9. METHOD OF MASSAGE MECHANISM BLOCK INSTALLATION
MODE SET-UP (MANUAL SET-UP)
MODE SET-UP (MANUAL SET-UP)
It is necessary to adjust the Massage mechanism block to Manual mode when installing or removing the Massage mechanism
block or adjusting the Up/down position as follows:
1. Insert the Power plug into the power source and turn on the switch of the Power source switch block.
2. While pushing the buttons of Ⅱ and Ⅳ, continue to push the On/off button for more than approximately three seconds.
Then, the buttons of Ⅱ, Ⅳ, and USER B light.
3. In ten seconds after the buttons of Ⅱ, Ⅳ, and USER B light, push the buttons as follows:①SELF PROGRAM⇒②
REGIONAL ROLL⇒③START
4. Move the Massage mechanism block pushing the buttons of POSITION and BACK INTENSITY.
5. Push the button of Stop after checking.
EP30002
ORDER NO.HPD0704X10C8
-
14 -
10. DISASSEMBLY
10.1. Removing the Rear cover
1. Remove two screws and two push-turn rivets, and pull off the
Rear cover top.
2. Remove two brushclips from the Rear cover bottom, and pull off
the Rear cover bottom.
10.2. Removing the Massage mechanism block
Move the Massage mechanism block to the bottom pushing the
high/low adjustment button.
1. Unscrew four screws on the PCB cover, and remove the PCB
cover.
EP30002
ORDER NO.HPD0704X10C8
-
15 -
2. Unscrew a screw on the Ground wire and disconnect two
Connectors.
3. Remove the Connecting cord for power source from the Massage
block cover clip.
4. Unscrew four screws each on both sides and remove the Rail
piece sets.
Caution
The Massage mechanism block may fall down, therefore hold it
by your hand.
Be careful of the directions of the Rail piece sets when installing.
EP30002
ORDER NO.HPD0704X10C8
-
16 -
Caution when handling the Massage mechanism block
Be sure to handle the Massage mechanism block carefully so that the
PCB of the Pressure sensor is not pushed to the desk or given extra
pressure when putting the Massage mechanism block, which could lead
to the cracks of the PCB. This may eventually cause the malfunction
such as ‘The body pressure levels on the Controller does not increase.’
‘It does not scan.’or ‘The operation is not stable.’ etc.
10.3. Removing the Controller stand and the Armrest
10.3.1. Removing the Controller
1. Pull off the parts A with a slotted screwdriver.
2. Take off the Controller from the Controller stand, and unscrew
three hexagonal screws and remove the Controller stand.
10.3.2. Removing the Armrest
1. Unscrew two screws from inside and outside the Armrest.