WARNING
1. High voltage is present at the output terminals of the High Voltage
Inverter (U) including aluminum heat sink during any cook cycle.
2. It is neither necessary nor advisable to attempt measurement of the
high voltage.
3. Before touching any oven components, or wiring, always unplug
the power cord and discharge the high voltage capacitors (see page
8).
5.1. Primary, Secondary Latch
Switch interlocks & Power
Relay RY1
 1. Unplug lead connectors to Power Relay RY1 and verify
open circuit of the Power Relay RY1 1-2 terminals.
 2. Unplug lead connectors to Primary Latch Switch and
Secondary Latch Switch.
 3. Test the continuity of switches at door opened and closed
positions with ohm meter (low scale).
Normal continuity readings should be as follows.
Door Closed
Door Opened
Primary Latch Switch
0
Ω (Close)
Ω(Open)
Secondary Latch Switch
0
Ω (Close)
Ω(Open)
Power Relay RY1
Ω (Open)
Ω(Open)
5.2. Short Switch
 1. Unplug lead wires from Inverter Power Supply (U) primary
terminals.
 2. Connect test probes of ohm meter to the disconnected
leads that were connected to Inverter Power Supply (U).
 3. Test the continuity of short switch with door opened and
closed positions using lowest scale of the ohm meter.
Normal continuity readings should be as follows.
Door Opened
Door Closed
0
Ω (Close)
Ω (Open)
5.3. Magnetron
Continuity checks can only indicate an open filament or a
shorted magnetron. To diagnose for an open filament or
shorted magnetron.
 1. Isolate magnetron from the circuit by disconnecting the
leads.
 2. A continuity check across magnetron filament terminals
should indicate one ohm or less.
 3. A continuity check between each filament terminal and
magnetron case should read open.
5.4. key board membrane
(Membrane switch assembly)
Check continuity between switch terminals, by tapping an
appropriate pad on the key board. The contacts assignment of
the respective pads on the key board is as shown in digital
programmer circuit.
5 COMPONENT TEST PROCEDURE
21
NN-DF383B
5.5. Inverter power supply (U)
DO NOT try to REPAIR H.V. Inverter power supply
(U).Replace complete H.V. Inverter(U) Unit.
WARNING: HIGH VOLTAGE
Test if failure codes H95, H97 or H98 appear when performing
the following procedure. It is recommended to use an AC line
input current ammeter for testing.
Test 1
 1. With the oven unit’s AC power supply cord is unplugged
from the wall outlet, unplug the 2 pin H.V. connector CN703
from the magnetron tube.
 2. Place 1 liter of water load into oven cavity.
 3. Plug in the oven’s AC power supply cord into outlet.
 4. Program DPC.
 a. Press Timer/Clock pad twice.
 b. Press Start pad once.
 c. Press Micro Power pad once.
 5. Program oven at High power for 1 minute and press [Start]
pad.
 a. After approximately 23 seconds, oven stops operating.
 b. During
oven
operation,
the
input
current
is
approximately 0.5 to 1A. If both a and b are OK,
proceed to test 2.
INPUT CURRENT
FAILURE CODE
Unplug CN703
0.5 to 1A
Oven stops in 23
seconds after started.
Test 2
Continued from Test 1
 1. Unplug the oven’s AC power supply cord from outlet.
 2. Unplug 3 pin connector CN701. CN703 remains unplugged.
 3. Plug in the oven’s AC power supply cord into outlet.
 4. Program DPC.
 a. Press Timer/Clock pad twice.
 b. Press Start pad once.
 c. Press Micro Power pad once.
 5. Program oven at High power for 1 minute and press [Start]
pad.
 a. After approximately 3 seconds, oven stops operating.
 b. During
oven
operation,
the
input
current
is
approximately 0.4A.
INPUT CURRENT
FAILURE CODE
Unplug CN701
0.4A
Oven stops in 3
seconds after started.
If both a and b check OK, the Inverter Power Supply (U) can be
determined to be OK.
5.6. Temperature thermistor
The thermistor that is attached to the magnetron detects the
temperature of the magnetron and will stop magnetron
operation when overheating is detected. A normal thermistor´s
resistance is 35K
Ω to 110KΩ for an ambient temperature range
of 10-30 degree C.
If the resistance reading is out of the range stated here, the
thermistor is detective and must be replaced.
It is also possible to display thermistor level by taking the
following steps.
 1. Program the DPC into TEST MODE (Plug-in oven
→ press
Timer/Clock pad twice
→ press Start pad once → press
Micro Power pad once).
 2. Program oven at Standing Time for 1 minute and press
[Start] pad.
 3. Press Reheat
twice, the thermistor level reading will
shown on the display.
The normal reading should be in the range of 16-230.
22
NN-DF383B
6.1. Adjustment of Primary latch
switch, Secondary latch
switch and Short switch.
 1. Mount the Primary latch switch, the Secondary latch switch
and the Short switch to the door hook assembly as shown
in illustration.
NOTE:
No
specific
individual
adjustments
during
installation of the Primary latch switch, Secondary
latch switch or Short switch to the door hook are
required.
 2. When mounting the door hook assembly to the oven
assembly, adjust the door hook assembly by moving it in
the direction of the arrows in the illustration so that the oven
door will not have any play in it. Check for play in the door
by pulling the door assembly. Make sure that the latch keys
move smoothly after adjustment is completed. Completely
tighten the screws holding the door hook assembly to the
oven assembly.
 3. Reconnect the short switch and check the continuity of the
monitor circuit and all latch switches again by following the
component test procedures.
 4. The Primary latch switch must be ON when the space
between upper portion of door A and cavity front plate is
2~4mm, if the door gap is greater than 4mm, the Primary
latch switch must be OFF.
If alignment is poor, oven may not operate after
convection/grill use.
6 MEASUREMENTS AND ADJUSTMENTS
23
NN-DF383B
6.2. Measurement of microwave
output
The output power of the magnetron can be determined by
performing IEC standard test procedures. However, due to the
complexity of IEC test procedures, it is recommended to test
the magnetron using the simple method outlined below.
Necessary Equipment:
  • 1 litre beaker
  • Glass thermometer
  • Wrist watch or stopwatch
NOTE:
Check the line voltage under load. Low voltage will
lower the magnetron output. Take the temperature
readings and heating time as accurately as possible.
 1. Fill the beaker with exactly one litre of tap water. Stir the
water using the thermometer and record the water’s
temperature. (recorded as T1).
 2. Place the beaker on the center of glass tray.
Set the oven for High power and heat it for exactly one
minute.
 3. Stir the water again and read the temperature of the water.
(recorded as T2).
 4. The normal temperature rise at High power level for each
model is as shown in table.
TABLE (1L-1min.test)
RATED OUTPUT
TEMPERATURE RISE
1000W
Min.8.5°C
24
NN-DF383B
Page of 41
Display