DOWNLOAD Panasonic EP-MA70CX890 / EP-MA70KX890 Service Manual ↓ Size: 7.82 MB | Pages: 82 in PDF or view online for FREE

Model
EP-MA70CX890 EP-MA70KX890
Pages
82
Size
7.82 MB
Type
PDF
Document
Service Manual
Brand
Device
Service Manual / Other / MASSAGE LOUNGER
File
ep-ma70cx890-ep-ma70kx890.pdf
Date

Panasonic EP-MA70CX890 / EP-MA70KX890 Service Manual ▷ View online

EP-MA70 
ORDER NO. HPD1102E25CE
 
-
 57 - 
 
EP-MA70 
ORDER NO. HPD1102E25CE
 
-
 58 - 
8.3. Wiring diagram of Main PCB and Sub PCB 
The following values are in the standby conditions with the Off/On switch on the Controller pushed. 
Values with  *  are when each operations are executed.  (Output voltages are approximate.)
 
Remove Connectors to check the resistance of the parts. 
 
EP-MA70 
ORDER NO. HPD1102E25CE
 
-
 59 - 
9. SECRET MODE 
9.1. Preparation of Secret Mode 
Before proceeding to each Secret Modes, execute the following Preparation of the Secret Mode.    Insert the 
Power plug to the power source and turn on the Switch on the Power source switch box. 
1. Turn on the Switch on the Power source switch box. 
2. While pushing the buttons of REFRESH and HIP, keep pushing the Off/On button for more than three seconds. 
(REFRESH, HIP, and USER3 lights and it buzzes three times.) 
3. Push NECK, then SHOULDER of MANUAL, and at final push the OK button. 
(CO is displayed on the screen.) 
*  You can choose each operation modes in the Secret Mode list by pushing the 
BACK INTENSITY button.    After choosing, push the OK button. 
You can resume to the Secret Mode list by pushing the OK button for more than three seconds. 
 
 
EP-MA70 
ORDER NO. HPD1102E25CE
 
-
 60 - 
9.2. Display of total usage time [C0] 
1. Proceed the procedures 1-4 of 9.1. Preparation of Secret Mode. 
2. Push the button of BACK INTENSITY till C0 appears, and push the OK button. 
3. Push the OK again, then 1,000’s place, 100’s plate, ten’s place, and single’s place 
    are shown every time you push the OK button.
 
 
9.3. Input of total usage time [C2 01] 
1. Proceed the procedures 1-4 of 9.1. Preparation of Secret Mode. 
2. Push the button of BACK INTENSITY till C2 appears, and push the OK button twice. 
3. Push the button of BACK INTENSITY till 01 appears, and push the OK button. 
4. Push the button of BACK INTENSITY and push the OK button in which you want to input Nos. 
    Input the operation time from place of 1,000, place of 100, place of 10, and to place of 1. 
 
Page of 82
Display

Click on the first or last page to see other EP-MA70CX890 / EP-MA70KX890 service manuals if exist.