Panasonic UF-490 / UF-4000 / UF-4100 Service Manual ▷ View online
109
4.6.3.
Dialing Problems
START
END
No
Yes
Does the unit proceed to
Phase B?
Phase B?
1. Set documents on the ADF correctly.
4. Refer to Sect. 4.6.
3. The called party is busy.
2. Check the telephone line connection.
Are you using One-Touch
or ABBR dialing?
or ABBR dialing?
Are you using direct dialing?
No
Yes
Check the registered telephone number.
Is the Monitor Volume
too loud or too low?
too loud or too low?
No
Yes
Check the dialed telephone number.
No
Yes
Adjust the monitor volume by pressing the
"/\" or "\/" curser keys.
"/\" or "\/" curser keys.
110
4.6.4.
Transmission Problems
START
END
Yes
No
Does the ID display?
1. No ID function at the remote unit.
2. The ID is not set for the remote unit.
2. The ID is not set for the remote unit.
Does the Verification Stamp
operate? (Except for USA
and Canada)
operate? (Except for USA
and Canada)
Is the copy quality OK?
Yes
No
No
1. Set "STAMP=ON"
2. Check CN13 (SC PCB).
3. Replace the Stamp Solenoid.
4. Replace the SC PCB.
2. Check CN13 (SC PCB).
3. Replace the Stamp Solenoid.
4. Replace the SC PCB.
Any other problems?
Yes
No
Make a copy and refer to Sect. 4.4.17
Yes
See Sect. 4.3 (Troubleshooting with the
Information Codes).
Information Codes).
111
4.6.5.
Reception Problems
START
END
Yes
No
Does the machine answer
the Ringing signal?
the Ringing signal?
1. Check that the reception mode is set to
"FAX" (and Out LED turns on For USA /
Canada).
2. Check that all covers are closed firmly.
3. Check the telephone line connection.
4. Check the Ringer Timing or DRD setting.
5. Check the recording paper path.
6. Replace the SC PCB.
"FAX" (and Out LED turns on For USA /
Canada).
2. Check that all covers are closed firmly.
3. Check the telephone line connection.
4. Check the Ringer Timing or DRD setting.
5. Check the recording paper path.
6. Replace the SC PCB.
Is the received copy OK?
Any other problems?
Yes
No
Make a copy and refer to Sect. 4.4.14.
Yes
No
See Sect. 4.3 (Troubleshooting with the
Information Codes).
Information Codes).
112
4.6.6.
Polling Problems
START
END
Yes
No
Is Polling reception OK?
1. Set the same polling password as the other party
is using.
2. Check the password of the remote unit.
is using.
2. Check the password of the remote unit.
Any other problems?
Yes
No
See Sect. 4.3
(Troubleshooting with the Information Codes).
(Troubleshooting with the Information Codes).
Click on the first or last page to see other UF-490 / UF-4000 / UF-4100 service manuals if exist.