DOWNLOAD Panasonic NE-1027ZPE / NE-1037ZPE Service Manual ↓ Size: 823.43 KB | Pages: 36 in PDF or view online for FREE

Model
NE-1027ZPE NE-1037ZPE
Pages
36
Size
823.43 KB
Type
PDF
Document
Service Manual
Brand
Device
Home Appliance / MICROWAVE OVEN
File
ne-1027zpe-ne-1037zpe.pdf
Date

Panasonic NE-1027ZPE / NE-1037ZPE Service Manual ▷ View online

CAUTION
1. High voltage is present at the high voltage terminal of the high
voltage transformer during any cook cycle.
2. It is neither necessary nor advisable to attempt measurement of the
high voltage.
3. Before touching any oven components, or wiring, always unplug
the oven from its power source and discharge the high voltage
capacitor.
7.1. Primary, Secondary Latch
Switch interlocks and Power
Relay RY1
 1. Unplug the lead connectors to Power Relay RY1 and verify
continuity of the power relay RY1 1-2 terminals.
 2. Unplug lead connectors to primary latch switch and
secondary latch switch.
 3. Test the continuity of switches at door opened and closed
positions with ohm meter (low scale).
Normal continuity readings should be as follows.
7.2. Short Switch & Monitor
 1. Unplug lead wires from H.V.transformer primary terminals.
 2. Connect test probes of ohm meter to the disconnected
leads of the H.V. transformer.
 3. Test the continuity of short switch with door opened and
closed positions using lowest scale of the ohm meter.
Normal continuity readings should be as follows.
7.3. High voltage transformer
 1. Remove connectors from the transformer terminals and
check continuity.
 2. Normal (cold) resistance readings should be as follows:
Secondary winding........................... Approx. 60
Ω~120 Ω
Filament winding.............................. Approx. 0
Ω
Primary winding................................. Approx. 0
Ω ~2 Ω
7.4. High voltage capacitor
 1. Check continuity of capacitor with meter on highest OHM
scale.
 2. A normal capacitor will show continuity for a short time, and
then indicate 9M
Ω once the capacitor is charged.
 3. A shorted capacitor will show continuous continuity.
 4. An open capacitor will show constant 9M
Ω.
 5. Resistance between each terminal and chassis should be
infinite.
7.5. Magnetron
Continuity checks can only indicate an open filament or a
shorted magnetron. To diagnose for an open filament or
shorted magnetron:
 1. Isolate magnetron from the circuit by disconnecting the
leads.
 2. A continuity check across magnetron filament terminals
should indicate one ohm or less.
 3. A continuity check between each filament terminal and
magnetron case should read open.
7 COMPONENT TEST PROCEDURE
17
NE-1027 / NE-1037
7.6. Variable power controller
(NE-1027)
 1. Isolate variable power switch from the circuit by
disconnecting 2 leads.
 2. In order to check if variable power controller is operating
normally, follow the test procedures below.
 a. Select any power other than "900" and start the oven.
 b. Check continuity between both terminals of the variable
power switch.
 c. Variable power controller (timer and variable power
switch) is working properly if the ohm meter reads open
and 0 ohm within 26 ± 2 seconds interval as shown in
Table on description of operating sequence.
7.7. Diode
 1. Isolate the diode from the circuit by disconnecting the leads.
 2. With the ohmmeter set on the highest resistance scale,
measure the resistance across the diode terminals.
Reverse the meter leads and again observe the resistance
reading. Meter with 6V, 9V or higher voltage batteries
should be used to check the front-to-back resistance of the
diode, otherwise an infinite resistance may be read in both
directions.
A normal diode´s resistance will be infinite in one direction
and several hundred k
Ω in the other direction.
7.8. Protector diode
 1. Isolate the protector diode assembly from the circuit by
disconnecting its leads.
 2. With the ohmmeter set on the highest resistance scale,
measure the resistance across the protector diode
terminals.
Reverse the meter leads and again observe the resistance
reading. A normal protector diode´s resistance will be
infinite in both directions.
It is faulty if it shows continuity in one or both directions.
7.9. Membrane key board
(Membrane switch assembly)
(NE-1037)
Check continuity between switch terminals, by tapping an
appropriate pad on the key board. The contacts assignment of
