6.12. Low heater (Heater AU)
 1. Remove door (U) (Refer to the 6.7).
 2. Remove fan motor (U) (Refer to the 6.2).
 3. Remove magnetron (Refer to the 6.1).
 4. Remove steam heater (Refer to the 6.9).
 5. Remove joint pipe B.
 6. Remove 3 screws, then remove air guide B.
 7. Remove base plate from oven cavity (Refer to the 6.10).
 8. Remove 2 screws holding left & right hinge on oven cavity.
 9. Remove 2 screws holding left heater panel.
 10. Release 3 holders to free the heater lead wire.
 11. Remove 2 screws from lower heater terminals.
 12. Push right heater panel aside and remove the lower heater
assembly from the oven cavity.
 13. Turn over the low heater assembly.
 14. Release 8 hooks to remove lower heater.
21
NN-DS596M
WARNING
1. High voltage is present at the output terminals of the High Voltage
Inverter (U) including aluminum heat sink during any cook cycle.
2. It is neither necessary nor advisable to attempt measurement of the
high voltage.
3. Before touching any oven components, or wiring, always unplug
the power cord and discharge the high voltage capacitors (see page
9).
7.1. Primary, Secondary Latch
Switch interlocks & Power
Relay RL1
 1. Unplug lead connectors to Power Relay RL1 and verify
open circuit of the Power Relay RL1 (1-2) terminals.
 2. Unplug lead connectors to Primary Latch Switch and Door
Switch.
 3. Test the continuity of switches at door opened and closed
positions with ohm meter (low scale).
Normal continuity readings should be as follows.
Door Closed
Door Opened
Primary Latch Switch
0
Ω (Close)
Ω(Open)
Door Switch
0
Ω (Close)
Ω(Open)
Power Relay
Ω (Open)
Ω(Open)
7.2. Short Switch
 1. Unplug lead wires from Inverter Power Supply (U) primary
terminals.
 2. Connect test probes of ohm meter to the disconnected
leads that were connected to Inverter Power Supply (U).
 3. Test the continuity of short switch with door opened and
closed positions using lowest scale of the ohm meter.
Normal continuity readings should be as follows.
Door Opened
Door Closed
0
Ω (Close)
Ω(Open)
7.3. Magnetron
Continuity checks can only indicate an open filament or a
shorted magnetron. To diagnose for an open filament or
shorted magnetron.
 1. Isolate magnetron from the circuit by disconnecting the
leads.
 2. A continuity check across magnetron filament terminals
should indicate one ohm or less.
 3. A continuity check between each filament terminal and
magnetron case should read open.
7 COMPONENT TEST PROCEDURE
22
NN-DS596M
7.4. Inverter power supply (U)
DO NOT try to REPAIR H.V. Inverter power supply (U).
Replace complete H.V. Inverter(U) Unit.
WARNING: HIGH VOLTAGE
Test if failure codes H95, H97 or H98 appear when performing
the following procedure. It is recommended to use an AC line
input current ammeter for testing.
Test 1
 1. With the oven unit’s AC power supply cord is unplugged
from the wall outlet, unplug the 2 pin H.V. connector CN703
from the magnetron tube.
 2. Place 1 liter of water load into oven cavity.
 3. Plug in the oven’s AC power supply cord into outlet.
 4. Program DPC.
 a. Press Timer/Clock
pad twice.
 b. Press Start
pad once.
 c. 
Press Micro Power
pad once.
 5. Program oven at High power for 1 minute and press [Start]
button.
 a. After approximately 23 seconds, oven stops operating.
 b. During
oven
operation,
the
input
current
is
approximately 0.5 to 1A. If both a and b are OK,
proceed to test 2.
INPUT CURRENT
FAILURE CODE
Unplug CN703
0.5 to 1A
Oven stops in 23
seconds after started.
Test 2
Continued from Test 1
 1. Unplug the oven’s AC power supply cord from outlet.
 2. Unplug 3 pin connector CN701. CN703 remains unplugged.
 3. Plug in the oven’s AC power supply cord into outlet.
 4. Program DPC.
 a. Press Timer/Clock
pad twice.
 b. Press Start
pad once.
 c. 
Press Micro Power
pad once.
 5. Program oven at High power for 1 minute and press [Start]
button.
 a. After approximately 3 seconds, oven stops operating.
 b. During
oven
operation,
the
input
current
is
approximately 0.4A.
INPUT CURRENT
FAILURE CODE
Unplug CN701
0.4A
Oven stops in 3
seconds after started.
If both a and b check OK, the Inverter Power Supply (U) can be
determined to be OK.
7.5. Temperature thermistor
The thermistor that is attached to the magnetron detects the
temperature of the magnetron and will stop magnetron
operation when overheating is detected. A normal thermistor´s
resistance is 35K
Ω to 110KΩ for an ambient temperature range
of 10-30 degree C.
If the resistance reading is out of the range stated here, the
thermistor is detective and must be replaced.
It is also possible to display thermistor level by taking the
following steps.
 1. Program the DPC into TEST MODE (Plug-in oven
→ press
Timer/Clock
pad twice
→ press Start pad once → press
Micro Power
pad once).
 2. Program oven at Standing Time for 1 minute and press
[Start] pad.
 3. Press Micro Power
pad 1~5 times, the thermistor level
readings will shown on the display.
The reading across the temperature thermistor should be
as follows.
Press [Micro Power]
pad
THERMISTOR
LEVEL
READING
1 time
OVEN THERMISTOR
12~226
2 times
MAGNETRON THERMISTOR
15~250
3 times
STEAM THERMISTOR
12~226
If the reading is out of the range stated here, the thermistor
is defective and must be replaced.
23
NN-DS596M
8.1. Adjustment of Primary latch
switch, Secondary latch
switch and Short switch.
 1. Mount the Primary latch switch, the Secondary latch switch
and the Short switch to the door hook assembly as shown
in illustration.
NOTE:
No
specific
individual
adjustments
during
installation of the Primary latch switch, Secondary
latch switch or Short switch to the door hook are
required.
 2. When mounting the door hook assembly to the oven
assembly, adjust the door hook assembly by moving it in
the direction of the arrows in the illustration so that the oven
door will not have any play in it. Check for play in the door
by pulling the door assembly. Make sure that the latch keys
move smoothly after adjustment is completed. Completely
tighten the screws holding the door hook assembly to the
oven assembly.
 3. Reconnect the short switch and check the continuity of the
monitor circuit and all latch switches again by following the
component test procedures.
 4. The Primary latch switch must be ON when the space
between upper portion of door A and cavity front plate is
2~4mm, if the door gap is greater than 4mm, the Primary
latch switch must be OFF.
If
alignment
is
poor,
oven
may
not
operate
after
convection/grill use.
8 MEASUREMENTS AND ADJUSTMENTS
24
NN-DS596M
Page of 42