7.2. (VHS) Self-Diagnosis and Special Mode Setting
7.2.1. (VHS) Special Modes Setting
Note:
Set DRIVE SELECT to VHS.
Item
FL display
Key operation
Mode name
Description
Front Key
Tracking Center
Tape Tracking is adjusted to center
FIX position.
No display.
During PLAYBACK, press [CH UP]
and
[CH
DOWN]
keys
simultaneously.
VHS Service Mode
In order to make service easy, a part
of
inside
information
of
a
microprocessor is displayed on FIP.
*Details are described in "7.2.2.
(VHS) Service Mode"
.
Press [STOP], and [EJECT] keys
simultaneously for 3 seconds when
power is off.
Releasing EXT LINK and
Timer Program
Releasing Continuation EXT LINK
and Timer Program
No display.
While in EXT LINK and Timer REC
mode, press [STOP] key for 3
seconds.
Eject
Ejecting Cassette Tape
No display.
While in other than Timer REC mode,
press [STOP] key for 3 seconds or
press [STOP] key of the Remote
Controller for 3 seconds.
25
DMR-EZ47VEB
7.2.2. (VHS) Service Modes
 1. Set DRIVE SELECT to VHS.
 2. When power is off, press [STOP] and [EJECT] keys simultaneously for 3 seconds to into Service Mode.
 3. In service mode, press [STOP] and [EJECT] keys simultaneously to add Service Number.
Service
Mode
Number
Contents
Contents of Indication on minute
Contents of Indication on second
Remarks
0
Indication for the
inner
data
of
IC6001
VHS mode
(Real time)
Process number of the mechanism
movement
(Real time)
1
Indication for the
inner
data
of
IC6001
Tape
beginning
and
ending
detection data (Real time)
Key code
(Real time)
00: Both tape beginning and ending
have not been detected
01: Tape ending is detecting now
02: Tape beginning is detecting now
03: Both tape beginning and ending
are detecting now
Indicate the receiving code when the
key of VCR or remote controller
being operated.
2
Indication for the
inner
data
of
IC6001
Mechanism position (Real time)
Ordering for the Motors (Real time) The
following
functions
are
prohibited to operate the mechanism
without cassette tape.
lTape
beginning
and
ending
detection.
lReel lock detection
lTape detection and tape position
detection
Press the EJET key for over 3
seconds in this mode, and then the
VCR is shifted into the special
modes, such as PG Adjustment,
Model Code Setting, and so on.
The orders for the motors are as
follows.
0L: EJECT position
02: DOWN position
03: RREW position
04: LOAD position
05: REV position
06: PLAY position
07: POFF position
08: STOP_R position
09: STOP_F position
0 - : FF/REW position
0_ : Intermediate between each
positions
0*, 2*: CYL off,
CAP off
1*: CYL off,
CAP on (fwd)
3*: CYL off,
CAP on (rev)
8*, A*: CYL on,
CAP off
9*: CYL on,
CAP on (fwd)
B*: CYL on,
CAP on (rev)
*0: Motor off
*1: Loading
*2: Unloading
*3: Break (Load + Unload)
3
Self-diagnosis
history (1st)
1st history of error number
"- -" is displayed.
4
Self-diagnosis
history (2nd)
2nd history of error number
"- -" is displayed
5
Self-diagnosis
history (3rd)
3rd history of error number
"- -" is displayed
6
Indication for the
inner
data
of
IC6001
Servo data (4 digits)
(Real time)
7
Manual mechanism
operation
Mechanism position (Real time)
Ordering for the Motors
Press the following key;
PLAY key : Loading
STOP key : Unloading
0L: EJECT position
02: DOWN position
03: RREW position
04: LOAD position
05: REV position
06: PLAY position
07: POFF position
08: STOP_R position
09: STOP_F position
0 - : FF/REW position
0 _: Intermediate between each
positions
0*, 2*: CYL off,
CAP off
1*: CYL off,
CAP on (fwd)
3*: CYL off,
CAP on (rev)
8*, A*: CYL on,
CAP off
9*: CYL on,
CAP on (fwd)
B*: CYL on,
CAP on (rev)
*0: Motor off
*1: Loading
*2: Unloading
*3: Break (Load + Unload)
26
DMR-EZ47VEB
7.2.3. (VHS) Self-Diagnosis Functions
This model has a self-diagnosis. If the VHS section detects trouble during installation or during use, the power is automatically
turned off or become power-save mode and it is memorized into the EEPROM (IC9703) as error code of two-digit number. It´s
memorized error code can be displayed in "second" display portion (the last 2 digits of the FIP) by placing the unit is Service Mode
Number 2 when turning on Service Information Display as for example "01" or "02" etc as below. If a second error occurs, the most
recent error will be memorized and can be displayed in Service Mode Number 2. It can be memorized until 3 self-diagnosis histories
in maximum.
In order to erase the memorized error code, press STOP and EJECT buttons on the Front Panel simultaneously over 5 seconds
during turning on Service Information Display mode.
7.2.3.1. Memory of the self-diagnosis history
*This is effective only in Service Mode 3, 4, 5.
7.2.3.1.1. Error Numbers at a glance
Memory No. (Error Code)
Reason
01
The cylinder could not be started. (Error of the cylinder or the cylinder driver.)
02
The CAP FG could not be detected.
03
Mechanism lock during without the unloading and the cassette-up.
04
Mechanism lock during unloading
05
S-reel pulse cannot be detected during unloading. (Error of the S-reel circuit or the Capstan circuit)
06
Mechanism lock during the Cassette-up.
09
Communication error between VHS Microprocessor (IC6001) and Timer Microprocessor (IC9701).
15
S-reel pulse cannot be detected when a cassette tape is inserted.
(Error of the S-reel circuit or the Capstan circuit)
16
Detection of the Cylinder lock during the constant rotation
17
Detection of S-reel lock during the constant tape running
18
Detection of T-reel lock during the constant tape running
2*
Refer to following Note
An error while the PG Automatic Adjustment
80
An exceptional ejection depends on a accidental error
Note:
2* is as follows.
20
NG1 in the PG Shifter Automatic Adjustment (The cylinder rotation is unstable during the automatic adjustment.)
21
NG2 in the PG Shifter Automatic Adjustment (The vertical sync signal is lacked while over 5 seconds on the alignment tape.)
22
NG3 in the PG Shifter Automatic Adjustment (The installing position of Heads to the cylinder is our of specification.
23
NG4 in the PG Shifter Automatic Adjustment (The servo is not locked to the cylinder for more than 10 sec.)
7.2.3.1.2. Memory for the self-diagnosis history
 1. The self-diagnosis result is memorized the state of the moment of detecting.
 2. There are the histories from number 1 to number 3.
 3. The latest error is memorized on history number 1, and then the old histories are shifted to the history number 2 and 3.
The error code memorized in the history number 2 and 3 is over-written by shift.
 4. If the latest error is the same with the history number 1 (2nd-latest), it is not memorized.
(The same error code is not memorized in succession)
7.2.3.1.3. Clear for the self-diagnosis history
 1. Press FF and EJECT buttons on the VCR simultaneously over 5 seconds during turning on Service Information Display mode.
27
DMR-EZ47VEB
7.2.3.1.4. Indication of the self-diagnosis history.
The self-diagnosis histories can be indicated on the FIP with Service Mode number 3 to 5.
The procedure of service mode setting and indication format are the same as usual.
28