3 CAUTION
3.1. NOTE
When you note the serial number, write down all of the 11 digits.
The serial number may be found on the label affixed to the bottom of the unit.
3.2. SAFETY PRECAUTIONS
 1. Before servicing, unplug the power cord to prevent an electric shock.
 2. When replacing parts, use only the manufacturer´s recommended components for safety.
 3. Check the condition of the power cord. Replace if wear or damage is evident.
 4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
 5. Before returning the serviced equipment to the customer, be sure to perform the following insulation resistance test to prevent
the customer from being exposed to shock hazards.
3.3. INSULATION RESISTANCE TEST
 1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
 2. Turn on the power switch.
 3. Measure the resistance value with ohmmeter between the jumpered AC plug and each exposed metal cabinet part, such as
screw threads, control shafts, handle brackets, etc.
Note:
Some exposed parts may be isolated from the chassis by design. These will read infinity.
 4. If the measurement is outside the specified limits, there is a possibility of shock hazard. The equipment should be repaired and
rechecked before it is returned to the customer.
3.4. BATTERY CAUTION
 1. Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the manufacturer’s Instructions.
 2. The lithium battery is a critical component (type No.CR23541). Please observe for the proper polarity and the exact location
when replacing it and soldering the replacement lithium battery in.
3.5. CAUTION
The power socket wall outlet should be located near this equipment and be easily accessible.
5
KX-TDA200UA
4 SPECIFICATIONS
4.1. GENERAL DESCRIPTION
Control Bus
Original bus (16 bit, 8 MHz,10 megabytes per second)
Communication Bus
H.100 bus conformity (1024 time slot)
Switching
Non Blocking Distributed Time Switch
Power Input
PSU-M
(KX-TDA0104)
100 V AC to 130 V AC/200 V AC to 240 V AC, 2.5 A/1.4 A, 50 Hz/60 Hz
PSU-L
(KX-TDA0103)
100 V AC to 130 V AC/200 V AC to 240 V AC,5.1 A/2.55 A, 50 Hz/60 Hz
External Battery
+36 V DC (+12 V DC x 3, battery capacity of 28 Ah or below recommended for 1 external
battery)
Maximum Power Failure Tolerance
300 ms (without using backup battery)
Memory Backup Duration
7 years
Dialling
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Trunk Loop Limit
1600
Ω maximum
Operating
Environment
Temperature
0 °C to 40 °C
Humidity
10%to 90% (non condensing)
Conference Call Trunk
From 10 x 3-party conference call to 4 x 8-party conference call
Music on Hold (MOH)
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Paging
Internal
Level Control: -6 dB to +3 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface Port
RS-232C
1 (max 115.2 kbps)
USB
1
Extension Connection Cable
SLT
1 pair wire (T, R)
DPT
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
APT
2-pair wire (T, R, D1, D2)
PT-interface CS
1-pair wire (D1, D2)
DSS Consoles and Add-on Key Module
1-pair wire (D1, D2)
Dimension
KX-TDA200
430 mm (W) x 415 mm (H) x 270 mm (D)
(17 1/5 in x 16 3/5 in x 10 4/5 in)
Weight (when fully mounted) KX-TDA200
Under 16 kg (35.2 lb)
4.2. CHARACTERISTICS
Terminal Equipment Loop Limit
     • 
• 
• 
• PT: KX-T7600 series: 90 Ω; all other DPTs/APTs: 40 Ω
     • 
• 
• 
• SLT: 600 Ω including set
     • 
• 
• 
• Doorphone: 20 Ω
     • 
• 
• 
• CS: 130 Ω; PT-interface CS: 65 Ω
Minimum Leakage Resistance
15000
Ω maximum
Maximum Number of Extension
Instruments per Line
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
3 by Digital eXtra Device Port connection of two DPTs and an SLT
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Trunk Loop Limit
1600
Ω maximum
Hookswitch Flash/Recall Timing Range
24 ms to 2032 ms
BRI Cards Internal ISDN Mode
Supply Voltage: 40 V
Power Supply: 4.5 W per 1 line, 10 W per 4 lines (BRI4)
4.5 W per 1 line, 20 W per 8 lines (BRI8)
Power Supply Method: Phantom Power Supply
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
External Relay Current Limit
24 V DC/30 V AC, 1 A maximum
External Sensor Current Limit
Power to the external sensor is provided from the EIO4 card and must be grounded through
the EIO4 card. The main unit (Hybrid IP-PBX) detects input from the sensor when the signal
is under 100
Ω.
