DOWNLOAD Panasonic TH-50PH10BK / TH-50PH10BS / TH-50PH10EK / TH-50PH10ES (serv.man2) Service Manual ↓ Size: 21.7 MB | Pages: 127 in PDF or view online for FREE

Model
TH-50PH10BK TH-50PH10BS TH-50PH10EK TH-50PH10ES (serv.man2)
Pages
127
Size
21.7 MB
Type
PDF
Document
Service Manual
Brand
Device
Plasma / GPH10D CHASSIS
File
th-50ph10bk-th-50ph10bs-th-50ph10ek-th-50ph10es-sm.pdf
Date

Panasonic TH-50PH10BK / TH-50PH10BS / TH-50PH10EK / TH-50PH10ES (serv.man2) Service Manual ▷ View online

8 Adjustment Procedure
8.1. Driver Set-up
8.1.1. Item / Preparation
 1. Set Aging pattern 0 (Vset adjustment pattern) by IIC mode.
 2. Set the picture adjustment items as follows.
     ·    Picture menu : Standard
     ·    Color temperature : Normal
     ·    Picture : 25
     ·    Aspect : Full
8.1.2. Adjustments
Adjust driver section voltages referring the panel data label.
Caution
 1. First perform Vsus voltage adjustment.
 2. Confirmation of Vscn voltage should be performed after confirmation of Vad voltage adjustment.
When Vad = -105V, Voltage of Vscn is 35V ± 4V.
21
TH-50PH10BK / TH-50PH10BS / TH-50PH10EK / TH-50PH10ES
8.2. Initialization Pulse Adjust
 1. Input the white signal to plasma video input.
 2. Set the picture adjustment items as follows.
     ·    Picture menu : Standard
     ·    Color temperature : Normal
     ·    Picture : 25
     ·    Aspect : Full
 3. Connect Oscilloscope to TPSC1 (T2) and sdjust VR6602 for 185 ± 10µ Sec.
Test Point
Volume
Level
T2
TPSC1 (SC)
VR6602 (SC)
185 ± 10µ Sec
8.3. P.C.B. (Print Circuit Board) Remove
8.3.1. Caution
1. To remove P.C.B., wait 1 minute after power was off for discharge from electrolysis capacitors.
8.3.2. Quick adjustment after P.C.B. Remove
P.C.B.
Name
Test Point
Voltage
Volume
Remarks
P Board
Vsus
TPVSUS (SS)
Vsus ± 2V
VR251 (P)
*
SC Board
Vad
TPVAD
-105V ± 1V
VR6600 (SC)
Vbk
TPVBK
155V ± 1V
VR6604 (SC)
SS Board
Ve
TPVE
Ve ± 1V
VR6000 (SS)
*
DS Board
White balance, Pedestal and Sub brightness for NTSC, PAL, HD, PC and 625i signals
DN Board
Set Market Select Number to correct destination by Ms mode (See chap. 9.1.4)
*See the Panel label.
Caution
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
22
TH-50PH10BK / TH-50PH10BS / TH-50PH10EK / TH-50PH10ES
8.4. Adjustment Volume Location
8.5. Test Point Location
23
TH-50PH10BK / TH-50PH10BS / TH-50PH10EK / TH-50PH10ES
9 Service mode
9.1. CAT (Computer Aided Test) mode
To exit the CAT mode, access the ID mode and switch off the main power.
9.1.1. IIC mode
Select the IIC mode by Up/Down button on the remote control at the front page of CAT mode and then press the Action button
on the remote control.
Subject and item are mentioned on “IIC mode structure”.
To exit the IIC mode, press the R button on the remote control.
9.1.2. CD mode
Select the CD mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button
on the remote control more than 5 seconds.
24
TH-50PH10BK / TH-50PH10BS / TH-50PH10EK / TH-50PH10ES
Page of 127
Display

Click on the first or last page to see other TH-50PH10BK / TH-50PH10BS / TH-50PH10EK / TH-50PH10ES (serv.man2) service manuals if exist.