Unlike many other appliances, the microwave oven is a high
voltage, high current device. It is free from danger in ordinary
use, though extreme care should be taken during repair.
CAUTION
Servicemen should remove their watches and rings
whenever working close to or replacing the magnetron.
5.1. Check the grounding
Do not operate on a two wire extension cord. The microwave
oven is designed to be grounded when used. It is imperative,
therefore, to ensure the appliance is properly grounded before
beginning repair work.
5.2. Inverter warnings
WARNING HIGH VOLTAGE AND HIGH TEMPERATURE
(HOT/LIVE) OF THE INVERTER POWER SUPPLY (U)
The High Voltage Inverter Power Supply generates very
high voltage and current for the magnetron tube. Though it
is free from danger in ordinary use, extreme care should be
taken during repair.
The aluminum heat sink is also energized with high voltage
(HOT), do not touch when the AC input terminals are
energized. The power device Collector is directly connected
to the aluminum heat sink.
The aluminum heat sink may be HOT due to heat energy,
therefore, extreme care should be taken during servicing.
H.V. Inverter warning
WARNING FOR
INVERTER
POWER
SUPPLY
(U)
GROUNDING
Check the High Voltage Inverter Power Supply circuit
grounding. The high voltage inverter power supply circuit
board must have a proper chassis ground. The inverter
reinforcement and grounding bracket must be connected to
the chassis. If the inverter board is not grounded it will
expose the user to very high voltages and cause extreme
DANGER! Be sure that the inverter circuit is properly
grounded via the inverter reinforcement and grounding
bracket A.
Grounding of the inverter circuit board
WARNING
DISCHARGE
THE
HIGH
VOLATGE
CAPACITORS
For about 30 seconds after the oven is turned off, an
electric charge remains in the high voltage capacitors of the
Inverter Power Supply circuit board.
When replacing or checking parts, remove the power plug
from the outlet and short the inverter output terminal of the
magnetron filament terminals to the chassis ground with an
insulated handle screwdriver to discharge. Please be sure
to contact the chassis ground side first and then short to the
output terminal.
Discharging the high voltage capacitors
WARNING
There is high voltage present with high current capabilities
in the circuits of the primary and secondary windings, choke
coil and heat sink of the inverter. It is extremely dangerous
to work on or near these circuits with the oven energized.
DO NOT measure the voltage in the high voltage circuit
including the filament voltage of the magnetron.
WARNING
Never touch any circuit wiring with your hand or with an
insulated tool during operation.
5 CAUTIONS TO BE OBSERVED WHEN
TROUBLESHOOTING
9
NN-DS596M
5.3. Confirm before repair
CAUTION
To prevent the water from invading the electric parts that can cause a
short circuit or electric shock:
1. Before repair or replacement of parts, ensure to remove the water
tank from microwave oven.
2. Select the "Drain Water" function to drain the water remaining in
the water pipes and tubes into oven drip tray forcibly. (Operating
method: Add 100g of water to the water tank
→ tap “System
cleaning”
once
→ touch "Start" pad → wait the program
finishing
→ empty the drip tray.) Then wipe up the oven cavity.
3. In case the Microwave Oven has no power, the technician should
have a dry cloth available in advance before disassembly. When
pulling out the water tube, elevate the front of the Microwave Oven
at least 1.5” to minimize the amount of water that leaks out. Wipe
up excess water throughly with the dry cloth.
WARNING
Before beginning repair work, make sure that there is no
water in microwave oven, otherwise the water might invade
the electric parts and that can cause a short circuit or
electric shock.
5.4. Part replacement
When troubleshooting any part or component is to be replaced,
always ensure that the power cord is unplugged from the wall
outlet.
5.5. When the 10A fuse is blown
due to the malfunction of the
short switch
WARNING
When the 10A 240V fuse is blown due to the malfunction of
the short switch, replace all of the components (primary
latch switch, short switch and power relay RY1).
 1. This is mandatory. Refer to “measurements and
adjustments” for the location of these switches.
 2. When replacing the fuse, confirm that it has the
appropriate rating.
 3. When replacing faulty switches, be sure the mounting
tabs are not bent, broken or deficient in their ability to
hold the switches.
