DOWNLOAD Panasonic NC-DG3000WTS Service Manual ↓ Size: 3.91 MB | Pages: 31 in PDF or view online for FREE

Model
NC-DG3000WTS
Pages
31
Size
3.91 MB
Type
PDF
Document
Simplified Service Manual
Brand
Device
Home Appliance / ELECTRIC THERMO POT
File
nc-dg3000wts.pdf
Date

Panasonic NC-DG3000WTS Simplified Service Manual ▷ View online

9
4.4.
Troublesshooting
10
5 Troubleshooting Guide
Please follow check operating detail bellow, before start to check the problems.
LED symbol for this instruction show as below.
5.1.
Thermo pot performance test mode
5.1.1.
The body test mode 
How to operate
1. Pour water into the container.
2. Press “Timer” button and “Long Boil / Reboil” button and
“Select / Cleaning(Press 3s)” button, all together, and
then supply electric power.
Instructions
• LCD : Light (all lighted)
• LED : ON (Lock / Unlock)
• Heater : OFF
• Others : When it passes for about 30 seconds in the state
made nothing, "The body test mode" releases and shifts to
"Usual mode".
5.1.2.
Operation of Thermo pot performance test mode
1. Pour water into the container.
Press “Timer” button and  “Long Boil / Reboil” button and  “Select / Cleaning(Press 3s)” button, all together, and then supply
electric power.
Start Thermo pot performance test mode when turn on with “Timer” button and “Long Boil / Reboil” button and  “Select /
Cleaning(Press 3s)” button on.
Operate reset action after 30 seconds.
Button
Motor
LED
LCD
Long Boil / 
Reboil
VIP
Keep Warm
Lock / Unlock
“Long Boil / Reboil”
+
“Timer”
+
“Select / Cleaning(Press 3s)”
OFF
OFF
OFF
ON
Attention
• When “Pour Out” button is pressed, simultaneously with “VIP Keep Warm” LED flashing and off hot water comes out.
LCD indication also changes.
“Long Boil / Reboil” LED
• When the water temperature is more than 47 deg, “Long Boil / Reboil” LED ON.
• When the water temperature is less than 47 deg, “Long Boil / Reboil” LED OFF.
11
2. Press the “Pour Out” button.
3. Press the “Lock / Unlock” button.
Button
Motor
LED
LCD
Long Boil / 
Reboil
VIP
Keep Warm
Lock / Unlock
“Pour Out”
ON
OFF
ON
(Flashing)
OFF
Attention
• When “Pour Out” button is pressed, hot water comes out.
“Long Boil / Reboil” LED
• When the water temperature is more than 47 deg, “Long Boil / Reboil” LED ON.
• When the water temperature is less than 47 deg, “Long Boil / Reboil” LED OFF.
Button
Motor
LED
LCD
Long Boil / 
Reboil
VIP
Keep Warm
Lock / Unlock
“Lock / Unlock”
OFF
OFF
ON
(It flashes on and off alter-
nately)
“Long Boil / Reboil” LED
• When the water temperature is more than 47 deg, “Long Boil / Reboil” LED ON.
• When the water temperature is less than 47 deg, “Long Boil / Reboil” LED OFF.
12
5.2.
Check for thermo pot performance
5.2.1.
Boiling and Keep warm test
How to operate
1. Pour water into the container. (up to MAX line)
2. Supply with electric power.
3. Press “Select Cleaning(Press 3s)” button to set 90 keep
warm.
“Select Cleaning(Press 3s)” button:90-80-70-98-90---
Instructions
1. “Long boil / Reboil” LED will be lighted and start to boil
water. (LCD monitor will display temperature in every 5
degree)
2. If water wells up, “VIP Keep  Warm” LED light on and
breaks reshuffling in warming.(warming is in a state)
3. Time required to boil water
・ DG3000 : approx. 27 min.
( Amount of water : Maximum Room temperature : 20deg
Initial keep-warm setting: 90 )
4. If water wells up, and the temperature will drop to approx-
imately 90deg and switches to keep-warm function auto-
matically.(DG3000 : approx. 2.4-4.5 hours)
5.2.2.
Reboiling and Keep warm test
How to operate
1. Set Keep Warm.
2. Press “Long Boil
 / Reboil” button once.
Instructions
1. “Long Boil/Reboil”
 LED turns on and begins a kettle.
2. If water wells up, and “VIP Keep Warm” LED light on and
breaks reshuffling in warming.(warming is in a state)
3. Time required for the reboil procedure
・ From 98 keep-warm : approx. 1-3 min.
• From 90 keep-warm : approx. 
4-7 min.
・ From 80 keep-warm : approx. 6-11 min.
・ From 70 keep-warm : approx. 7-12.5 min.
(Amount of water : Maximum Room temperature : 20deg)
4. Time required to reach the settled keep warm tempera-
ture
• 90
---98 keep-warm : approx. 7-16 min.
・ 90---80 keep-warm : approx. 2-2.5 hours
• 90---70 keep-warm : approx. 3.5-4.5 hours
(Amount of water: Maximum Room temperature: 20deg
Initial keep-warm setting: 90)
5.2.3.
Pour out test 
How to operate
1. Pour water into the container. (up to MAX line)
2. Supply with electric power.
3. Press “Lock / Unlock” button.
4. Press “Pour Out” button. (Continuation)
Instructions
1.
“Lock / Unlock” LED turns on when it pushes the “Lock /
Unlock” button, and water flows from a beak when it
pushes the hot water supply button.
Page of 31
Display

Click on the first or last page to see other NC-DG3000WTS service manuals if exist.