Panasonic DMP-B200P / DMP-B200PC Service Manual ▷ View online
21
8 Service Fixture & Tools
Part No.
Uses
Pcs
Interchangeability with Old Fixture Tools
-----
New CD-R disc
1
RFKZ0558(5Pin)+ RFKZ0559
Extension cable + connector
(Traverse Unit-Main P.C.B.)
(Traverse Unit-Main P.C.B.)
1
Same as B100 series
RFKZ0560(8Pin) + RFKZ0561
Extension cable + connector
(Traverse Unit-Main P.C.B.)
(Traverse Unit-Main P.C.B.)
1
Same as B100 series
RFKZ0562(6Pin)+ RFKZ0563
Extension cable + P.C.B.
(PC-Main P.C.B. (P51601)
(PC-Main P.C.B. (P51601)
1
Same as B100 series
RFKZ0139
Serial Cable (PC-Main P.C.B. (P51601)/6pin)
1
Same as B100 series
RFKZ03D01KS
Lead Free Solder (0.3mm/100g Reel)
Sharing with EH55/EH75V/XP10/XW30 Series
RFKZ06D01KS
Lead Free Solder (0.6mm/100g Reel)
Sharing with EH55/EH75V/XP10/XW30 Series
RFKZ10D01KS
Lead Free Solder (1.0mm/100g Reel)
Sharing with EH55/EH75V/XP10/XW30 Series
RFKZ0316
Lead Free Solder with Low Melting Point
for Unsolder (50g)
for Unsolder (50g)
Sharing with EH55/EH75V/XP10/XW30 Series
RFKZ0328
Flux
Sharing with EH55/EH75V/XP10/XW30 Series
22
9 Disassembly and Assembly Instructions
9.1.
Disassembly Flow Chart
23
9.2.
P.C.B. location
9.3.
Main cabinet unit
<Removing battery pack>
Release the lock lever and remove the battery pack in the
direction of the arrow.
direction of the arrow.
1. Remove the 2 foot rubbers.
2. Remove the 13 screws .
3. Release the latches and remove the bottom cabinet.
24
9.4.
Traverse Unit
NOTE:
The countermeasure against static electricity is necessary
when servicing the surrounding of traverse unit.
Moreover, the traverse unit is the precision optical part.
Take care not to touch surrounding of the lens and not to
shock to the traverse unit.
when servicing the surrounding of traverse unit.
Moreover, the traverse unit is the precision optical part.
Take care not to touch surrounding of the lens and not to
shock to the traverse unit.
1. Pull out the P55010(FFC) and the P55011(FFC).
2. Release the connector and latches, pull out the
P55006 (FFC), and then remove the traverse unit.
9.5.
Main P.C.B.
1. Remove the connector and the flexible cable.
2. Pull out the P57002(FFC).
2. Pull out the P57002(FFC).
3. Remove the 4 screws and remove the main P.C.B. with
BAT-CONNECTOR P.C.B. and HP P.C.B..
9.6.
Operation P.C.B.
1. Remove the 5 screws and remove the Operation P.C.B..
9.7.
Disc cover
1. Remove the screw and the STOPER JIKUUKE.