DOWNLOAD Panasonic KV-SS905C Service Manual ↓ Size: 4.92 MB | Pages: 127 in PDF or view online for FREE

Model
KV-SS905C
Pages
127
Size
4.92 MB
Type
PDF
Document
Service Manual
Brand
Device
Service Manual / Other / SCANNER
File
kv-ss905c.pdf
Date

Panasonic KV-SS905C Service Manual ▷ View online

Classified Code
Error Code
Possible Cause
Check point
F55:
Exit (Front) sensor error
45 00 00 00
Exit (Front) sensor error occurs.
1. To confirm Exit (Front) sensor operates
properly, execute Document Sensor Test
and Sensor Sensitive Level 
in Test Mode.
2. Remove paper dust around the sensor.
3. Confirm each cable and connector
condition as follows.
a. Between CN10 on EXIT [FRONT]
Board and CN2012 on MOTHER Board
b. Between CN1001 and CN2001
4. 1
st
pin on CN10 : More than 4.5V (DC)?
5. Replace EXIT [FRONT] Board.
6. Replace MOTHER Board.
7. Replace MAIN Board.
F56:
Exit (Rear) sensor error
46 00 00 00
Exit (Rear) sensor error occurs.
1. To confirm Exit (Rear) sensor operates
properly, execute Document Sensor Test
in Test Mode.
2. Remove paper dust around the sensor.
3. Confirm each cable and connector
condition as follows.
a. Between Exit (Rear) sensor and CN14
on POINTER Board
b. Between CN15 on POINTER Board and
CN2011 on MOTHER Board
c. Between CN1001 and CN2001
4. 1
st
pin on CN14 : More than 4.5V (DC)?
5. Replace Exit (Rear) sensor.
6. Replace POINTER Board.
7. Replace MOTHER Board.
8. Replace MAIN Board.
F57:
Edge limit [R] Sensor
48 00 00 00
Edge limit [R] sensor error occurs.
1. To confirm edge limit [R] sensor operates
properly, execute Document Sensor Test
and Sensor Sensitive Level 
in Test Mode.
2. Remove paper dust around the sensor.
3. Confirm each cable and connector
condition as follows.
a. Between CN19 on SKEW [R] Board
and CN28 on RELAY [UPPER] Board
b. Between CN27 on RELAY [UPPER]
and CN2014 on MOTHER Board
c. Between CN1001 and CN2001.
4. 3
rd
pin on CN19 : More than 4.5V (DC)?
5. Replace SKEW [R] Board.
6. Replace RELAY [UPPER] Board.
7. Replace MOTHER Board.
8. Replace MAIN Board.
101
KV-SS905C
Classified Code
Error Code
Possible Cause
Check point
F58:
Edge limit [L] sensor
49 00 00 00
Edge limit [L] sensor error occurs.
1. To confirm edge limit [L] sensor operates
properly, execute Document Sensor Test
and Sensor Sensitive Level 
in Test Mode.
2. Remove paper dust around the sensor.
3. Confirm each cable and connector
condition as follows.
a. Between CN33 on SKEW [L] Board and
CN28 on RELAY [UPPER] Board
b. Between CN27 on RELAY [UPPER]
and CN2014 on MOTHER Board
c. Between CN1001 and CN2001
4. 5
th
pin on CN33 : More than 4.5V (DC)?
5. Replace SKEW [L] Board.
6. Replace RELAY [UPPER] Board.
7. Replace MOTHER Board.
8. Replace MAIN Board.
F60:
Front side gain error
50 00 00 00
Front side gain error occurs.
1. Check front side lamp lights properly.
2. Check front side lamp is installed to front
side Lamp module properly.
3. Execute CCD Test in Test Mode.
Amp value is changing during this test?
4. Confirm each cable and connector
condition as follows.
a. Between Front side lamp and CN2 on
LAMP INVERTER Board
b. Between CN1 on LAMP INVERTER
Board and CN2026 on MOTHER Board
c. Between CN5101 on CCD Board
[FRONT] and CN2005 on MOTHER
Board
d. Between CN5102 on CCD Board
[FRONT] and CN2002 on MOTHER
Board
e. Between CN5103 on CCD Board
[FRONT] and CN1002 on MAIN Board
