     KX-NCP500UA
4.6.4.
Alarm Signal Transmission Section
Part 4 contains a description of the circuit that transmits AC and DC alarm signals.
1. Alarm Circuit Power Source
Consisting primarily of Q501 and D502, the alarm circuit power source stabilizes 41V output voltage described in Part 2 to
approximately 27V. 
2. AC Alarm Signal Transmission Section
If AC input is detected by the AC voltage detection circuit described in Part 1 (5), Q801 is turned on by secondary side transis-
tor of PC80 being turned on, and a low signal is transmitted to AC alarm output. 
On the contrary, if AC input is not detected, Q801 is turned off by secondary side transistor of PC80 being turned on, and
"open" (open collector output) is transmitted to AC alarm output. 
3. DC Alarm Signal Transmission Section
If 15VPT/41V output is output normally, and output voltage detection transistor Q551/Q550 is on, Q901 is turned on and a DC
alarm output low signal is transmitted. 
If either 15VPT or 41V output is abnormal, Q901 is turned off by transistor Q551/Q550 being off, and DC alarm output "open"
(open collector output) is transmitted. 
30
KX-NCP500UA
4.6.5.
Protective Circuit Operation Section
Part 6 provides a description of the overvoltage/overheat protection circuits. 
1. Abnormal State Detection Circuit
The abnormality detection circuit consists of the transistor Q520/Q521 thyristor circuits. 
If power operation becomes abnormal and a signal is transmitted to the abnormality detection circuit, Q521 is turned on, cur-
rent flows to the diode of PC50 and is transmitted to the control circuit of the main converter, thereby shutting down main con-
verter operation. (See Part 2)
2. Overheat Protection Circuit
When temperature inside the power source rises to an abnormal temperature, the resistance of posister PTC540 rises, tran-
sistor Q540 is turned on, and the signals transmitted to the abnormality detection circuit via D542. 
3. Overvoltage Protection Circuit
If voltage of either 15V, 15VPT or 41V output becomes excessively high, the voltage is transmitted to the abnormality detec-
tion circuit via Zener diode D526. 
31
     KX-NCP500UA
5 Location of Controls and Components
5.1.
Name and Locations
32
KX-NCP500UA
6 Installation Instructions
6.1.
System Components
Category
Model No.
Description
Main Unit
KX-NCP500UA
Main Unit
Main Processing Card 
IP Convergence Main Processing Card (IPCMPR)
IPCMPR Option Cards
KX-NCP1104XJ
KX-TDE0110XJ
KX-TDE0111XJ
KX-TDA0196XJ
4-Channel VoIP DSP Card (DSP4)
16-Channel VoIP DSP Card (DSP16)
64-Channel VoIP DSP Card (DSP64)
Remote Card (RMT)
Small Free Slot
Physical CO Line Cards
KX-NCP1180X
4-Port Analogue Trunk Card (LCOT4)
KX-NCP1280XJ
2-Port BRI Card (BRI2)
KX-NCP1290CJ
PRI Card (PRI30)
Regular Free Slot
Physical Trunk Card
KX-NCP1188XJ
E-1 Trunk Card (E1)
Physical Extension Cards
KX-NCP1171XJ
8-Port Digital Extension Card (DLC8)
KX-NCP1172XJ
16-Port Digital Extension Card (DLC16)
KX-NCP1173XJ
8-Port Single Line Telephone Extension Card (SLC8)
KX-NCP1174XJ
16-Port Single Line Telephone Extension Card (SLC16)
Other Physical Card
KX-NCP1190XJ
Optional 3-Slot Base Card (OPB3)
OPB3
Other Physical Cards
KX-TDA0161XJ
4-Port Doorphone Card (DPH4)
KX-TDA0166XJ
16-Channel Echo Canceller Card (ECHO16)
KX-TDA0191XJ
4-Channel Message Card (MSG4)
KX-TDA0192XJ
2-Channel Simplified Voice Message Card (ESVM2)
KX-TDA0194XJ
4-Channel Simplified Voice Message Card (ESVM4)
Cell Stations (CSs)
DECT
KX-TDA0141CE
DECT 2-Channel Cell Station Unit Using a DHLC/DLC Card (PT-interface CS) for
DECT Portable Station 
KX-TDA0158CE
DECT 8-Channel Cell Station Unit Using a DHLC/DLC Card (PT-interface CS) for
DECT Portable Station
Proprietary Equipment
KX-T30865X
Doorphone
KX-T7765X
Page of 127
Display