Panasonic TH-80LF50ER Service Manual ▷ View online
Self Check
1. Self check is used to automatically check the bus line controlled circuit of the LCD display.
2. To get into the Self check mode, press the volume down button on the customer controls at the top of the set,
2. To get into the Self check mode, press the volume down button on the customer controls at the top of the set,
at the same time pressing the OFF TIMER button on the remote control, and the screen will show.
If the IIC ports have been checked and found to be incorret, or not located then “- -” will appear in place “OK”
“0A” in the lie of the “PTCP” means the number of blinks of the Power LED is 10. (Reference_Power LED blinking timing
chart)
“H09” in the line of the “PTCP” is the error code
To exit the CAT mode switch off the main power.
Note:
The line of the “PTCP” display when you get into the Self check mode for first time only after the Power LED blinks.
IIC1 IIC2
A IC4504 OK H64 DS IC3120 OK H8C
IC4701 OK HA0
IC4201 OK HB0
IC4506 OK H92
ADC Adjust OK
EDID VERIFY OK
MONITOR-MCU 1.0200LF50 OK
MONITER-EEPROM 00.50 20 8804
MONITER-SUB MCU 00.50
MONITER-EEPROM 00.50 20 8804
MONITER-SUB MCU 00.50
17
Power LED blinking timing chart
1. Subject
Information of LED Flashing timing chart.
2. Contents
When abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the
defective block can be identified by number of blinking of the Power LED on the front panel of the unit.
defective block can be identified by number of blinking of the Power LED on the front panel of the unit.
Blinking times
Name
PTCT
indication
Detect item
Detect pin
2
POWER SOS
02 H09
POWER PCB
*PWR24V, PWR15V, PWR5V Low level detect
*PWR24V, PWR15V, PWR5V Low level detect
SUB CPU Pin No.40
(POWER_FAIL1)
(POWER_FAIL1)
4
PANEL12V
SOS
SOS
04 H09
*PANEL12V Low level detect
SUB CPU Pin No.51
(POWER_FAIL3)
(POWER_FAIL3)
10 DS_SOS
0A
H09
DS PCB
*SLOT3.3V,SLOT5V.SLOT9V Low level detect
*SLOT3.3V,SLOT5V.SLOT9V High level detect
*FunctionBoard_SOS
*SLOT3.3V,SLOT5V.SLOT9V Low level detect
*SLOT3.3V,SLOT5V.SLOT9V High level detect
*FunctionBoard_SOS
SUB CPU Pin No.42
13
REGULATOR
SOS
SOS
0D H09
A PCB
*D3.3V,DDR1.8V,H3.3V,AS1.8V Low level detect
*D3.3V,DDR1.8V,H3.3V,AS1.8V Low level detect
SUB CPU Pin No.41
(POWER_FAIL2)
(POWER_FAIL2)
18
Adjustment Method
RGB white balance adjustment
Instrument Name
Connect to
Remarks
INTERNAL PATTERN – 100% WHITE
Color analyzer
( Minolta CA-210 or equivalent )
( Minolta CA-210 or equivalent )
Panel surface
Picture menu: STANDARD
User setting: Normal
except PICTURE: max 30
User setting: Normal
except PICTURE: max 30
Procedure Remarks
[Conditions]
Make sure the front panel to be used on the final set is fitted.
Center position
[Adjustment]
1. Set COMPONENT / RGB-IN SELECT to COMPONENT
2. Select the IIC mode “LCD Drive Adj.” item.
3. Check that the color temperature is “MID”
4. Output a white balance pattern.
5. Touch the signal receiver of color analyzer to the highlight window’s center.
6. Fix G drive at 30h and adjust B drive and R drive so x, y become the “Colour
2. Select the IIC mode “LCD Drive Adj.” item.
3. Check that the color temperature is “MID”
4. Output a white balance pattern.
5. Touch the signal receiver of color analyzer to the highlight window’s center.
6. Fix G drive at 30h and adjust B drive and R drive so x, y become the “Colour
temperature NORMAL(Mid) in the below table.
7. At least fix one of the RGB’s drive data at 30h and adjust the others drive so x/y
(The highest RGB’s drive value is 30h)
Table W/B adjustment values
Color Temperature
x
y
NORMAL(Mid) 0.288
0.296
Adjustment target
Hi-light. X ± 0.005 y ± 0.005
Hi-light is target of the number at drive adjustment in the hi–light windows.
Therefore, it is not target of the hi-light number at after adjustment white balance.
Note :
Hi-light. X ± 0.005 y ± 0.005
Hi-light is target of the number at drive adjustment in the hi–light windows.
Therefore, it is not target of the hi-light number at after adjustment white balance.
Note :
Internal signal: STANDARD
Aspect: Full
Picture setting: Standard
Backlight: 100(Default)
Aspect: Full
Picture setting: Standard
Backlight: 100(Default)
“7“ key: color temperature select
Color temperature – Normal
(Mid.)
(Mid.)
Let the panel stand for more than 3
hours at more than 20
C.
Basically perform adjustment in the
ambient environment of room
temperature more than 20
ambient environment of room
temperature more than 20
C.
The aging time is more than20 min
at above room temperature.
at above room temperature.
Change DRIVE(R,G,B) by UP/DOWN buttons on the remote control
+
-
Change Value Register by VOL+/- buttons on the remote control
19
HDMI1
JK4003
DVI IN JK4002
A-BOARD
A13
DS-BOARD
DS13
LCD PANEL
P-UNIT
P6
MAIN IN
A1
P1
P3
PC JK4001
YUV
VIDEO IN
RCA
JK4004
V1-BOARD
A22
V2-BOARD
V22
A5
P5
A4
P4
KEY
RM,SN
A7
HX7
HX-BOARD
DS2
DS3
A8
HX8
JK3503
AUDIO IN
RCA
JK3501
RS-232C
IN
JK3506
AUDIO
OUT
JK3504
JK3505
AUDIO IN
PC or DVI
RS-232C
OUT
JK2701
JK4006
DVI OUT
ETHERNET
A10
DS10
A40
SERVICE
A48
SERVICE
Wiring Diagram
CN101
CN1
HX11
V11
20
Click on the first or last page to see other TH-80LF50ER service manuals if exist.