 1. Turn off the power and pull out AC cord.
 2. Remove the Top Case.
 3. Push in SLIDE CAM by Eject Pin(JSJ0484) or minus screw driver (small) to eject tray slightly.
 4. Push out Tray by Eject Pin (JZS0484) or minus screw driver (small).
13
DMR-EZ47VEB
6.2. (VHS) Removing Cassette
Tape manually
When the cassette tape could not be uninstalled from an
electrical malfunction, there are 2 ways to remove a cassette
tape.
6.2.1. (VHS) Removal by compulsory
unloading.
If Service Mode can be activated when the power can not be
turned on, this operation is able.
 1. Press [STOP] and [EJECT] button simultaneously for more
than 3 seconds to turn the unit in VHS service mode.
 2. Press [STOP] and [EJECT] button simultaneously 7 times
to turn the unit in VHS Service Mode “7”.
 3. Press [STOP] button in order to unload the mechanism.
(Pay attention to tape slack)
Service Mode Display:
7 ** ** (STOP)
® 7 0L ** (EJECT)
6.2.2. (VHS) Removal by manual
operation by rotating the Loading
Motor with the batteries.
 1. Disconnect the AC plug, and remove the Top Panel and the
Front Panel by referring to the Disassembly Procedures.
 2. Connect three batteries (1.5V spec.) to the Loading Motor
in series for supplying 4.5V to rotate the Loading Motor as
shown below.
 3. Stop unloading just before unloading will be completed as
shown below, and then the tape becomes slack as shown
below.
 4. Rotate the S-Reel by a small minus screwdriver to remove
the slack tape as shown below.
 5. Then unload again to remove the cassette tape as shown
below.
14
DMR-EZ47VEB
6.2.3. (VHS) Take out Cassette
Tapemanually after removing the
mechanism
 1. Disconnect the AC plug, and remove the Top Panel, Front
Panel and the Mechanism by referring to "9 Assembling
and Disassembling"
 2. Remove the Screw and remove the Loading Motor as
shown below.
 3. Rotate the Main Cam Gear counter-clockwise until just
before the unloading will be completed as shown below. .
 4. Rotate the Capstan Motor clockwise to remove the slack
tape as shown below.
 5. Rotate the Main Cam Gear counter-clockwise again to
remove the cassette-tape as shown below.
 6. Attach Loading Motor and tighten the screw.
 7. Set the Position Switch to EJECT POSITION certainly and
attach the mechanism to chassis as shown below.
15
DMR-EZ47VEB
7 Service Mode
7.1. (DVD) Self-Diagnosis and Special Mode Setting
7.1.1. (DVD) Self-Diagnosis Functions
Self-Diagnosis Function provides information for errors to service personnel by “Self-Diagnosis Display” when any error has
occurred.
U**, H** and F** are stored in memory and held.
You can check latest error code by transmitting [0] [1] of Remote Controller in Service Mode.
Automatic Display on FL will be cancelled when the power is turned off or AC input is turned off during self-diagnosis display is ON.
Error Code
Diagnosis contents
Description
Monitor Display
Automatic FL display
U30
Remote control code error
Display appears when main unit and remote
controller codes are not matched.
No display
“*” is remote controller code of the
main unit.
Display for 5 seconds.
U59
Abnormal inner temperature
detected
Display appears when internal temperature of
deck reaches limit temperature.
The power is turned off forcibly.
For 30 minutes after this, all key entries are
disabled. (Fan motor operates at the highest
speed for the first 5 minutes. For the
remaining 25 minutes, fan motor is also
stopped.) The event is saved in memory as
well.
No display
U59 is displayed for 30 minutes.
U61
The unit is carrying out its
recovery process.
No display
U71
HDMI incompatible error
(HDCP incompatible)
Display this error when the equipment
(compatible with DVI such as TV, amplifier
etc.) connected to the unit by HDMI is
incompatible with HDCP.
*HDCP=High-bandwidth
Digital
Content
Protection
No display
U72
HDMI connection error
(communication error)
This error is displayed when there are any
communication problems with the unit and the
equipments (TV, amplifier etc.) connected to
the unit by HDMI. (or when there is a problem
with the HDMI cable)
U72 display disappears when
error has been solved by Power
OFF/ON of connecting equipment
or by inserting/removing of HDMI
cable.
U73
HDMI connection error
(authentication error)
When authentication error occurs while the
equipments (TV, amplifier etc.) are connected
by HDMI. (or when there is a problem with the
HDMI cable)
No display
U73 display disappears when
error has been solved by Power
OFF/ON of connecting equipment
or by inserting/removing of HDMI
cable.
U80
ST Microprocessor
Communication Error on Timer
Bus
Display appears when ST Microprocessor
Communication Error on Timer Bus occurs.
No display
U80 is displayed till Power Key is
pressed.
U81
ST Microprocessor
Communication Error on UART
Display appears when ST Microprocessor
Communication Error on DART occurs.
No display
U81 is displayed till Power Key is
pressed.
16
DMR-EZ47VEB
Page of 127
Display

Click on the first or last page to see other DMR-EZ47VEB service manuals if exist.