DOWNLOAD Panasonic PT-CW240U / PT-CW240E / PT-CW240EA / PT-CW330U / PT-CW330E / PT-CW330EA / PT-CX300U / PT-CX300E / PT-CX300EA / PT-CW241RU / PT-CW241RE / PT-CW241REA / PT-CW331RU / PT-CW331RE / PT-CW331REA / PT-CX301RU / PT-CX301RE / PT-CX301REA (serv.man2) Service Manual ↓ Size: 16.39 MB | Pages: 92 in PDF or view online for FREE

Model
PT-CW240U PT-CW240E PT-CW240EA PT-CW330U PT-CW330E PT-CW330EA PT-CX300U PT-CX300E PT-CX300EA PT-CW241RU PT-CW241RE PT-CW241REA PT-CW331RU PT-CW331RE PT-CW331REA PT-CX301RU PT-CX301RE PT-CX301REA (serv.man2)
Pages
92
Size
16.39 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / DLP BASED PROJECTOR
File
pt-cw240u-pt-cw240e-pt-cw240ea-pt-cw330u-pt-cw330e.pdf
Date

Panasonic PT-CW240U / PT-CW240E / PT-CW240EA / PT-CW330U / PT-CW330E / PT-CW330EA / PT-CX300U / PT-CX300E / PT-CX300EA / PT-CW241RU / PT-CW241RE / PT-CW241REA / PT-CW331RU / PT-CW331RE / PT-CW331REA / PT-CX301RU / PT-CX301RE / PT-CX301REA (serv.man2) Service Manual ▷ View online

PT-CW240/PT-CX300/PT-CW330/PT-CW241R/PT-CX301R/PT-CW331R
5-7
5-2: MCU Firmware Upgrade Procedure
5-2-1 Equipment Needed
Software:
- SMAT PICC Programming Applucation (RS232.EXE)
- "SMARTmpu_v1.02_setup.exe" must be run to setup the software.
- xxx_xxx_xxx.hex 
Hardware: 
-  Projector 
-  Power Cord: H420010BG001 (US Type)
                        H4200120G011 (EU Type)
                        H4281004G001 (CH Type)
- RS232 Cable :H4283C07G002 (RS-232 9 Pin Cable (pin to pin, F-M))
- PC or Laptop
5-2-2 MCU  Firmware Upgrade Procedure
1. Set up
- Hold on "MENU" button and plug in the
      power cord. 
- About 4 seconds, the Power LED will light  
orange ,the Lamp LED and Temp LED will  
       light red ,get into FW Download mode.
- Release the "MENU" button.
    -  Connect projector with RS232C cable to 
PC.
Note:  - The system fan and the lamp will not  
operate. 
2.
Execute  the  "SMART  PICC  Programming
Application (RS232
.exe)" file.
PT-CW240/PT-CX300/PT-CW330/PT-CW241R/PT-CX301R/PT-CW331R
5-8
RS232 cable
Power cord
SMART PICC Programming
Application
PT-CW240/PT-CX300/PT-CW330/PT-CW241R/PT-CX301R/PT-CW331R
5-9
3. Program settings
- Make sure the settings are as below:
1) PORT: Check the COM port is “COM 3”
(Select the COM port which you are
             using).    
       2) Baudrate :19200
       3) Program : NON-ECHO
    
         
4. Click the “Load” button.
5. Choose “*.HEX” file.
- Click "Open".
PT-CW240/PT-CX300/PT-CW330/PT-CW241R/PT-CX301R/PT-CW331R
5-10
6. Click the “Rescue Program” button.
    
7. Click “OK” .
Page of 92
Display

Click on the first or last page to see other PT-CW240U / PT-CW240E / PT-CW240EA / PT-CW330U / PT-CW330E / PT-CW330EA / PT-CX300U / PT-CX300E / PT-CX300EA / PT-CW241RU / PT-CW241RE / PT-CW241REA / PT-CW331RU / PT-CW331RE / PT-CW331REA / PT-CX301RU / PT-CX301RE / PT-CX301REA (serv.man2) service manuals if exist.