Panasonic DP-1520P / DP-1820P / DP-1820E Service Manual ▷ View online

37
JUN 2004
Ver. 1.0
DP-1520P/1820P/1820E
2.4.
Preventive Maintenance Check List
The chart outlined below is a general guideline for maintenance. 
No.
Mechanical Parts
Ref. 
No.
Cleaning
Replacement/Adjustment
Ref. 
Counter
Cycle 
(Sheet)
Method
Cycle 
(Sheet)
Procedure
i-ADF Unit
1 ADF Roller
2314
60K
Alcohol
120K
Refer to 
2.2.1. of the 
Service 
Manual
F7-08
2 Pre Feed Roller
2018
60K
Alcohol
120K
3 Separation Roller
2509
60K
Alcohol
120K
4 Torque Limiter 
Bushing
2510
60K
Alcohol
120K
5 Torque Limiter 
Spring
2511
60K
Alcohol
120K
ADF Unit
6
Exit 1 Roller
1812
60K
Alcohol
-
Refer to 
2.2.2. of the 
Service 
Manual
F7-08
7
White Sheet
1814
60K
Alcohol
-
8
Feed Roller
2010
60K
Alcohol
-
9
Pre Feed Roller
2018
60K
Alcohol
120K
10 Separation Rubber
2024
-
-
60K
11 Paper Feed Roller
2001
60K
Alcohol
120K
12 Scanning Pad
1822
60K
Dry soft cloth
-
Scanner Unit
13 Mirror 1
415
60K
-
-
Refer to 
2.2.4. of the 
Service 
Manual
F7-04
14 Mirror 2
421
60K
-
-
15 Platen (L) Glass
106
60K
-
-
16 Scanning (S) Glass
110
60K
-
-
2nd, 3rd & 4th Paper Trays
17 Pickup Roller
619
60K
Alcohol
120K
Refer to 
2.2.10. of the 
Service 
Manual
F7-12/-13/-
14/-15
18 Separation Roller
629
60K
Alcohol
120K
19 Torque Limiter 1
690
-
-
120K
20 Feed Roller
623
60K
Alcohol
120K
21 Intermediate Roller
3104
60K
Alcohol
-
Sheet Bypass
22 Feed Roller
689
60K
Alcohol
120K
Refer to 
2.2.9. of the 
Service 
Manual
F7-11
23 Separation Roller
658
60K
Alcohol
120K
24 Torque Limiter 2
691
-
-
120K
25 Registration Roller
601
60K
-
-
Bias Transfer Unit
26 Bias Transfer Roller 
(BTR)
711
60K
Dry soft cloth
120K
Refer to 
2.2.8. of the 
Service 
Manual
F7-02
27 Duplex Feed Roller
735
60K
-
Process Unit
-
Developer
-
-
-
60K
Refer to 
2.2.5. of the 
Service 
Manual
F7-10
28 OPC Drum
1403
-
-
60K
F7-06
38
JUN 2004
Ver. 1.0
DP-1520P/1820P/1820E
Note:
1. Wet Cloth represents a soft cloth saturated with water.
For stubborn toner accumulation, wipe with a soft cloth saturated with Isopropyl Alcohol first, then 
follow up with a soft cloth saturated with water.
2. The Maintenance Cycle is based on the Counter Information for each individual module. 
To verify the counter information, print the Total Counter List using the Service Mode: F7 - Electronic 
Counter - 00 (List Print).
3. Cleaning, Replacement and Adjustment Cycle (Sheet) are based on using Panasonic's recommended 
standard paper and supplies. These cycles may vary with the kind of paper used, Paper size, 
orientation, print duty, continuous/interval print and/or ambient conditions.
• Total Counter View Mode on the LCD
The Total Counter can be displayed on the Panel Display by pressing "COPY SIZE" and "PAPER TRAY" 
keys simultaneously in Standby mode for quick reference.
• LCD Contrast Adjustment
Press holding the “CLEAR” key and press “ORIGINAL SIZE” key for Lighter or “COPY SIZE” key for 
Darker.
