Panasonic KV-S7065C (serv.man2) Service Manual / Supplement ▷ View online

9
Note:
*1
: This item is available only when the optional Imprinter is installed to the scanner “KV-S7065C
     Series.”
*2
: Firmware Version 1.21 or later will enable this function. (With the Version 1.10 or older,
     clicking "Feed Speed"on the main menu causes an error message.)   
Remarks
  (1) Parameter setting by user
  (2) Status indication
  (3) Parameter setting by service person
  (4) Adjustment
  (5) Diag.
  (6) Maintenance
10
4.3.
“Section 9.3 Operation”
This section describes each operation (or status indication), according to the function item list shown in Sec.9.2.
4.3.1.
“Section 9.3.1 Scanner Status”
This function indicates scanner status, updating it every few seconds.
The status messages and its contents are as follows.
Fig. 9.3.1 Scanner Status
Classified Code
Status Message
Contents
Scanner has no error.
No error
U11, U12, U14,
U16
A paper jam has occurred.
Open the scanner’s door, remove the
documents, and close the cover.
Place the documents back in the document
feed tray.
U11: Paper feed Jam
U12: Conveyor jam1 (around Conveyor)
U13: Conveyor jam2 (around Conveyor) 
U16: Exit jam (around Exit Roller)
Note: Refer to Section 10.2 (Troubleshooting)
in the Service Manual 
(Order No.: KM70401905C0) when performing
troubleshooting for the above error codes.  
U18
Paper remains in the scanner.
Open the scanner’s door, remove the
documents, and close the cover.
Place the documents back in the document
feed tray.
Document remains in the scanner, or dust is
attached around a sensor.
U20
A skew error has occurred.
Open the scanner’s door, remove the
documents, and close the cover.
Place the documents back in the document
feed tray.
Skew error
U23
A paper double feed has occurred.
Open the scanner’s door, remove the
documents, and close the cover. 
Place the documents back in the document
feed tray.
Double feed error
U30
Scanner Door is open! Please close the door. 
Door is open.
Fxx
System error occurred!
Please consult with a service representative.
Service level error occurred.
*** Warning***
The rollers need to be cleaned.
Please clean the rollers. Please select Clear Counter
button after cleaning rollers.
Warning for cleaning rollers.
***Warning***
The replaceable rollers (consumable) are
close to reaching their usable life.
To insure reliable operation, please
replace these rollers with Roller Exchange
Kit for your specific scanner.
After replacing the rollers, select the
“Clear Counter” button.
Warning for replacing rollers.
***Warning***
Insufficient front light error occurred.
The lamp and/or scanning sensor need to be replaced.
1. The lamp have reached its life expectancy.
2. Lamp drive circuit for the front does not work 
   properly.
***Warning***
Insufficient back light error occurred.
The lamp and/or scanning sensor need to be replaced.
1. The lamp have reached its life expectancy.
2. Lamp drive circuit for the back does not work
   properly.
***Warning***
The front reference plate may need to be cleaned.
Please clean the front reference plate.
The surface of the plate is dirty.
***Warning***
The back reference plate may need to be cleaned.
Please clean the back reference plate.
The surface of the plate is dirty.
Scanner is not connected!
Scanner is not connected to PC properly.
11
4.3.2.
“Section 9.3.5 Scanner Condition”
Item
Operation
Default
Remarks
Sleep Mode
1. Click “Sleep Mode” on the main menu (Service Utility).
2. Set “Waiting Time” (minutes) to change
    sleep mode. 
3. Click “OK” to renew the setting.
15 minutes
When returning back 
to the Ready Mode
from the Sleep Mode, 
execute “Sleep Mode” 
for Test (9.3.6) on the 
main menu, and then 
click “STOP” on the 
“Sleep Mode” dialog 
box.
Clear Imprinter
1. Click “Clean Imprinter” on the main menu to clean an ink jet
    head to print.
This item is available
only when the optional
Imprinter is installed to
the scanner.
Paper Mode /
Buzzer Setting
1. Click “Paper Mode / Buzzer Setting” on the main menu.
2. Set “Paper Mode (A4 or Letter)” and/or “Buzzer Setting
    (ON or OFF)” 
on “Paper Mode / Buzzer Setting” dialog
    box.
3. Click “OK” to renew the setting.
Compatible Mode 1. Click “Compatible Mode” on the main menu.
2. Set a model number to operate the scanner as the emulation
    mode on “Compatible Mode” dialog box.
3. Click “OK” to renew the setting.
User Shading
1. Click “User Shading” on the main menu.
2. Push “Start Shading” or “Restore Default” on “User
    Shading”
 dialog box.
     Note:
a. When selecting “Restore Default”, the factory-setting
    data will be overwritten in stead of the current
    shading data.
b. The following procedures “3” or more are available
    only for selecting “Start Shading”.
3. Clean the conveyor, rollers, and ADF glasses according to
    the message on the display.
    
And click “OK”.
4. Reverse Reference Plates to white according to the message
   on the display.
    
And click “OK”.
5. Set the accessory Shading Paper or Shading Paper
    (Part No.: See 14.7.) on the Hopper Tray in the landscape
    orientation.
    
And click “OK”.
6. Scan the Shading Paper.
7. Reverse the Reference Plates to black according to the
   message on the display.
   And click “OK”.
8. Click “OK” to get back to the main menu.
1. Before executing the
    shading function, be sure to
    clean ADF Glasses, rollers,
    and conveyors related to
    convey documents.
2. Do not stop the shading
    execution on its way and
    do not open any doors.
Warning Setting
1. Click “Warning Setting” on the main menu. 
2. Change the parameter on “Warning Setting” dialog box.
3. Click “OK” to renew the setting.
Clean: 
20000
Replace:
300000
Set Default
1. Click “Set Default” on the main menu. 
2. Click “Set Default” on the “Set Default”
    dialog box to set “Sleep Mode”, “Warning
    Setting”, and “Feed Speed” to the default.
 
3. Click “Close” to get back to the main menu.
12
4.3.3.
“Section 9.3.6 Test”
Note:
*1
: When scanning image has some lines, this operation (Focus test) will find their
     locations on the image.
     When this operation is executed, the figure of the scanning level will indicate,
     beginning at the left of the scanning device.
    This focus test shows partial depression of the level if there are some damages
    (scratch or others) to the glass surface or a dust on the surface.
     If there are some damages to the glass, replace it.
    When this phenomenon appears (with no damage to the glass surface), clean the
    surface with Roller Cleaning Paper we provide. And then if the lines still remain,
    execute "Shading". 
Item
Operation
Default
Remarks
*1
 CIS Focus 1. Pull the Front Door Release to open the
    Front Door.
2. Reverse the Reference Plates to white.
3. Close the Front Door slowly until it clicks
    into place.
4. Click “CIS Focus” on the main menu.
5. Click “START” on the “CIS Focus” dialog
    box.
6. Check the waveform indicated on the display.
7. When finishing confirming the output image
    level, click “STOP” on the “CIS Focus”
    dialog box.
8. Click “Close” to get back to the main menu.
9. Pull the Front Door Release to open the
    Front Door, and then reverse the Reference
    Plates to black.
10. Close the Front Door slowly until it clicks
      into place.
This operation
indicates a focus-level
waveform to check
whether there is any
partial depression of
the level.
Page of 27