Panasonic KX-FLB883RU Service Manual ▷ View online

117
KX-FLB883RU
12.3.6. CALL SERVICE Troubleshooting Guide
Call Service related error is most frequent.
Call Service 1 ----- Polygon doesn’t rotate......... Refer to LSU (Laser Scanning Unit) Section (P.42).
• First, listen to the sound. If rotation sound isn't heard, check 24V line, POLON signal and POLCLK signal. If even a little of sound
is heard, check XREADY signal.
Call Service 2 ----- Laser isn't output.......... Refer to LSU (Laser Scanning Unit) Section (P.42)
• This can be judged only by referring to signal. Check 5V line, XHSYNC, XAPC, XVIDEO, XLDON.
Call Service 3 ----- Detection of fixing temperature.......... Refer to Heat Lamp Control Circuit (P.58)
• *Service mode *655 tells the detection number and 3 latest temperatures of the thermistor. The detection point of the Call Ser-
vice 3 and the thermistor temperature is displayed. Maximum 3 latest temperatures are displayed showing the newest on the left.
[AABB CCDD EEFF] AA, CC and EE show the detection points and BB, DD and FF show their temperature detection points.
00: CALL SERVICE 3 was not occurred.
01: means that the value of AD did not increased by 6 steps or more within 10 sec soon after the heater was turned ON. (ther-
mistor’s open detection)
02: means that it did not reach the first stabilizing temperature (160
°C: 5Bh) within 50 seconds.
03: means that it did not reach the second stabilizing temperature (185
°C: 3Ch) within 70 seconds after reaching the first stabiliz-
ing temperature (160
°C: 5Bh).
04: means that it dropped to 165
°C: 61h (-40 deg) or below by the temperature control after reaching the second stabilizing tem-
perature (185
°C: 3Ch).
05: means that it did not reach the first stabilizing temperature (160
°C: 5Bh) within 30 seconds from detection temperature 1
(70
°C: D8h).
06: means that it became 235
°C: 2Ah or over during printing.
07: means that during printing the short of the thermistor (AD: 00h) was detected.
08: means that the thermistor’s short (AD: 00h) and open (AD: FFh or over) were detected.
<Note>
Call Service 4 ----- Rotation of Fan.......... Refer to FAN Motor Section (P.39)
• Connector isn’t inserted firmly, dust is caught in and the fan is broken.
• Rotation of the Fan can be confirmed by following Test Mode.
Service mode *677
:1... Normal operation (default)
:2... 
FAN 1
 (
Right Fan) ON (High speed)
:3... 
FAN 1
 (Right Fan) ON (Low speed)
:4... 
FAN 
2
 (Left Fan) ON (High speed)
:5... 
FAN 
(Left Fan) ON (Low speed)
Call service 5 ----- Rotation of Engine motor.......... Refer to Motor Drive Section (P.32)
• Engine motor’s rotation detection signal LD did not become Low within rated speed ±6.25%.
• Service mode *556: the operation of Main Motor can be checked by pressing 0 and SET buttons.
Call service 6 ----- Detection of Charger error.......... Refer to the HVPS (High Voltage Power Supply) Section (P.56)
• Breaking of charger’s wire of Drum Unit and/or loose connection of High voltage terminals (CHRG, GRID). 
• First, replace the Drum unit even so, it doesn’t function check the high voltage power supply.
* As for Call Service 1, 2, 4, 5 and 6, turn the power OFF then ON to restart.
Once “CALL SERVICE3” is displayed, The “CALL SERVICE3” does not disappear until the Factory Setup or Service Function #529 is 
executed.
Therefore Service Function #529 should be executed before the confirmation, and #529 should be done after the countermeasure.
118
KX-FLB883RU
12.3.6.1. CALL SERVICE 1
"CALL SERVICE 1" means that the polygon motor inside the LSU does not rotate.
The rotation of the polygon motor is detected by IC300-R32pin (XREADY).
119
KX-FLB883RU
12.3.6.2. CALL SERVICE 2
"CALL SERVICE 2" means that the synchronous signal out of the LSU cannot be detected.
The synchronous signal out of the LSU is detected by IC300-T31pin. (XHSYNC)
Note:
As for the "Pulse" waveform of the above flow chart, see the timing chart.
120
KX-FLB883RU
12.3.6.3. CALL SERVICE 3
"CALL SERVICE 3" means that the temperature of the fuser does not rise up to or exceed a constant temperature.
The temperature is monitored with the thermistor inside the fuser and detected with the voltage input into IC300-U34pin.
* When Call Service 3 is occurred, the cause can be distinguished by service mode  655.
Refer to P.117 for details.
Page of 127
Display

Click on the first or last page to see other KX-FLB883RU service manuals if exist.