Panasonic NT-T13P (serv.man3) Service Manual ▷ View online
2.7 How to remove the timer
Unsolder the power cord and timer to remove the power cord from the timer terminal. (
Fig.14
)
1.
Remove the timer knob and then loosen the 2 screws. (
Fig.15
)
2.
Fig.14
No. Parts Name
1
Front plate
2
Timer
A
Unsolder
Fig.15
No.
Parts Name
1
Front plate
2
Timer knob
file:///C|/Ìîè äîêóìåíòû/NT_T13/s0207000000.html (1 of 2) [10.01.2002 10:37:42]
3
Screw(3x5)
file:///C|/Ìîè äîêóìåíòû/NT_T13/s0207000000.html (2 of 2) [10.01.2002 10:37:42]
3.1 Cautions
Securely tighten the wiring screws securely and connect the positive lock connectors or other
connectors./Double-check that they are all tight in position.
connectors./Double-check that they are all tight in position.
1.
Do not disconnect or reconnect any connector by holding the lead wire./This could cut the lead
wire.
wire.
2.
file:///C|/Ìîè äîêóìåíòû/NT_T13/s0301000000.html [10.01.2002 10:37:44]
3.2 Points to check after assembly
After assembly, carry out the following tests.
Insulation resistance/Shall be 2 M© or more when measured with a 500V DC insulation-resistance
tester./Measuring point: Between the two blades of the plug and bottom plate
tester./Measuring point: Between the two blades of the plug and bottom plate
1.
Dielectric strength:/Shall withstand 1000V AC for one minute:/Measuring point: same point as the
insulation test
insulation test
2.
Grounding resistance/Shall not exceed 0.08©./Measuring point: Between the grounding terminal
and bottom plate
and bottom plate
3.
Quick performance test/Perform the "Quick performance test" described in section 3.1 to make
sure that the product functions well.
sure that the product functions well.
4.
file:///C|/Ìîè äîêóìåíòû/NT_T13/s0302000000.html [10.01.2002 10:37:45]