DOWNLOAD Panasonic TH-37PR10B / TH-37PR10E / TH-42PR10B / TH-42PR10E Service Manual ↓ Size: 31.53 MB | Pages: 127 in PDF or view online for FREE

Model
TH-37PR10B TH-37PR10E TH-42PR10B TH-42PR10E
Pages
127
Size
31.53 MB
Type
PDF
Document
Service Manual
Brand
Device
Plasma / GPH10D CHASSIS
File
th-37pr10b-th-37pr10e-th-42pr10b-th-42pr10e.pdf
Date

Panasonic TH-37PR10B / TH-37PR10E / TH-42PR10B / TH-42PR10E Service Manual ▷ View online

11.3. Power control adjustment
Instrument Name
Connection
Remarks
  · PC (RGB) signal generator
(Leader: VGA/No.9 signal)
  · Wattmeter
  · PC input
  · Connect the AC power of the
adjustment set to the wattmeter.
Set “RGB” at ‘COMPONENT/RGB-IN
SELECT’ in Setup Menu.
Procedure
Remarks
[condition]
  · Make sure the set is aged for 30 minutes or more before adjustment.
  · Voltage 120V 50/60Hz (variation within 1%)
  · Volume at minimum and screen size at full
  · PC input and picture menu at normalized Dynamic
 1. 
Connect the set’s AC power to the wattmeter.
 2. 
Receive the VGA No.9 signal from Leader.
 3. 
Select the PWRCTL item in Panel APL/ABL in the IIC mode.
 4. 
Adjust PWRCTL so the set´s power consumption is description below.
Adjust to shift large to small for DAC.
Factory adjustment with OSD
37" 272 0 / -10W
42" 320 0 / -10W
No.9 Signal
Top half: Full color bar
Bottom half: Horizontal 16 steps bar
Notes:
 1. 
When passing through factory
adjustment mode, the power few
watts which goes down is the
consideration being completed.
 2. 
Adjust the large number for DAC
when they have 2 adjustment
points.
45
TH-37PR10B / TH-37PR10E / TH-42PR10B / TH-42PR10E
12.1.1. Display Indication
 1. Self-check is used to automatically check the bus line
controlled circuit of the Plasma display.
 2. To get into the Self-check mode, press the volume down
button on the customer controls at the bottom of the set, at
the same time pressing the OFF-TIMER button on the
remote control, and the screen will show:-
If the CCU ports have been checked and found to be incorrect
Or not located then " - - " will appear in place of " OK "
“ 01 “ in the line of the “ PTCT ” means the number of blinks of
the Power LED is 1. (Refer to 12.1.2)
“ H09 “ in the line of the “ PTCT ” is the error code.
Note:
The line of the “ PTCT ” displays when you get into the Self-
check mode for the first time only after the Power LED
blinks.
12 Trouble shooting guide
12.1. Self Check
12.1.2. Power LED Blinking timing chart
 1. Subject
Information of LED Blinking timing chart.
 2. Contents
When an abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the
defective block can be identified by the number of blinks of the Power LED on the front panel of the unit.
46
TH-37PR10B / TH-37PR10E / TH-42PR10B / TH-42PR10E
12.2. No Power
First check point
There are following 3 states of No Power indication by power LED.
 1. No lit.
 2. Green is lit then turns red blinking a few seconds later.
 3. Only red is lit.
12.3. No Picture
47
TH-37PR10B / TH-37PR10E / TH-42PR10B / TH-42PR10E
12.4. Local screen failure
Plasma display may have local area failure on the screen. Fig - 1 is the possible defect P.C.B. for each local area.
Fig - 1
48
TH-37PR10B / TH-37PR10E / TH-42PR10B / TH-42PR10E
Page of 127
Display

Click on the first or last page to see other TH-37PR10B / TH-37PR10E / TH-42PR10B / TH-42PR10E service manuals if exist.