DOWNLOAD Panasonic NN-GD391SZPE / NN-GD371MZPE Service Manual ↓ Size: 4.03 MB | Pages: 36 in PDF or view online for FREE

Model
NN-GD391SZPE NN-GD371MZPE
Pages
36
Size
4.03 MB
Type
PDF
Document
Service Manual
Brand
Device
Home Appliance / MICROWAVE OVEN
File
nn-gd391szpe-nn-gd371mzpe.pdf
Date

Panasonic NN-GD391SZPE / NN-GD371MZPE Service Manual ▷ View online

Unlike many other appliances, the microwave oven is a high
voltage, high current device. It is free from danger in ordinary
use, though extreme care should be taken during repair.
CAUTION
Servicemen should remove their watches and rings
whenever working close to or replacing the magnetron.
5.1. Check the grounding
Do not operate on a two wire extension cord. The microwave
oven is designed to be grounded when used. It is imperative,
therefore, to ensure the appliance is properly grounded before
beginning repair work.
5.2. Inverter warnings
WARNING HIGH VOLTAGE AND HIGH TEMPERATURE
(HOT/LINE) OF THE INVERTER POWER SUPPLY (U)
The high voltage inverter power supply generates very high
voltage and current for the magnetron tube. Though it is
free from danger in ordinary use, extreme care should be
taken during repair.
The aluminum heat sink is also energized with high voltage
(HOT), do not touch when the AC input terminals are
energized. The power device Collector is directly connected
to the aluminum heat sink.
The aluminum heat sink may be HOT due to heat energy,
therefore, extreme care should be taken during servicing.
WARNING FOR INVERTER POWER SUPPLY (U)
GROUNDING
Check the high voltage inverter power supply circuit
grounding. The high voltage inverter power supply circuit
board must have a proper chassis ground. The inverter
grounding bracket must be connected to the chassis. If the
inverter board is not grounded it will expose the user to very
high voltages and cause extreme DANGER! Be sure that
the inverter circuit is properly grounded via the inverter
earth bracket.
WARNING
DISCHARGE
THE
HIGH
VOLATGE
CAPACITORS
For about 30 seconds after the oven is turned off, an
electric charge remains in the high voltage capacitors of the
inverter power supply circuit board.
When replacing or checking parts, remove the power plug
from the outlet and short the inverter output terminal of the
magnetron filament terminals to the chassis ground with an
insulated handle screwdriver to discharge. Please be sure
to contact the chassis ground side first and then short to the
output terminal.
WARNING
There is high voltage present with high current capabilities
in the circuits of the primary and secondary windings, choke
coil and heat sink of the inverter. It is extremely dangerous
to work on or near these circuits with the oven energized.
DO NOT measure the voltage in the high voltage circuit
including the filament voltage of the magnetron.
WARNING
Never touch any circuit wiring with your hand or with an
insulated tool during operation.
5 CAUTIONS TO BE OBSERVED WHEN
TROUBLESHOOTING
9
NN-GD391S / NN-GD371M
5.3. Part replacement.
When troubleshooting any part or component is to be replaced,
always ensure that the power cord is unplugged from the wall
outlet.
5.4. When the 10A fuse is blown
due to the malfunction of the
short switch:
WARNING
When the 10A 250V fuse is blown due to the malfunction of
the interlock monitor switch, replace all of the components
(primary latch switch, secondary latch switch, short switch
and power relay RY1).
 1. This is mandatory. Refer to “measurements and
adjustments” for the location of these switches.
 2. When replacing the fuse, confirm that it has the
appropriate rating for these models.
 3. When replacing faulty switches, be sure the mounting
tabs are not bent, broken or deficient in their ability to
hold the switches.
5.5. Avoid inserting nails, wire etc.
through any holes in the unit
during operation.
Never insert a wire, nail or any other metal object through the
lamp holes on the cavity or any holes or gaps, because such
objects may work as an antenna and cause microwave
leakage.
5.6. Verification after repair
 1. After repair or replacement of parts, make sure that the
screws of the oven, etc. are neither loose nor missing.
Microwave energy might leak if screws are not properly
tightened.
 2. Make sure that all electrical connections are tight before
inserting the plug into the wall outlet.
 3. Check for microwave energy leakage.
CAUTION OF MICROWAVE RADIATION LEAKAGE
USE CAUTION NOT TO BECOME EXPOSED TO
RADIATION FROM THE MICROWAVE MAGNETRON OR
OTHER PARTS CONDUCTING MICROWAVE ENERGY
IMPORTANT NOTICE
The following components have potentials above 2000V
while the appliance is operated.
 • Magnetron
 • High voltage transformer (Located on inverter (U))
 • High voltage diodes (Located on inverter (U))
 • High voltage capacitors (Located on inverter (U))
Pay special attention to these areas.
When the appliance is operated with the door hinges or
magnetron installed incorrectly, the microwave leakage can
exceed more than 5mW/cm
2
. After repair or exchange, it is
very important to check if the magnetron and the door
hinges are correctly installed.
5.7. Sharp edges
CAUTION
Please use caution when disassembling or reassembling
internal parts. Some exposed edges may be sharp to the
touch and can cause injury if not handled with care.
10
NN-GD391S / NN-GD371M
6.1. Magnetron
 1. Discharge the high voltage capacitor.
 2. Remove 1 screw holding front plate bracket on cavity top
plate.
 3. Remove 2 screws holding air guide A on cavity top plate
and on magnetron.
 4. Remove 1 screw holding air guide A on the wave guide,
then remove the air guide A.
 5. Remove 1 screw holding thermistor on the magnetron.
 6. Remove 2 screws holding the magnetron.
NOTE:
After replacement of the magnetron,tighten mounting
screws properly, making sure there is no gap between
the
waveguide
and
the
magnetron
to
prevent
microwave leakage.
CAUTION
When replacing the magnetron, be sure the antenna gasket is in
place.
6.2. Digital programmer circuit
(D.P.C)
CAUTION:
Be sure to ground any static electric charge built up in
your body before handling the D.P.C..
 1. Disconnect all connectors from D.P.C. board.
6 DISASSEMBLY AND PARTS REPLACEMENT
PROCEDURE
11
NN-GD391S / NN-GD371M
 2. Disconnect 1 grounding connector from cavity front plate.
 3. Disconnect connector CN701 from H.V. inverter.
6.3. Low voltage transformer
and/or power relays (RY1)
CAUTION:
Be sure to ground any static electric charge built up in
your body before handling the DPC.
 1. Using solder wick or a desoldering tool and 30W soldering
iron carefully remove all solder from the terminal pins of the
low voltage transformer and/or power relays.
NOTE:
Do not use a soldering iron or desoldering tool of
more than 30 watts on D.P.C. contacts.
 2. With all the terminal pins cleaned and separated from
D.P.C. contacts, remove the defective transformer/power
relays, Replace components making sure all terminal pins
are inserted completely resolder all terminal contacts
carefully.
6.4. DC fan motor
 1. Disconnect DC fan motor connect CN15 from DPC board
DU.
 2. Remove 2 screws holding orifice assy and detach the orifice
assy from oven assy.
 3. Remove 2 screws holding DC fan motor(U) on orifice assy
and detach the fan motor from orifice assy.
12
NN-GD391S / NN-GD371M
Page of 36
Display