DOWNLOAD Panasonic HDC-TM10PP / HDC-TM10PU / HDC-TM10EB / HDC-TM10EC / HDC-TM10EE / HDC-TM10EF / HDC-TM10EP / HDC-TM10GC / HDC-TM10GK / HDC-TM10GN / HDC-SD10PP / HDC-SD10PU / HDC-SD10EB / HDC-SD10EC / HDC-SD10EE / HDC-SD10EF / HDC-SD10EG / HDC-SD10EP / HDC-SD10GC / HDC-SD10 Service Manual ↓ Size: 4.18 MB | Pages: 76 in PDF or view online for FREE

Model
HDC-TM10PP HDC-TM10PU HDC-TM10EB HDC-TM10EC HDC-TM10EE HDC-TM10EF HDC-TM10EP HDC-TM10GC HDC-TM10GK HDC-TM10GN HDC-SD10PP HDC-SD10PU HDC-SD10EB HDC-SD10EC HDC-SD10EE HDC-SD10EF HDC-SD10EG HDC-SD10EP HDC-SD10GC HDC-SD10
Pages
76
Size
4.18 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / HIGH DEFINITION VIDEO CAMERA
File
hdc-tm10pp-hdc-tm10pu-hdc-tm10eb-hdc-tm10ec-hdc-tm.pdf
Date

Panasonic HDC-TM10PP / HDC-TM10PU / HDC-TM10EB / HDC-TM10EC / HDC-TM10EE / HDC-TM10EF / HDC-TM10EP / HDC-TM10GC / HDC-TM10GK / HDC-TM10GN / HDC-SD10PP / HDC-SD10PU / HDC-SD10EB / HDC-SD10EC / HDC-SD10EE / HDC-SD10EF / HDC-SD10EG / HDC-SD10EP / HDC-SD10GC / HDC-SD10 Service Manual ▷ View online

17
6 Service Mode
1. Indication method of the service menu
Set the mode switch “Recording” mode.
2. While keep pressing the “Intelligent auto” button, “Manual” button and “Menu” button for more than 3 seconds until the top
screen of the Service Mode Menu being displayed.
Service mode menu
NOTE:
Do not using service mode except above table of Service Menu.
3. End method of the top screen of the service menu
Push the “Menu” button to end the service mode, and then POWER OFF.
Screen display
Contents
Function
1
Factory settings
Function to throw a product up in a factory shipment state
(When recorded data in Built-in memory, “error display” is done)
3
Built-in memory self check execution
(HDC-TM10 only)
Function to check self as for the state of Built-in memory
4
Lock search history indication
Display the camera system error cord for three histories saved
in EEPROM
5
Power ON self check result display
Power  ON  self check (function to diagnose correct function of
the device and interface between devices) result display
18
6.1.
Built-in Memory Self Check (HDC-TM10 only)
1. Set the mode switch “Recording” mode.
2. While keep pressing the “Intelligent auto” button, “Manual” button and “Menu” button for more than 3 seconds until the top
screen of the Service Mode Menu being displayed.
3. Touch the [ 3 ] of LCD, select Built-in memory self check.
Operation specifications
Indication contents
• Built-in memory self check result display
Display the Built-in memory self check result information.
Displays other than “OK” are abnormalities of Built-in memory.
Push the “Menu” button to end the service mode, and then POWER OFF.
19
6.2.
Lock Search History Indication
1. Set the mode switch “Recording” mode.
2. While keep pressing the “Intelligent auto” button, “Manual” button and “Menu” button for more than 3 seconds until the top
screen of the Service Mode Menu being displayed.
3. Touch the [ 4 ] of LCD, select Lock search history indication.
Operation specifications
Indication contents
• Lock search history indication
Display the camera system error cord for three histories saved in EEPROM.
• The error cord contents which are displayed
Push the “Menu” button to end the service mode, and then POWER OFF.
Error code
Function
51
Focus control is abnormal
52
Zoom control is abnormal
53
OIS lens control is abnormal
71
Lens cover open/close is abnormal
72
Cooling fan is abnormal
73
High temperature is abnormal
33
Communication between camera to ARM is abnormal
20
6.3.
Power ON Self Check Result Display
1. Set the mode switch “Recording” mode.
2. While keep pressing the “Intelligent auto” button, “Manual” button and “Menu” button for more than 3 seconds until the top
screen of the Service Mode Menu being displayed.
3. Touch the [ 5 ] of LCD, select Power ON self check result display.
Operation specifications
Indication contents
• Power ON self check result display
Function to diagnose correct function of the device and interface between devices result display.
Display the following commnucation test result.
- CAM-PWR : Commnucation test between IC2006 to IC301
- CAM-UNI : Commnucation test between IC3400 to IC301
Display other than “OK” are abnomalities of each lines.
Push the “Menu” button to end the service mode, and then POWER OFF.
Page of 76
Display

Click on the first or last page to see other HDC-TM10PP / HDC-TM10PU / HDC-TM10EB / HDC-TM10EC / HDC-TM10EE / HDC-TM10EF / HDC-TM10EP / HDC-TM10GC / HDC-TM10GK / HDC-TM10GN / HDC-SD10PP / HDC-SD10PU / HDC-SD10EB / HDC-SD10EC / HDC-SD10EE / HDC-SD10EF / HDC-SD10EG / HDC-SD10EP / HDC-SD10GC / HDC-SD10 service manuals if exist.