DOWNLOAD Panasonic KX-TDA620BX Service Manual ↓ Size: 3.43 MB | Pages: 97 in PDF or view online for FREE

Model
KX-TDA620BX
Pages
97
Size
3.43 MB
Type
PDF
Document
Service Manual
Brand
Device
PBX / HYBRID IP-PBX
File
kx-tda620bx.pdf
Date

Panasonic KX-TDA620BX Service Manual ▷ View online

3 CAUTION
3.1. NOTE
When you note the serial number, write down all of the 11 digits.
The serial number may be found on the label affixed to the bottom of the unit.
3.2. SAFETY PRECAUTIONS
 1. Before servicing, unplug the power cord to prevent an electric shock.
 2. When replacing parts, use only the manufacturer´s recommended components for safety.
 3. Check the condition of the power cord. Replace if wear or damage is evident.
 4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
 5. Before returning the serviced equipment to the customer, be sure to perform the following insulation resistance test to prevent
the customer from being exposed to shock hazards.
3.3. INSULATION RESISTANCE TEST
 1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
 2. Turn on the power switch.
 3. Measure the resistance value with ohmmeter between the jumpered AC plug and each exposed metal cabinet part, such as
screw threads, control shafts, handle brackets, etc.
Note:
Some exposed parts may be isolated from the chassis by design. These will read infinity.
 4. If the measurement is outside the specified limits, there is a possibility of shock hazard. The equipment should be repaired and
rechecked before it is returned to the customer.
3.4. BATTERY CAUTION
 1. Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the manufacturer’s Instructions.
 2. The lithium battery is a critical component (type No.CR23541). Please observe for the proper polarity and the exact location
when replacing it and soldering the replacement lithium battery in.
3.5. CAUTION
The power socket wall outlet should be located near this equipment and be easily accessible.
5
KX-TDA620BX
4 SPECIFICATIONS
4.1. GENERAL DESCRIPTION
Control Bus
Original bus (16 bit, 8 MHz,10 megabytes per second)
Communication Bus
H.100 bus conformity (1024 time slot)
Switching
Distributed Switching
Power Input
PSU-M
100 V AC to 130 V AC, 2.5 A/200 V AC to 240 V AC, 1.4 A, 50 Hz/60 Hz
PSU-L
100 V AC to 130 V AC, 5.1 A/200 V AC to 240 V AC, 2.55 A, 50 Hz/60 Hz
External Battery
+36 V DC (+12 V DC x 3, recommended maximum current per shelf is 28 Ah or lower)
Maximum Power Failure Tolerance
300 ms (without using backup battery)
Memory Backup Duration
7 years
Dialling
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Trunk Loop Limit
1600
Ω maximum
Operating
Environment
Temperature
0 °C to 40 °C
Humidity
10%to 90% (non-condensing)
Conference Call Trunk (per shelf)
From 10 x 3-party conference call to 4 x 8-party conference call
Extension Connection Cable
SLT
1 pair wire (T, R)
DPT
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
APT
2-pair wire (T, R, D1, D2)
PT-interface CS
1-pair wire (D1, D2)
DSS Consoles and Add-on Key Module
1-pair wire (D1, D2)
Dimension
Expansion Shelf
430 mm (W) x 415 mm (H) x 270 mm (D)
(17 1/5 in x 16 3/5 in x 10 4/5 in)
Weight (when fully mounted) Expansion Shelf
Under 16 kg (35.2 lb)
4.2. CHARACTERISTICS
Terminal Equipment Loop Limit
     • 
• 
• 
• PT: KX-T7600 series DPT: 90 Ω; all other DPTs/APTs: 40 Ω
     • 
• 
• 
• SLT: 600 Ω including set
     • 
• 
• 
• Doorphone: 20 Ω
     • 
• 
• 
• CS: 130 Ω; PT-interface CS: 65 Ω
Minimum Leakage Resistance
15000
Ω maximum
Maximum Number of Extension
Instruments per Line
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
3 by Digital eXtra Device Port connection of 2 DPTs and an SLT
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Trunk Loop Limit
1600
Ω maximum
Hookswitch Flash/Recall Timing Range
24 ms to 2032 ms
BRI Cards Internal ISDN Mode
Supply Voltage: 40 V
Power Supply (BRI4): 4.5 W per 1 line, 10 W per 4 lines
Power Supply (BRI8): 4.5 W per 1 line, 20 W per 8 lines
Power Supply Method: Phantom Power Supply
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
External Relay Current Limit
24 V DC/30 V AC, 1 A maximum
External Sensor Current Limit
Power to the external sensor is provided from the EIO4 card and must be grounded through
the EIO4 card. The Hybrid IP-PBX detects input from the sensor when the signal is under
100
6
KX-TDA620BX
4.3. SYSTEM CONSTRUCTION
4.3.1. Expansion System
Expansion Shelf
The Expansion Shelf contains a BUS-S card for controlling the Hybrid IP-PBX. To use the Expansion system, install a power
supply unit (PSU) in the PSU Slot and optional service cards in Free Slots.
Construction of the Expansion Shelf
7
KX-TDA620BX
2-shelf System
Expanded system (Basic Shelf + 1 Expansion Shelf). Expansion Shelf 1 is mounted on the Basic Shelf.
Note
If you are installing a 2-shelf system in an area prone to earthquakes, make sure to fix the system to the wall using the wall
brackets (supplied with an optional Mounting Kit).
3-shelf System (Tower Type)
Expanded system (Basic Shelf + 2 Expansion Shelves). Expansion Shelves 1 and 2 are mounted on the Basic Shelf. A
Mounting Kit is required for the 3-shelf system.
8
KX-TDA620BX
Page of 97
Display

Click on the first or last page to see other KX-TDA620BX service manuals if exist.