5.6. Avoid inserting nails, wire etc.
through any holes in the unit
during operation
Never insert a wire, nail or any other metal object through the
lamp holes on the cavity or any holes or gaps, because such
objects may work as an antenna and cause microwave
leakage.
5.7. Verification after repair
CAUTION
After repair or replacement of parts, make sure that all the water pipes
and tubes are properly connected, otherwise the water might invade
the electric parts and will cause a short circuit or electric shock.
 1. After repair or replacement of parts, make sure that the
screws of the oven, etc. are neither loose or missing.
Microwave energy might leak if screws are not properly
tightened.
 2. Make sure that all electrical connections are tight before
inserting the plug into the wall outlet.
 3. Check for microwave energy leakage.
CAUTION OF MICROWAVE RADIATION LEAKAGE
USE
CAUTION
NOT
TO
BECOME
EXPOSED
TO
RADIATION FROM THE MICROWAVE MAGNETRON OR
OTHER PARTS CONDUCTING MICROWAVE ENERGY.
IMPORTANT NOTICE
 1. The following components have potentials above 2000V
while the appliance is operated.
  • Magnetron
  • High voltage transformer (Located on inverter (U))
  • High voltage diodes (Located on inverter (U))
  • High voltage capacitors (Located on inverter (U))
Pay special attention to these areas.
 2. When the appliance is operated with the door hinges or
magnetron installed incorrectly, the microwave leakage
can exceed more than 5mW/cm
2
. After repair or
exchange, it is very important to check if the magnetron
and the door hinges are correctly installed.
 3. After repair or replacement of parts, make sure that all
the water pipes and tubes are properly connected,
otherwise the water might invade the electric parts and
will cause short circuit even result in electric shock.
5.8. Sharp edges
CAUTION
Please use caution when disassembling or reassembling
internal parts. Some exposed edges may be sharp to the
touch and can cause injury if not handled with care.
5.9. Hot surface
CAUTION
 1. After using steam function, the oven cavity and steam
heater area becomes very hot.
 2. After using bake function, the oven cavity and bake
heater area becomes very hot.
Therefore, extreme care should be taken during servicing.
10
NN-DS596M
CAUTION
To prevent the water from invading the electric parts that can cause a
short circuit or electric shock:
1. Before repair or replacement of parts, ensure to remove the water
tank from microwave oven.
2. Select the "Drain Water" function to drain the water remaining in
the water pipes and tubes into oven drip tray forcibly. (Operating
method: Add 100g of water to the water tank
→ tap “System
cleaning”
once
→ touch "Start" pad → wait the program
finishing
→ empty the drip tray.) Then wipe up the oven cavity.
3. In case the Microwave Oven has no power, the technician should
have a dry cloth available in advance before disassembly. When
pulling out the water tube, elevate the front of the Microwave Oven
at least 1.5” to minimize the amount of water that leaks out. Wipe
up excess water throughly with the dry cloth.
CAUTION
After repair or replacement of parts, make sure that all the water pipes
and tubes are properly connected, otherwise the water might invade
the electric parts and will cause a short circuit or electric shock.
CAUTION
Discharge the high voltage capacitors first to prevent electric
shock.
6.1. Magnetron
 1. Remove 1 screw holding thermistor on magnetron.
 2. Remove 2 screws holding air guide A on magnetron.
 3. Remove 4 screws holding the magnetron.
NOTE:
After replacement of the magnetron, tighten mounting
screws properly in an x pattern, making sure there is no
gap between the waveguide and the magnetron to
prevent microwave leakage.
CAUTION
When replacing the magnetron, be sure the antenna gasket is in
place.
6 DISASSEMBLY AND PARTS REPLACEMENT
PROCEDURE
11
NN-DS596M
6.2. Fan motor
 1. Disconnect 2 connectors from magnetron terminals.
 2. Disconnect 1 grounding connector from reinforcement
bracket A.
 3. Remove 1 screw holding noise filter(U)’s ground wire on the
reinforcement bracket A.
 4. Remove 1 screw holding the reinforcement bracket on the
oven cavity, then remove the reinforcement bracket.
 5. Disconnect 2 connectors from fan motor terminals.
 6. Remove 2 screws holding fan case (U) on the rear plate.
 7. Remove 1 grounding screw on the oven cavity.
 8. Disconnect all of connectors from noise filter (U).
 9. Release 3 catch hooks.
12
NN-DS596M