Panasonic EP-MA51 / EP-MA51CX800 Service Manual ▷ View online
EP-MA51
ORDER NO. HPD0908A16C3
-
61 -
11.8. Display of the malfunction display –④`C8’
Display shows at which sensor position it is when the operation stopped for malfunction.
1.First, execute the procedures of 11.1. Preparing the Secret mode ①-④.
2.Dial the Intensity dial to `C8’ and push the OK. Display shows the Nos. of the malfunction.
EP-MA51
ORDER NO. HPD0908A16C3
-
62 -
11.9. Display of the malfunction display –⑤`C9’
Display shows the conditions or records when the operation stopped for malfunction.
1.First, execute the procedures of 11.1. Preparing the Secret mode ①-④.
2.Dial the Intensity dial to `C9’ and push the OK.
3.After pushing the OK again, dial the Intensity dial to the No, which you want to check.
4.If you push the OK, the contents are shown in the screen.
EP-MA51
ORDER NO. HPD0908A16C3
-
63 -
11.10. Check of the Massage mechanism block operation`CA’
Check if the Massage mechanism block is assembled properly or there is nothing wrong with Sensors or Motors.
1.First, execute the procedures of 11.1. Preparing the Secret mode ①-④.
2.Dial the Intensity dial to `CA’ and push the OK. Massage mechanism block starts operating.
EP-MA51
ORDER NO. HPD0908A16C3
-
64 -
11.11. Adjustment of the pressure sensor `CC’
Caution
Every time after the Main PCB or the Intensity block is replaced, the adjustment of the Pressure sensor is necessary.
Execute this adjustment without the load on the Massage balls.
If the Massage mechanism block is at the highest or lowest, the proper adjustment cannot be executed because the
Massage wheel cover is tense.
1.First, execute the procedures of 11.1. Preparing the Secret mode ①-④.
2.Dial the Intensity dial to `CC’ and push the OK.
3.Push the Stop button. Then, the adjustment is done.
Click on the first or last page to see other EP-MA51 / EP-MA51CX800 service manuals if exist.