Panasonic EP-MA70CX890 / EP-MA70KX890 Service Manual ▷ View online
EP-MA70
ORDER NO. HPD1102E25CE
-
61 -
9.4. Display of each operation time [C3]
1. Proceed the procedures of 9.1. Preparation of Secret Mode.
2. Push the button of BACK INTENSITY till C3 appears, and push the OK button twice.
3. Then, push the BACK INTENSITY and choose from 01 to 08, and from 11 to 16.
4. Push the OK again, then 1,000’s place, 100’s plate, ten’s place, and single’s place are shown every time
you push the OK button.
5.If you push the OK, again, it buzzes once, then the operation resumes to 3.
EP-MA70
ORDER NO. HPD1102E25CE
-
62 -
9.5. Display of malfunction analysis-1 [C4]
. Category of abnormal stop is shown.
1. Proceed the procedures 1-4 of 9.1. Preparation of Secret Mode.
2. Push the button of BACK INTENSITY till C4 appears, and push the OK button. Any of the following is
shown.
9.6. Display of malfunction analysis-2 [C6]
. It is shown at which operation the Massage block stops abnormally
.
1. Proceed the procedures of 9.1. Preparation of Secret Mode.
2. Push the button of BACK INTENSITY till C6 appears, and push the OK button. Any of the following is
shown.
EP-MA70
ORDER NO. HPD1102E25CE
-
63 -
9.5. Display of malfunction analysis-1 [C4]
. Category of abnormal stop is shown.
1. Proceed the procedures 1-4 of 9.1. Preparation of Secret Mode.
3. Push the button of BACK INTENSITY till C4 appears, and push the OK button. Any of the following is
shown.
9.6. Display of malfunction analysis-2 [C6]
. It is shown at which operation the Massage block stops abnormally
.
1. Proceed the procedures of 9.1. Preparation of Secret Mode.
2. Push the button of BACK INTENSITY till C6 appears, and push the OK button. Any of the following is
shown.
EP-MA70
ORDER NO. HPD1102E25CE
-
64 -
9.7. Display of malfunction analysis-3 [C7]
It is shown which parts were stalled in the abnormal stop.
1. Proceed the procedures of 9.1. Preparation of Secret Mode.
2. Push the button of BACK INTENSITY till C7appears, and push the OK button. Any of the following is
shown.
9.8. Display of malfunction analysis-4 [C8]
It is shown in which sensing is when the abnormal stop occurred.
1. Proceed the procedures 1-4 of 9.1. Preparation of Secret Mode.
2. Push the button of BACK INTENSITY till C8 appears, and push the OK button. Any of the following is
shown.
Click on the first or last page to see other EP-MA70CX890 / EP-MA70KX890 service manuals if exist.