unit fan
FE2
Fan error 2: LAMP FAN 1
Lamp fan 1
FE3
Fan error 3: LAMP FAN 2
Lamp fan 2
FE4
Fan error 4: LAMP FAN 3
Lamp fan 3
FE5
Fan error 5: LAMP FAN 4
Lamp fan 4
FE6
Fan error 6: BALLAST1 FAN
Ballast fan 1
FE7
Fan error 7: BALLAST3 FAN
Ballast fan 3
FE8
Fan error 8: GB-DMD FAN
GB-DMD fan
FE9
Fan error 9: EXAUST FAN C
Exhaust fan (C)
FF0
Fan error 10: EXAUST FAN L
Exhaust fan (L)
FF1
Fan error 11: EXAUST FAN R
Exhaust fan (R)
FF2
Fan error 12: R-DMD FAN
R-DMD fan
FF3
Fan (Module) error 13: G-LIQUID
COOLING
Liquid cooling pump (G)
FF4
Fan (Module) error 14: B-LIQUID
COOLING
Liquid cooling pump (B)
FF5
Fan error 15: C-PRISM FAN
Color prism fan
FF6
Fan error 16: L-PRISM FAN
Lamp prism fan
FF7
Fan error 17: BALLAST2 FAN
Ballast fan 2
FF8
Fan error 18: BALLAST4 FAN
Ballast fan 4
FF9
Fan error 19: G-PRISM FAN
G-prism fan
F11
Shutter error
Shutter error
F12
Dynamic iris error
Dynamic iris error
F13
Air filter unit error
Air filter cleaning processing time-out
F21
2.5 V DC error
2.5 V DC error
F22
3.3 V DC error
3.3 V DC error
F23
5.0 V DC error
5.0 V DC error
F41
Lamp 1 memory error
*2
Lamp EEPROM is abnormal.
LAMP monitor blinks 3 times in
red.
F42
Lamp 2 memory error
*2
F43
Lamp 3 memory error
*2
F44
Lamp 4 memory error
*2
F61
Lamp
1
ballast
communication
error
*2
Fails in the communication with the ballast
MPU.
F62
Lamp
2
ballast
communication
error
*2
F63
Lamp
3
ballast
communication
error
*2
F64
Lamp
4
ballast
communication
error
*2
F80
Resize IC setting error
No response from the resize IC
F81
FM-R test fail
RDRAM test error
F82
FM-G tset fail
F83
FM-B test fail
F91
FPGA1 configuration error
A-P.C.Board is abnormal.
F92
FPGA2/3 configuration error
FH-Module is abnormal.
WF-Module is abnormal.
F93
Flash ROM error
The circuit around CPU on A-P.C.Board is
abnormal.
F94
RAM error
F95
FPGA expansion error
F96
Lens shift error
The
circuit for lens position detection
is
abnormal.
F97
WF-Module (GEOMETRY)
communication error
No response from the geometry IC
Displays in
PT-DZ12000*/DW100* only.
Explanatory notes of shutdown column
Shutdown occurs.
Shutdown does not occur.
*1 Shutdown occurs only when starting. (Shutdown does not occur even if the temperature becomes less than 5°C during normal
operating.)
*2 Shutdown occurs when all lamps cannot be lit.
5.2. Comparison Table of Self-diagnosis Display and Code
Self-diagnosis
display
Code
Self-diagnosis
display
Code
U11
00000000 00000000 00000000 00000001
FE4
00000000 00000000 00080000 00000000
16
PT-DZ12000U / PT-DZ12000E / PT-D12000U / PT-D12000E / PT-DW100U / PT-DW100E
Page of 127
Display