DOWNLOAD Panasonic KV-S1026C / KV-S1015C (serv.man2) Service Manual ↓ Size: 5.82 MB | Pages: 127 in PDF or view online for FREE

Model
KV-S1026C KV-S1015C (serv.man2)
Pages
127
Size
5.82 MB
Type
PDF
Document
Service Manual
Brand
Device
Service Manual / Other / DOCUMENT SCANNER
File
kv-s1026c-kv-s1015c-sm2.pdf
Date

Panasonic KV-S1026C / KV-S1015C (serv.man2) Service Manual ▷ View online

73
F61: Front-side 
black level error
51
00
00
00 1. Problem with Pixel data from
    CIS (F) or from image
    processing circuit
1. Check the connection and soldering condition of
    the following parts.
      (1) between CIS and CN1 (CONTROL Board)
2. Check the soldering condition of the following parts
    and of their surrounding circuits on the CONTROL
    Board.
       (1) IC1
       (2) IC2 (AFE)
       (3) IC6 (D/A Conv.)
3. Monitor the following CIS Timing signals on the
    CN1.
       (1) CLK (CN1-5th pin) : See Fig. 10.2.1.
       (2) SI (CN1-7th pin)     : See Fig. 10.2.2.
4. Replace faulty parts or boards.
F62: Back-side 
gain adjustment 
error
52
00
00
00 1. The surface of Scanning
    Glass (B) is dirty.
Clean the surface with a soft and dry cloth.
2. Problem with Pixel data from 
    CIS (B) or from image
    processing circuit 
1. Check the connection and soldering
    condition of the following parts.
      (1) between CIS (B)
            and CN2 (CONTROL Board)
2. Check the soldering condition of the following
    parts and of their surrounding circuits on the 
    CONTROL Board.
       
(1) IC1
       
(2) IC2 (AFE)
       
(3) IC6 (D/A Conv.)
3. Monitor the following CIS Timing signals on
    the CN2.
       
(1) CLK (CN2-5th pin) : See Fig. 10.1.1.
       
 (2) SI (CN2-7th pin)      : See Fig. 10.1.2.
4. Replace faulty parts or boards.
F63: Back-side 
black level error 
53
00
00
00 Problem with Pixel data from 
CIS (B) or from image 
processing circuit
1. Check the connection and soldering
    condition of the following parts.
       (1) between CIS (B)
             and CN2 (CONTROL Board)
2. Check the soldering condition of the following
    parts and of their surrounding circuits on the
    Control Board.
 
       
(1) IC1
        
(2) IC2 (AFE)
         
(3) IC6 (D/A Conv.)
3. Monitor the following CIS Timing signals on
    the CN2.
       
(1) CLK (CN2-5th pin) : See Fig. 10.2.1.
       
 (2) SI (CN2-7th pin)     : See Fig. 10.2.2.
4. Replace faulty parts or boards.
Error Code
Possible Cause
Check Point
Classified Code ST1 ST2 ST3 ST4
74
F71: Model ID
Error
9F
00
00
00 A wrong type board for the
model No. is installed.
1. For KV-S1026C Series
       (1) Check whether red dots are stamped on 
              the CONTROL Board’s silk “1026”.
           
(The red dots indicate the supported Model No.)
                => If no, replace the board.
       (2) Check whether red dots are stamped on 
              the PANEL Board’s silk “1026”.
           
(The red dots indicate the supported Model No.)
                => If no, replace the board.
2. For KV-S1015C Series
      (1) Check whether red dots are stamped on 
              the CONTROL Board’s silk “1015”.
          
(The red dots indicate the supported Model No.)
                => If no, replace the board.
      (2) Check whether red dots are stamped on 
              the PANEL Board’s silk “1015”.
          
(The red dots indicate the supported Model No.)
 
                => If no, replace the board. 
F80: Double
Feed Detector
error
60
00
00
00 1. Double Feed Detector
     (Generate) does not work
     properly.
Same as the 5th item of U23
2. Double Feed Detector
     (Receive) does not work
     properly.
Same as the 6th item of U23
Error Code
Possible Cause
Check Point
Classified Code ST1 ST2 ST3 ST4
75
Fig.10.2.1
Fig.10.2.2
Fig.10.2.3
76
Fig.10.2.4
Fig.10.2.5
Page of 127
Display