Paging Terminal Impedance
600
MOH (Music on Hold) Terminal Impedance
10000
6
KX-TDA200UA
4.3. SYSTEM CAPACITY
4.3.1. Maximum Trunk nd Extension Cards
The following number of trunk and extension cards can be installed in the Hybrid IP-PBX for expansion.
Card Type
KX-TDA200
Trunk Card *1
8
Extension Card
8
Total
10
*1 One T1, E1, PRI30, PRI23, or IP-GW4 card counts as 2 cards. However, one IP-GW4E card counts as 1 card.
Note:
     • 
• 
• 
• For each card, a maximum number that can be installed in the main unit (Hybrid IP-PBX) is listed in "Installation Manual".
     • 
• 
• 
• Any card that exceeds the capacity of the main unit (Hybrid IP-PBX) will be ignored.
     • 
• 
• 
• When the main unit (Hybrid IP-PBX) starts up with an invalid configuration, some cards will be ignored.
4.3.2. Maximum Terminal Equipment
The following number of terminal equipment can be supported by the main unit (Hybrid IP-PBX). For how to count the total
number of items of equipment to be connected, refer to "MEC Card Calculation".
Terminal Equipment Type
KX-TDA200
Without MEC Card
With MEC Card
Telephone *1
176
304
SLT, APT, DPT and IP-PT
128
256
SLT
128
128
APT/DPT
128
256
IP-PT
128
128
DSS console
8
CS
32
PS
128
Voice Processing System (VPS)
2
Doorphone
16
Door Opener
16
External Sensor
16
External Relay
16
Add-on Key Module
128
256
USB Module
128
*1 A single "T1-OPX (Off Premise Extension) port" or "BRI/PRI extension port" is counted as a wired telephone.
MEC Card Calculation
Calculate the MEC figure from the type and total number of items of equipment to be connected. If the MEC figure exceeds 128,
you need to install an MEC card.
Equipment Type
MEC Figure
PT
KX-T7600 series DPT/DSS console
1
KX-T7560/KX-T7565 DPT
1
Other DPT/DSS console
1
APT
1
IP-PT
1
Extension Card *1
DHLC8
8
SLC8
8
SLC16
16
MSLC16
16
CS (1 unit)
0
PT-interface CS (1 unit)
0
ISDN Extension
0
VPS (1 port)
1
*1 Only the extension cards that can support SLTs count for the MEC figures.
7
KX-TDA200UA
4.3.3. Power Supply Unit Selection
Main unit (Hybrid IP-PBX) needs an optional power supply unit (PSU) suitable for its configuration. Calculate the amount of
"load figures" from the type and number of equipment to be connected, and determine the type of PSU that will be required.
Load Figure Calculation
Equipment Type
Load Figure
PT
KX-T7600 series DPT/DSS console
1
KX-T7560/KX-T7565 DPT
1
Other DPT/DSS console
4
APT
4
IP-PT
0
Extension Card *1
DHLC8
8
SLC8
8
SLC16
16
MSLC16
16
CS (1 unit)
4
PT-interface CS (1 unit)
4
ISDN Extension
2
VPS (1 port)
1
*1 Only the extension cards that can support SLTs count for the load figures.
PSU Capability
Each PSU supports a different amount of load figures.
PSU Type
Maximum Load Figures
PSU-M *2
128
PSU-L
512
*2 Available for the KX-TDA100 and KX-TDA200.
8
KX-TDA200UA