9.3. Troubleshooting of inverter circuit (U) and magnetron
This oven is programmed with a self diagnostics failure code system which will help for troubleshooting. H95, H97, H98 and H99
are the provided failure codes to indicate magnetron and inverter circuit problem areas. This section explains failure codes of H95,
H97, H98 and H99. First, you must program the DPC into TEST MODE, press Timer/Clock
pad twice
→ Press Start pad once
→ press Micro Power pad once. Program unit for operation. H95, H97, H98, H99 appears in display window a short time after
start button is pressed and there is no microwave oscillation.
Alternate way to troubleshoot oven with AC Ampere meter used
H95, H97, H98, H99 appears in display window a short time after [Start] pad is pressed and no microwave oscillation with AC
Ampere meter used for troubleshooting.
29
NN-DS596M
9.4. Simple way of H.V. Inverter/magnetron troubleshooting
Purpose:
Simple way (3/23 seconds rule) of identifying whether it’s Magnetron, Inverter, or others.
Set-up:
The unit under question is connected through the Ammeter as shown below.
Procedure:
Follow the matrix table below to identify the problem source.
Note:
Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this
procedure.
Power will:
Ammeter reading is:
To do:
Remedy:
Shut off in 23 seconds
after “Start”.
1. Between 0.5A and 1.0A.
Check and repair open magnetron circuit Open magnetron wiring between Inverter
and magnetron terminal.
2. Between 1.0A and 2.0A.
Check continuity of D702 in Inverter PCB.
1. D702 shorted
Replace H.V.Inverter
(F606YBH20GP)
2. D702 is OK
Replace magnetron
Shut off in 3 seconds
after “Start”
1. Less than 0.5A
Check open circuit: Latch Switch, DPC,
Power Relay and CN701
Replace
defective
component(s),
or
correct switch, cables and connectors.
9.5. How to check the semiconductors using an OHM meter
30
NN-DS596M
9.6. H.V. INVERTER MAIN PARTS LIST (F606YBH20GP)
Ref. No.
Part No.
Part Name & Description
Pcs/Set
Remarks
Q701
B1JAEV000003
IGBT
1
C701
ECWHC3B104JA
FILM CAPACITOR
1
0.1µF,1000VDC
C702
ECWF4305N851
FILM CAPACITOR
1
3µF,250VDC
DB701
B0FBBQ000006
RECTIFIER BRIDGE
1
L701
F5020W100AP
CHOKE COIL
1
R702
D0CM562JA002
SAND BAR RESISTOR
1
5.6K
Ω,15W
T701
F609ABA00GP
TRANSFORMER
1
(INCLUDING D701,D702,C706,C707)
D701,D702
B0FBAZ000006
DIODE
2
C706
F0C3F562A002
FILM CAPACITOR
1
5600PF/3KV
C707
F0C3F822A002
FILM CAPACITOR
1
8200PF/3KV
31
NN-DS596M
10 EXPLODED VIEW AND PARTS LIST
10.1. EXPLODED VIEW