5. Check input level (Test pin : TPFRO,
TPFRE, TPFGO, TPFGE, TPFBO, TPFBE)
6. Replace faulty cables.
7. Replace front side lamp.
8. Replace front lamp module.
9. Replace LAMP INVERTER Board.
10. Replace Front Side Optical Unit.
11. Replace MAIN Board.
102
KV-SS905C
Classified Code
Error Code
Possible Cause
Check point
F62:
Back side gain
52 00 00 00
Back side gain error occurs.
1. Check back side lamp lights properly.
2. Check back side lamp is installed to back
side lamp module properly.
3. Execute CCD Test in Test Mode.
Amp value is changing during this test?
4. Confirm each cable and connector
condition as follows.
a. Between back side lamp and CN3 on
LAMP INVERTER Board
b. Between CN1 on LAMP INVERTER
Board and CN2026 on MOTHER Board
c. Between CN5101 on CCD Board
[BACK] and CN2004 on MOTHER
Board
d. Between CN5102 on CCD Board
[BACK] and CN2002 on MOTHER
Board
e. Between CN5103 on CCD Board
[BACK] and CN1003 on MAIN Board
5. Check input level (Test pin : TPBRO,
TPBRE, TPBGO, TPBGE, TPBBO,
TPBBE).
6. Replace faulty cables.
7. Replace back side lamp.
8. Replace back lamp module.
9. Replace LAMP INVERTER Board.
10. Replace Back Side Optical Unit.
11. Replace MAIN Board.
F70:
Size sensor error
47 ×× 00 00
Size sensor error occurs.
1. To confirm size sensor operates properly,
execute Document Sensor Test in Test
Mode.
2. Remove paper dust around the sensor.
3. Confirm each cable and connector
condition as follows.
a. Between CN3 on SIZE Board and CN6
on HOPPER [CONNECTOR] Board
b. Between CN8 on HOPPER
[CONNECTOR] Board and CN2027 on
MOTHER Board
c. Between CN1001 and CN2001
4. Replace SIZE Board.
5. Replace HOPPER [CONNECTOR] Board.
6. Replace MOTHER Board.
7. Replace MAIN Board.
103
KV-SS905C
Classified Code
Error Code
Possible Cause
Check point
F80:
Double feed sensor error
60 ×× ×× 00
Double feed sensor error occurs.
1. To confirm double feed detector operates
properly, execute Double Feed Test in
Test Mode.
2. Remove paper dust around the sensor.
3. Confirm each cable and connector
condition as follows.
a. Between CN12 on DOUBLE FEED
DETECTOR [G] Board and CN13 on
RELAY [LOWER] Board
b. Between CN16 on RELAY [LOWER]
Board and CN2011 on MOTHER Board
c. Between CN2014 on MOTHER Board
and CN27 on RELAY [UPPER] Board
d. Between CN26 on RELAY [UPPER]
Board and CN21 on DOUBLE FEED
DETECTOR (R) Board
4. Adjust Double Feed Detector in Test Mode.
5. Replace DOUBLE FEED DETECTOR (G)
Board.
6. Replace RELAY [LOWER] Board.
7. Replace DOUBLE FEED DETECTOR (R)
Board.
8. Replace RELAY [UPPER] Board.
9. Replace MOTHER Board.
10. Replace MAIN Board.
H40:
Front side lamp lighting
error
54 ×× ×× 00
Front side lamp lighting error occurs.
1. Check front side lamp lights properly.
2. Check front side lamp is installed to front
side lamp module properly.
3. Confirm each cable and connector
condition as follows.
a. Between front side lamp and CN2 on
LAMP INVERTER Board
b. Between CN1 on LAMP INVERTER
Board and CN2026 on MOTHER Board
c. Between CN5101 on CCD Board
[FRONT] and CN2005 on MOTHER
Board
d. Between CN5102 on CCD Board
[FRONT] and CN2002 on MOTHER
Board
e. Between CN5103 on CCD Board
[FRONT] and CN1002 on MAIN Board
4. Replace faulty cables.
5. Replace front side lamp.
6. Replace front lamp module.
7. Replace LAMP INVERTER Board.
8. Replace Front Side Optical Unit.
9. Replace MAIN Board.
104
KV-SS905C
Page of 127
Display