the respective pads on the key board is as shown in digital
programmer circuit.
7.10. Temp sensor
(Thermal protector) (NE-1037)
A temp sensor is mounted on exhaust guide. Its purpose is to
automatically shut off the oven in case the cavity overheats for
any reason.
The thermal protector will operate at 257°F (125°C).
The device is connected to the D.P.C. on touch control models.
When the thermal protector exceeds its temperature it will turn
off the power to oven cavity and display wil go to reset mode.
The cooking program can be reset after cool-down.
18
NE-1027 / NE-1037
8.1. Adjustment of primary latch
switch, secondary latch switch
and short switch.
 1. Mount the Primary latch switch, the Secondary latch switch
and the Short switch to the door hook assembly as shown
in illustration.
NOTE:
No
specific
individual
adjustments
during
installation of the Primary latch switch, Secondary
latch switch or Short switch to the door hook are
required.
 2. When mounting the door hook assembly to the oven
assembly, adjust the door hook assembly by moving it in
the direction of the arrows in the illustration so that the oven
door will not have any play in it. Check for play in the door
by pulling the door assembly. Make sure that the latch keys
move smoothly after adjustment is completed. Completely
tighten the screws holding the door hook assembly to the
oven assembly.
 3. Reconnect the short switch and check the continuity of the
monitor circuit and all latch switches again by following the
component test procedures.
8.2. Measurement of microwave
output
The output power of the magnetron can be determined by
performing IEC standard test procedures. However, due to the
complexity of IEC test procedures, it is recommended to test
the magnetron using the simple method outlined below.
Necessary Equipment:
  • 1 litre beaker
  • Glass thermometer
  • Wrist watch or stopwatch
NOTE:
Check the line voltage under load. Low voltage will
lower the magnetron output. Take the temperature
readings and heating time as accurately as possible.
 1. Fill the beaker with exactly one litre of tap water. Stir the
water using the thermometer and record the water’s
temperature. (recorded as T1).
 2. Place the beaker on the center of glass tray.
Set the oven for High power and heat it for exactly one
minute.
 3. Stir the water again and read the temperature of the water.
(recorded as T2).
 4. The normal temperature rise at High power level for each
model is as shown in table.
TABLE (1L-1min.test)
RATED OUTPUT
TEMPERATURE RISE
1000W
Min.8.5°C
8 MEASUREMENTS AND ADJUSTMENTS
19
NE-1027 / NE-1037
9 TROUBLESHOOTING GUIDE
9.1. NE-1027
CAUTION
1. Check grounding before checking for trouble.
2. Be cafeful of the high voltage circuit.
3. Discharge high voltage capacitor.
4. When checking the continuity of the switches or the high voltage transformer, disconnect one lead wire from these parts and then check
continuity with the AC plug removed. To do otherwise may result in a false reading or damage to your meter.
When disconnecting a plastic connector from a terminal, you must hold the plastic connector instead of the lead wire and then disconnect it,
otherwise lead wire may be damaged or the connector cannot by removed.
First of all operate the microwave oven following the correct operating procedures in order to find the exact cause of any trouble.
9.1.1. [TROUBLE 1] Oven does not start cooking
SYMPTOM
CAUSE
CORRECTIONS
1. Oven is dead.
1. Open or loose lead wire harness
Fuses is OK.
2. Open thermal cutout (Magnetron)(Oven)
Check fan motor when thermal cutout is defective.
2. No microwave oscillation.
1. Off-alignment of latch switches
Adjust door and latch switches.
Other operation is OK.
2. Defective secondary latch switch (SW2)
3. Open or loose wiring of secondary latch switch,
vari-power switch and micro select switch
4. Defective variable power switch (SW7)
Refer to component test procedure.
5. Open or loose connection of high voltage
circuit especially magnetron filament circuit
NOTE: Large contact resistance will bring lower
magnetron filament voltage and causing
magnetron to lower output and/or intermittent
oscillation.
6. Defective high voltage component
H.V. Transformer
H.V. Capacitor
H.V. Diode
Magnetron
Check
high
voltage
component
according
to
component test procedure and replace if it is defective.
20
NE-1027 / NE-1037
Page of 36
Display