29 Charge Corona Case 1444
60K
-
-
Refer to 
2.2.5. of the 
Service 
Manual
F7-07
30 Charge Wire
1443
10K
By Customer
-
60K
31 Cleaning Blade
1408
-
-
60K
32 Front Cleaning Felt
1410
-
-
60K
33 Rear Cleaning Felt
1411
-
-
60K
34 Cleaning Sponge
1412
-
-
60K
35 Sheet Scoop
1415
-
-
60K
Fuser Unit
36 Fuser Roller
1115
60K
Alcohol
120K
Refer to 
2.2.6. of the 
Service 
Manual
F7-02
37 Pressure Roller
1021
60K
Alcohol
240K
38 Fuser Roller Busing
1114
-
-
120K
39 Pressure Roller 
Busing
1020
-
-
240K
40 Thermistor 
Assembly
1125
60K
Dry soft cloth
120K
41 Fuser Lamp
1116
-
-
240K
42 Separator
1109
60K
Alcohol
120K
43 Exit 2 Roller
1104
60K
-
-
Main Unit
44 Ozone Filter
825
-
-
240K
Refer to 
2.2.13. of the 
Service 
Manual
F7-02
45 Toner Spill Tray
1202
60K
-
-
No.
Mechanical Parts
Ref. 
No.
Cleaning
Replacement/Adjustment
Ref. 
Counter
Cycle 
(Sheet)
Method
Cycle 
(Sheet)
Procedure
TOTAL COUNTER
                 
1234
39
JUN 2004
Ver. 1.0
DP-1520P/1820P/1820E
2.5.
Resetting the P/M (Preventive Maintenance) Counter
When the machine reaches the preset P/M Cycle, it will show "Call for P/M" or "Replace The Toner Waste 
Container" on the LCD Display. The PM Counter can be reset by following the procedures below.
2.5.1.
"Call for P/M" (Default: 120K) 
1. Perform the P/M (Preventive Maintenance). Refer to Section 2.3 and 2.4.
2. Press “FUNCTION”, “ORIGINAL SIZE”, and “3” keys sequentially to enter the Service Mode.
3. Enter the Copy Service Mode F5-70 (PM Cycle) and change to the desired value.
4. Press “FUNCTION” and “CLEAR” keys simultaneously to exit the Service Mode.
2.5.2.
"Call for P/M ADF" (Default: Not Set)
1. Perform the P/M (Preventive Maintenance). Refer to Section 2.3 and 2.4.
2. Press “FUNCTION”, “ORIGINAL SIZE”, and “3” keys sequentially to enter the Service Mode.
3. Enter the Copy Service Mode F5-87 (ADF PM Cycle) and change to the desired value.
4. Press “FUNCTION” and “CLEAR” keys simultaneously to exit the Service Mode.
2.5.3.
U14 "Replace The Toner Waste Container"
A. Blinking Maintenance and Toner Waste Container Indicators
Upon detecting that the Toner Waste Container is full, the machine will complete the current job, and 
stop operating. 
A blinking Maintenance and Toner Waste Container Indicators will appear on the display. 
To continue using the machine temporarily while waiting for the Service Technician, press any key 
(up to 100 additional copies can be made).
B. Steady Maintenance and Toner Waste Container Indicators
Upon reaching the 100 copies, the machine stops and will not allow further operation until the Toner 
Waste Container is replaced. 
Replace the Toner Waste Container. (Refer to Section 2.2.5. of the Service Manual)
40
JUN 2004
Ver. 1.0
DP-1520P/1820P/1820E
2.6.
Lubrication Point List
This information is used for routine Preventive Maintenance (PM) calls to ensure the highest degree of 
reliability. Inspect the following areas and lubricate as required. The inspection interval is usually 120K 
copies or more, however the interval may be reduced due to environmental conditions.
Mechanical Parts
Ref. 
No.
Grease
Lubrication Point
Automatic Duplex Unit
Pinch Timing Roller
712
KS-660
Bias Transfer 
Bushing
709
Page of 127
Display